Skip to content
    Talk to an Expert
    Talk to an Expert

      Exit Devices & Panic Bars

      Talk To An Expert

      Panic Hardware for Wide and Narrow Stile Doors

      Panic hardware lets anyone leave a building with one push, and on a fire-rated door it also has to keep that door latched in a fire. PDQ makes exit devices for wide stile doors, narrow stile storefront doors, and value-driven projects, in rim, vertical rod, and mortise styles. Every working device is UL 305 listed for panic use, most are fire listed up to 3 hours, and the 6300 and 6400 Series are made in the USA with a 10-year limited warranty.

      Exit Devices by Series

      Start with the door. Stile width decides the series, then the opening decides the device type: rim for single doors or pairs with a mullion, vertical rod for pairs without one.

      PDQ 6300R wide stile rim exit device
      Wide Stile

      6300 Series

      Our most complete exit device line, for hollow metal and wood doors with at least a 3-1/2" stile.

      • Fire listed up to 3 hours on rim and vertical rod models; the mortise device is listed to 90 minutes
      • Electrified options plus 6W99 and 6EWS trim; made in the USA with a 10-year limited warranty

      Best for: Schools, hospitals, and high-traffic entrances

      PDQ 4200R wide stile rim exit device
      Value Wide Stile

      4200 Series

      A cost-conscious rim and surface vertical rod device for standard commercial doors.

      • UL 305 panic listed; fire listed up to 90 minutes on doors up to 3'0" x 7'0"
      • Needs a 4-1/4" stile; 5-year limited warranty

      Best for: Budget-driven projects, tenant fit-outs, and back-of-house doors

      PDQ 9300 removable mullion for double doors
      Double Doors

      9300 Removable Mullion

      Gives each leaf of a pair its own rim device, then comes out with a key when you need the full opening.

      • Works with the 6300R and 6400R
      • 3-hour fire label on pairs up to 8' x 8' with the fire-rated 6300RF or 6400RF
      • 8' or 10' lengths, field cut to fit; wire routing available

      Best for: Pairs of doors that need rim devices on both leaves

      PDQ 6EWS wireless exit device trim
      Outside Trim

      Exit Device Trim

      Levers, pulls, thumb latches, and cylinder-only trim set what someone outside the door can do.

      Best for: Any exit device door that needs access from outside

      Compare PDQ Exit Devices

      Model Series / StileDevice TypeGradeFire RatedElectrified OptionsWarranty
      6300R 6300 / wide, 3-1/2" minRimGrade 1Up to 3 hrMLR, RX, AL, LBM, DE; 6EWS10 yr
      6300V 6300 / wide, 3-1/2" minSurface vertical rodGrade 1Up to 3 hrMLR, RX, AL, LBM, DE; 6EWS10 yr
      6300C 6300 / wide, 3-1/2" minConcealed vertical rodGrade 1Up to 3 hrMLR, RX, AL, LBM, DE10 yr
      6300M 6300 / wide, 5" minMortiseNot graded90 minMLR, RX, AL, LBM, DE10 yr
      6300D 6300 / wide, 3" minDummy (no latch)Not gradedNot ratedRX10 yr
      6400R 6400 / narrow, 3-1/8" minRimGrade 1Up to 3 hrMLR, RX, AL, LBM, DE10 yr
      6400V 6400 / narrow, 3-1/8" minSurface vertical rodGrade 1Up to 3 hrMLR, RX, AL, LBM, DE*10 yr
      6400C 6400 / narrow, 3-1/8" minConcealed vertical rodGrade 1Up to 3 hrMLR, RX, AL, LBM, DE10 yr
      4200R 4200 / wide, 4-1/4" minRimNot graded90 min, 3'0" x 7'0" maxNot offered5 yr
      4200V 4200 / wide, 4-1/4" minSurface vertical rodNot graded90 min, 3'0" x 7'0" maxNot offered5 yr
      9300 For 6300R / 6400R pairsRemovable mullionNot graded3 hr with 6300RF / 6400RFWire routing1 yr

      Every 6300, 6400, and 4200 device except the 6300D is UL 305 listed for panic use, and all comply with ADA and ICC/ANSI A117.1. Fire-listed devices cannot be mechanically dogged. The 6300 and 6400 Series are manufactured in the USA and meet Buy American Act requirements.

      Key: MLR = motorized latch retraction · RX = request to exit switch · AL = alarmed exit · LBM = latch bolt monitor · DE = delayed egress · *6400V delayed egress needs a 3-1/2" stile. 6W99 wired electrified trim is also available. 6EWS = wireless trim, 6300R and 6300V only.

      Ready to spec or order?Find A Sales Rep

      Need Certification Details?

      See every UL, ANSI/BHMA, and ADA listing for PDQ exit devices and the rest of our hardware in one filterable matrix.

      PDQ 6300R Grade 1 rim exit device

      How to Choose an Exit Device

      PDQ 6300R wide stile and 6400R narrow stile rim exit devices

      Step 1

      Match the series to the door's stile

      The stile is the vertical edge of the door where the device mounts and latches, so measure it first. Hollow metal and wood doors usually have wide stiles, which fit the 6300 Series (3-1/2" minimum) or the 4200 Series (4-1/4" minimum). Aluminum storefront and glass doors usually have narrow stiles, which need the 6400 Series (3-1/8" minimum, or 2-1/8" on aluminum frames with the blade stop strike).

      Between the two wide stile lines, the 6300 offers more device types, larger fire-rated doors, and electrified options. The 4200 keeps the cost down on standard 3' doors.

      Person pressing the push pad of a PDQ 6300R rim exit device in 622 black finish to open a gray hollow metal door with a narrow vision lite

       

      Step 2

      Pick the device type for the opening

      A rim exit device latches into a strike on the frame. It is the simplest choice for a single door, and it works on a pair when each leaf latches into a removable mullion at the center. A surface vertical rod exit device runs rods up the face of the door to latch at the head and floor, so a pair can close with no center post. A concealed vertical rod exit device does the same job with the rods hidden inside the door, for a cleaner look at a higher cost. Both vertical rod styles also come less bottom rod where floor latching isn't practical.

      A mortise exit device works with a mortise lock body in the door edge and needs a 5" stile. It suits doors already prepped for a mortise lock. Where a door needs a matching bar but no latch, such as an inner vestibule door, the 6300D dummy keeps the look consistent.

      PDQ 6300 exit device being tested in PDQ's in-house lab

      Step 3

      Check the fire rating and the grade

      Panic hardware is listed to UL 305 for fast exit. Fire exit hardware is also listed to UL 10C, so it can go on a labeled fire door and keep it latched in a fire. If a panic bar door sits in a fire-rated opening, it needs fire exit hardware, and it gives up mechanical dogging because a fire door has to latch every time it closes. PDQ fire listings run from 90 minutes (6300M and 4200) to 3 hours (6300 and 6400 rim and vertical rod).

      Grade comes from ANSI/BHMA A156.3, which tests exit devices for cycles, strength, and security. Grade 1 is the top level and the usual spec for schools, hospitals, and other high-traffic doors. Every 6300 and 6400 rim and vertical rod device is certified Grade 1.

      Where PDQ Exit Devices Fit

      University campus building

      Education

      School doors take heavy traffic at bell times and plenty of abuse. Use the 6300V on main entrance pairs, or 6300R devices with a 9300 mullion where a center post works. For outside access by card or phone, add 6EWS wireless trim to the 6300R or 6300V.

      Hospitals, schools, and other high-traffic buildings that use Grade 1 exit devices

      Healthcare

      Corridor and stair doors in hospitals are often fire rated, so they need fire exit hardware that latches every time. The 6300 and 6400 come in 626 and 630 with an optional antimicrobial coating for high-touch doors. Delayed egress is available where your code official allows it.

      Carhartt corporate office building

      Retail and Commercial

      Use the 6400 on aluminum storefront entrances, and the 6400C where the owner wants no visible rods. Alarmed exit options help on back doors that shouldn't open without notice, and the 4200 keeps cost down on standard back-of-house doors.

      Exit Device and Panic Bar FAQs

      What is a panic bar?

      A panic bar is a bar across the inside of a door that unlatches the door when you push it, so anyone can get out with one motion. It is also called a crash bar or commercial door push bar, and in the industry it is called an exit device or panic hardware. Because it needs no key, knob, or twist, it lets people leave quickly in a crowd or an emergency.

      When are panic bars required?

      Building and life safety codes require panic hardware on latching doors that serve assembly and educational spaces above a set occupant load, and on high-hazard spaces and some electrical and equipment rooms. The exact thresholds depend on which code and edition your jurisdiction has adopted, so confirm with your local code official. Our guide Do All Doors Require Panic Hardware? walks through the common cases.

      What is the difference between rim, surface vertical rod and concealed vertical rod exit devices?

      They differ in where the door latches. A rim device latches into a strike on the frame, so it fits single doors or pairs with a mullion, like the 6300R or 6400R. Surface vertical rod devices like the 6300V latch at the head and floor with rods on the face of the door, so a pair can close with no center post. Concealed vertical rod devices like the 6300C work the same way with the rods hidden inside the door, which looks cleaner and costs more.

      What is the difference between panic hardware and fire exit hardware?

      Panic hardware is listed to UL 305 for fast, easy exit. Fire exit hardware carries that listing plus UL 10C, which approves it for labeled fire doors. A fire-rated door must close and latch every time, so fire exit hardware can't be mechanically dogged open. Most PDQ rim and vertical rod devices are available both ways, with fire listings up to 3 hours.

      What is the difference between Grade 1 and Grade 2 panic bars?

      ANSI/BHMA A156.3 grades exit devices on cycle life, strength, and security, and Grade 1 is the highest. Grade 1 is the usual spec for schools, hospitals, and other high-traffic doors, while Grade 2 can suit lighter-use doors. Every PDQ 6300 and 6400 rim and vertical rod device is certified Grade 1. See Grade 1 vs. Grade 2 panic bars.

      Can an exit device be electrified for access control?

      Yes. PDQ exit devices can be ordered with motorized latch retraction, request-to-exit switches, latch bolt monitoring, alarmed exit, and delayed egress. On the outside, 6W99 electrified trim locks and unlocks the lever from a wired system, and 6EWS wireless trim adds card, phone, and PIN access to the 6300R and 6300V. See electrified hardware for strikes, power supplies, and power transfers.

      Exit Device Guides

      School hallway with a double door exit at the end
      Guide

      Do All Doors Require Panic Hardware? What You Need to Know About Safety and Compliance

      Construction worker with a commercial building in the background
      Guide

      How to Specify Commercial Exit Devices: 8 Criteria That Matter in 2026

      Delayed egress exit device with a school hallway in the background
      Guide

      Safely Ensure Security With Delayed Egress Exit Devices

      Spec Is Right guide to specifying PDQ 6300 and 6400 Series exit devices
      Guide

      Spec Is Right: How to Specify PDQ's 6300 & 6400 Series Exit Devices

      Complete the Opening

      An exit device is one part of the door. Pair it with PDQ closers and electrified hardware for a complete, code-ready opening. Or browse the full PDQ product catalog.

      PDQ 7100 Series Grade 1 door closer

      Door Closers

      Grade 1 closers from light to extra heavy duty, UL listed for 3-hour fire doors.

      PDQ 6EWS electrified exit device trim

      Electrified Hardware

      Electric strikes, power supplies, power transfers, and switches for access-controlled openings.

      Need Help Choosing an Exit Device?

      Tell us about your openings and a PDQ rep will help you match devices to your doors, check stile widths and fire ratings, and get submittals and pricing.