2012, Medicine
Infections of cardiac implantable electronic devices (CIED) can cause significant morbidity, mortality, and financial burden. Although staphylococcal organisms account for most infections of these cardiac devices, approximately 20% of all CIED-related infections are caused by non-Staphylococcus species. Herein we describe and compare the demographics, clinical presentation, and outcomes of Staphylococcus aureus and non-staphylococcal infections of CIED. We performed a retrospective, multicenter, observational study of patients from 4 academic hospitals in Houston between 2002 and 2009. All 80 identified non-staphylococcal CIED-related infections were matched, at a 1:1 ratio, to S. aureus infections. Although the demographics and general comorbidities in the 2 study groups were relatively similar, the S. aureus group had a higher proportion of patients with coronary artery disease, diabetes mellitus, and end-stage renal disease. Additionally, 81% of S. aureus compared with only 48.5% of the non-staphylococcal CIED-related infections were health care-associated (p G 0.001). Furthermore, when compared to non-staphylococcal infections, the S. aureus group had more indwelling intravascular foreign material (p G 0.001), more rapid clinical progression (p G 0.001), and overall worse clinical presentation (p G 0.001). However, after stratifying by clinical presentation, the mortality rates in the 2 groups were similar (p = 0.45). Since approximately one-fifth of all CIED-related infections are caused by non-staphylococcal organisms, and untimely antibiotic treatment can result in serious complications, it may be prudent to broaden empiric antimicrobial therapy to cover both Gram-positive and-negative bacteria, until the causative organism is identified.
Journal of Cardiovascular Electrophysiology, 2011
Microbiologic Characteristics and In Vitro Susceptibility to Antimicrobials. Introduction: The incidence of cardiovascular implantable electronic device (CIED) infection is steadily increasing. However, no consensus has been reached with respect to the type and duration of antimicrobial therapy in this specific population of patients. The role played by new anti-Staphylococcus agents has not been defined. The aims of this study were to describe the microbiological characteristics of a large population of patients with CIED infections and to test the in vitro susceptibility of the various strains to different antimicrobials. Methods: Two hundred eighty-six patients with CIED infection were included. The minimal inhibitory concentrations of 9 antimicrobials, including linezolid, tigecycline, and daptomycin were measured against all strains of staphylococci isolated. Results: Microbiologic confirmation was obtained in 252 (88%) patients, the vast majority were from Staphylococcus species (86%), 90% of these were coagulase negative strains and 10% were Staphylococcus aureus; 30.5% were methicillin-resistant. All strains were susceptible to vancomycin, nearly 15% of coagulase negative strains were nonsusceptible to teicoplanin, and nearly 100% of the strains were susceptible to the 3 new antimicrobials. Conclusions: In this large contemporary study, we show that Staphylococcus is by far the most common cause of CIED infections, with the majority due to coagulase negative strains. Methicillin-resistance is common in this population. Currently, we would recommend vancomycin as first-line empirical therapy. However, given that not all patients tolerate vancomycin, we believe that newer antimicrobial therapies should now be tested in clinical trials to establish their clinical effectiveness in treating patients with device infections.
Objective: The objective of the study was to determine the microbiological spectrum of cardiac implantable electronic device (CIED) infections.
Journal of the American Dental Association, 2011
Background. The purpose of this statement is to update the recommendations by the American Heart Association (AHA) for cardiovascular implantable electronic device (CIED) infections and their management, which were last published in 2003. Methods and Results. The AHA commissioned this scientific statement to educate clinicians about CIED infections, provide explicit recommendations for the care of patients with suspected or established CIED infections and highlight areas of needed research. The recommendations in this statement reflect analyses of relevant literature, to include recent advances in our understanding of the epidemiology, risk factors, microbiology, management and prevention of CIED infections. Conclusion. There are no scientific data to support the use of antimicrobial prophylaxis for dental or other invasive procedures. Clinical Implications. The concerns about life-threatening drug reactions, the development of resistant strains of bacterial pathogens, medicolegal issues and cost to the health care system are, thus, avoided.
The American Journal of Cardiology, 2013
for the Mayo Cardiovascular Infections Study Group Infection reduces survival in cardiovascular implantable electronic device (CIED) recipients. However, the clinical predictors of short-and long-term mortality in patients with CIED infection are not well understood. We retrospectively reviewed all patients with CIED infection who were admitted to Mayo Clinic from January 1991 to December 2008. Survival data were obtained from the medical records and the United Sates Social Security Index. The purported risk factors for short-term (30-day) and long-term (>30-day) mortality were analyzed using univariate and multivariate models. Overall, 415 cases of CIED infection were identified during the study period. The mean follow-up duration for the 243 patients who were alive at the last follow-up visit was 6.9 years. In a multivariate model, heart failure (odds ratio 9.31, 95% confidence interval 2.08 to 41.67), corticosteroid therapy (odds ratio 4.04, 95% confidence interval 1.40 to 11.60), and presentation with CIED-related infective endocarditis (odds ratio 5.60, 95% confidence interval 2.25 to 13.92) were associated with increased short-term mortality. The factors associated with long-term mortality in the multivariate model included patient age (hazard ratio 1.20, 95% confidence interval 1.06 to 1.36), heart failure (hazard ratio 2.01, 95% confidence interval 1.42 to 2.86), metastatic malignancy (hazard ratio 5.99, 95% confidence interval 1.67 to 21.53), corticosteroid therapy (hazard ratio 1.97, 95% confidence interval 1.22 to 3.18), renal failure (hazard ratio 1.94, 95% confidence interval 1.37 to 2.74), and CIED-related infective endocarditis (hazard ratio 1.68, 95% confidence interval 1.17 to 2.41). In conclusion, these data suggest that the development of CIED-related infective endocarditis and the presence of co-morbid conditions are associated with increased short-and long-term mortality in patients with CIED infection.
Journal of Clinical Medicine
Background: Infections following cardiac implantable electronic device (CIED) implantation can require surgical device removal and often results in significant cost, morbidity, and potentially mortality. We aimed to systemically review the literature and identify risk factors associated with mortality following CIED infection. Methods: Electronic searches (up to June 2021) were performed on PubMed and Scopus. Twelve studies (10 retrospective, 2 prospective cohort studies) were included for analysis. Meta-analysis was conducted with the restricted maximum likelihood method, with mortality as the outcome. The overall mortality was 13.7% (438/1398) following CIED infection. Results: On meta-analysis, the male sex (OR 0.77, 95%CI 0.57–1.01, I2 = 2.2%) appeared to have lower odds for mortality, while diabetes mellitus appeared to be associated with higher mortality (OR 1.47, 95%CI 0.67–3.26, I2 = 81.4%), although these trends did not reach statistical significance. Staphylococcus aureus ...
Journal of Hospital Infection, 2020
Background: Clinical outcomes of patients undergoing a cardiac implantable electronic device (CIED) implantation following a recent non-device related infection are unknown. Aim: To evaluate the clinical outcomes of patients with recent infection before CIED implantation. Methods: Consecutive patients (N ¼ 1237) were classified as patients with recent infection (N ¼ 72) and without recent infection (N ¼ 1165). A recent infection was established by reviewing medical records, including symptoms and clinical manifestations, diagnosis of systemic inflammatory response syndrome, and quick Sequential Organ Failure Assessment (qSOFA) score. Multiple stepwise logistic regression analysis was used to identify independent predictors of in-hospital all-cause mortality. Findings: During nearly three years of follow-up, 17 patients had CIED infection (1.4%), and the incidence of CIED infection did not significantly differ between patients with and without recent infection according to symptoms and clinical manifestations (2.8% vs 1.3%, respectively; not significant). However, patients with recent infection had a significantly higher in-hospital mortality rate compared to those without recent infection (22.2% vs 0.9%, respectively; P < 0.05). In multivariate analysis, predictors of in-hospital mortality were recent infection before CIED implantation (odds ratio: 20.3; 95% confidence interval: 8.4e49.3; P < 0.001) and end-stage renal disease (4.3; 1.4e12.8; P ¼ 0.009). Conclusion: A CIED implantation is feasible in patients with recent infection if the patient is afebrile and has received an adequate duration of antibiotic therapy. Participants in shared decision-making before implant should be advised that recent infection increases in-hospital mortality risk, especially in patients with a qSOFA score of !2.
Hospital chronicles, 2014
New England Journal of Medicine, 2019
BACKGROUND Infections after placement of cardiac implantable electronic devices (CIEDs) are associated with substantial morbidity and mortality. There is limited evidence on prophylactic strategies, other than the use of preoperative antibiotics, to prevent such infections. METHODS We conducted a randomized, controlled clinical trial to assess the safety and efficacy of an absorbable, antibiotic-eluting envelope in reducing the incidence of infection associated with CIED implantations. Patients who were undergoing a CIED pocket revision, generator replacement, or system upgrade or an initial implantation of a cardiac resynchronization therapy defibrillator were randomly assigned, in a 1:1 ratio, to receive the envelope or not. Standard-of-care strategies to prevent infection were used in all patients. The primary end point was infection resulting in system extraction or revision, long-term antibiotic therapy with infection recurrence, or death, within 12 months after the CIED implantation procedure. The secondary end point for safety was procedure-related or system-related complications within 12 months. RESULTS A total of 6983 patients underwent randomization: 3495 to the envelope group and 3488 to the control group. The primary end point occurred in 25 patients in the envelope group and 42 patients in the control group (12-month Kaplan-Meier estimated event rate, 0.7% and 1.2%, respectively; hazard ratio, 0.60; 95% confidence interval [CI], 0.36 to 0.98; P = 0.04). The safety end point occurred in 201 patients in the envelope group and 236 patients in the control group (12-month Kaplan-Meier estimated event rate, 6.0% and 6.9%, respectively; hazard ratio, 0.87; 95% CI, 0.72 to 1.06; P<0.001 for noninferiority). The mean (±SD) duration of follow-up was 20.7±8.5 months. Major CIED-related infections through the entire follow-up period occurred in 32 patients in the envelope group and 51 patients in the control group (hazard ratio, 0.63; 95% CI, 0.40 to 0.98). CONCLUSIONS Adjunctive use of an antibacterial envelope resulted in a significantly lower incidence of major CIED infections than standard-of-care infection-prevention strategies alone, without a higher incidence of complications. (Funded by Medtronic; WRAP-IT ClinicalTrials.gov number, NCT02277990.
International Journal of Cardiology, 2013
Background: The prevalence of cardiac device-related infections (CDIs) has mirrored the unprecedented increase in device usage. CDIs are currently one of the leading indications for extraction. Despite this, there is limited data regarding the clinical trends, management and outcomes associated with this complication. Methods: A review of a prospective registry of all patients undergoing device extraction between January 1, 2004, and June 15, 2009, at a single high-volume tertiary referral center was performed. Results: A total of 506 consecutive patients were identified. From these, 350 patients were identified as having a CDI (205 ICD, 145 PPM). The mean age was 69.9 ± 13.7. Although most patients presented clinically with signs of a pocket infection (PI) (42%), the most common final diagnosis was cardiac device infective endocarditis (CDIE) (57%). The two most common pathogens were methicillin-resistant Staphylococcus aureus (27%) and methicillin-resistant Staphylococcus epidermidis (23%); they accounted for 69% of all deaths. Cultures taken from pocket tissue as opposed to exudates displayed higher concordance with lead-tip cultures (56% and 31% respectively). The mean time from explantation to device reimplantation for PIs, bacteremia and CDIE was 6.7 ± 4.7, 10.25 ± 4.7 and 11.39 ± 16.6 days respectively. Conclusion: CDIs are a serious complication associated with device usage. Diagnosis and management protocols for CDIs should feature transesophageal echocardiography; complete hardware extraction; broad-spectrum antibiotics that cover methicillin-resistant Staphylococci and cultures derived from lead-tips and preferably pocket tissue. Immediate device reimplantation is possible in noninfectious cases; several factors should be considered regarding reimplantation in cases involving CDIs.
Open Access Macedonian Journal of Medical Sciences, 2021
Background: It has been demonstrated that the use of cardiac implanted electronic devices (CIED) improve mortality and survivability in a variety of patient populations. Nevertheless, CIED related infection is a serious complication characterized by a high rate of mortality and morbidity. Objectives: To evaluate the prevalence of CIED related infections, risk factors, clinical and demographic characteristics, causative organisms, and the management and outcome of patients presented in the Critical Care Department, Cairo University. Methods: A retrospective analysis was conducted in 1871 individuals who had been implanted with a cardiac device with a total number of devices of 1968 and 2270 procedures performed from January 2007 to December 2017. Results: 59 infectious episodes were identified with an estimated incidence of 2.99% of inserted devices and 2.6% of total procedures. The infection rate was considerably higher in patients with multiple procedures than those who had a sin...
Medicine, 2020
Background: Over the past decade, rates of cardiac implantable electronic device (CIED) related infections have increased and been associated with increased morbidity, mortality and financial burden on healthcare systems. Methods: To examine the effect of an antibacterial envelope in reducing major CIED related infections, we performed a systematic review and meta-analysis by searching PubMed/MEDLINE, CENTRAL, Google scholar and Clinicaltrials.gov for studies that examined the effect of an antibiotic envelope in reducing major related CIED infections, comprising of device-related endocarditis, systemic infection requiring systemic antibiotics and or device extraction, compared to control up till February 15th, 2020. A randomeffects meta-analysis was conducted by calculating risk ratios (RR) and respective 95% confidence intervals (CI). Results: We include 6 studies that comprise of 11,897 patients, of which 5844 received an antibiotic envelope and 6053 did not. Compared with control, utilization of an antibiotic envelope at the time of procedure was associated with a significant 74% relative risk reduction in major CIED related infections among patients at high risk for infection (RR: 0.26 [95% CI, 0.08-0.85]; P = .03), while no significant reduction was observed among patients enrolled from studies with any risk for infection (RR: 0.53 [95% CI, 0.06-4.52]; P = .56). Additionally, no reduction in mortality among patients that received an envelope compared to control was observed (RR: 1.15 [95% CI, 0.53-2.50]; P = .72). Conclusion: The utilization of an antibiotic envelope at the time of device implantation or upgrade reduces major CIED infections, especially if used in patients perceived to be at higher risk for infection. Abbreviations: CIED = cardiac implantable electronic device, CRT-D = cardiac resynchronization therapy-defibrillator, CRT-P = cardiac resynchronization therapy-Pacemaker, ICD = implantable cardioverter defibrillator, PPM = permanent pacemaker.
Pacing and Clinical Electrophysiology, 2014
Background: Device infection is associated with increased mortality in patients receiving cardiovascular implantable electronic device (CIED) therapy. However, long-term mortality associated with CIED infections has not been systematically analyzed in larger studies. This study sought to determine the long-term mortality associated with CIED infection in a large cohort of Medicare beneficiaries. Methods: We used a retrospective study design to analyze 3-year mortality in 200,219 Medicare fee-forservice patients admitted for CIED generator implantation, replacement, or revision between January 1, 2007 and December 31, 2007. Multivariate analysis adjusting for age, sex, race, and 28 comorbidities was performed to determine the relative risk (RR) of death in the 12 quarters following CIED infection. Results: Patients with CIED infection, compared to device recipients without infection, had increased mortality that persisted for at least 3 years after the admission quarter for all device types: pacemakers (PMs: 53.8% vs 33%; P < 0.001), implantable cardioverter defibrillator (ICD: 47.7% vs 31.6%; P < 0.001), and cardiac resynchronization therapy-defibrillator (CRT-D: 50.8% vs 36.5%; P < 0.001). After adjusting for patient demographics and comorbidities, significantly increased RR of death following CIED infection persisted for at least 3 years following PM infection, and for at least 2 years with single-and dual-chamber ICD infection. Conclusions: CIED recipients who develop device infection have increased, device-dependent, longterm mortality even after successful treatment of infection. The etiology of this persistent increased risk of death associated with CIED infection is unknown and merits further investigation.
Open Forum Infectious Diseases, 2021
Background The Prevention of Arrhythmia Device Infection Trial (PADIT) investigated whether intensification of perioperative prophylaxis could prevent cardiac implantable electronic device (CIED) infections. Compared with a single dose of cefazolin, the perioperative administration of cefazolin, vancomycin, bacitracin, and cephalexin did not significantly decrease the risk of infection. Our objective was to compare the microbiology of infections between study arms in PADIT. Methods This was a post hoc analysis. Differences between study arms in the microbiology of infections were assessed at the level of individual patients and at the level of microorganisms using the Fisher exact test. Results Overall, 209 microorganisms were reported from 177 patients. The most common microorganisms were coagulase-negative staphylococci (CoNS; 82/209 [39.2%]) and S. aureus (75/209 [35.9%]). There was a significantly lower proportion of CoNS in the incremental arm compared with the standard arm (30...
European Heart Journal, 2022
Cardiac implantable electronic device (CIED) infection is a severe complication to modern management of cardiac arrhythmias. The CIED type and the type of surgery are recognized as risk factors for CIED infections, but knowledge of patientrelated risk factors is scarce. This study aimed to identify lifelong patient-related risk factors for CIED infections. Methods and results Consecutive Danish patients undergoing a CIED implantation or reoperation between January 1996 and April 2018 were included. The cohort consisted of 84 429 patients undergoing 108 494 CIED surgeries with a combined follow-up of 458 257 CIED-years. A total of 1556 CIED explantations were classified as either pocket (n = 1022) or systemic CIED infection (n = 534). Data were cross-linked with records from the Danish National Patient Registry and the Danish National Prescription Registry. Using multiple-record and multiple-event per subject proportional hazard analysis, specific patient-related risk factors were identified but with several variations amongst the subtypes of CIED infection. CIED reoperations were associated with the highest risk of pocket CIED infection but also CIED type, young age, and prior valvular surgery [hazard ratio (HR): 1.62, 95% confidence interval (CI): 1.29-2.04]. Severe renal insufficiency/dialysis (HR: 2.40, 95% CI: 1.65-3.49), dermatitis (HR: 2.80, 95% CI: 1.92-4.05), and prior valvular surgery (HR: 2.09, 95% CI: 1.59-2.75) were associated with the highest risk of systemic CIED infections. Congestive heart failure, ischaemic heart disease, malignancy, chronic obstructive pulmonary disease, and temporary pacing were not significant at multivariate analysis. Conclusion Specific comorbidities and surgical procedures were associated with a higher risk of CIED infections but with variations amongst pocket and systemic CIED infection. Pocket CIED infections were associated with CIED reoperations, young age and more complex type of CIED, whereas systemic CIED infections were associated with risk factors predisposing to bacteraemia.
Indian Journal of Microbiology Research, 2023
Cardiovascular implantable electronic devices (CIED) improve quality of life of patients with cardiac arrhythmias and also improves chances of survival. CIEDs, however it may cause complications. To avoid these complications surgical prophylaxis in CIED insertion is required to avoid infection. Due to the rise in antimicrobial resistance the use of antimicrobial agents should be rational and under control. To prevent resistance of antibiotics their use and duration of therapy should be monitored. The high-end and restricted antibiotics should be used only if organisms grow in cultures or if suggested by infectious disease specialists. This review focuses on empirical antibiotics used as prophylaxis. The purpose of this document is to outline the antimicrobial options which can be used as an empirical prophylactic agent in CIED infections. Keywords: Staphylococcus species, Blood culture, Pocket infection
Heart Rhythm, 2010
BACKGROUND Indications for cardiac implantable electronic devices (CIEDs) are increasing. Although CIED infections occur infrequently, the impact of this outcome is expected to be substantial. OBJECTIVE The purpose of this study was to the evaluate the outcome of patients undergoing removal of infected CIEDs. METHODS A retrospective study was conducted of all patients with proven or suspected infected CIEDs who were referred to the Cleveland Clinic for system removal from January 2002 through March 2007. RESULTS A total of 412 patients (age 68 Ϯ 15 years) were included in the study. The majority of patients (241 [59%]) presented with localized infection involving the device pocket. The remaining 171 patients (41%) presented with endovascular infection but no evidence of inflammation of the device pocket. Of the total 414 pathogens isolated, 366 (88%) were aerobic grampositive organisms, of which 90% were Staphylococcus species, and almost half of these were methicillin resistant. In-hospital mortality was 4.6% (19 patients). Only 2 deaths were extraction related. One-year mortality was 17%. Among the total cohort, 8 (1.9%) patients had relapsing infection within the first year. Among patients who had device replacement during the same hospitalization, 6 (2.6%) had relapsing infections within 1 year of reimplantation; 5 of these patients had systemic symptoms and were bacteremic upon initial presentation. CONCLUSION CIED infections are most often caused by Staphylococcus species, half of which are methicillin resistant. Percutaneous lead and device removal along with antibiotic therapy are effective as primary interventions. The overall relapse rate is 1.9%, and the relapse rate among patients who had reimplantation during the same hospitalization is 2.6%.
Pacing and Clinical Electrophysiology, 2012
Background: The use of cardiovascular implantable electronic devices (CIEDs) is increasing. Staphylococcus aureus bacteremia (SAB) poses a risk for hematogenous seeding of the device. Our aim is to identify risk factors associated with secondary CIED infection, due to hematogenous seeding, during SAB from an unrelated primary focus. Methods: All patients with SAB and CIED were screened. Patients with SAB due to a primary source unrelated to the CIED were included. Patients were classified into cases if CIED infection was documented and controls without CIED infection during a minimum of 12 weeks follow-up. A retrospective review of patients' charts was done. Results: Thirty patients with CIED and SAB from an unrelated focus were identified. CIED infection developed in 11 patients (36.7%). No significant differences were noted between cases and controls in the source, time-to-therapy, and time-to-intervene but infected devices were more likely to be implantable cardioverter-defibrillators (ICD) versus permanent pacemakers (PPMs) (9/11 [81.8%] vs 2/11 [18.2%] respectively, crude odds ratio 12.6, 95% confidence interval 10.8-14.4; P = 0.003). Conclusion: Hematogenous seeding of a CIED during SAB from an unrelated focus is not uncommon. The risk factors for CIED seeding are unknown but ICD devices seem to be at greater risk when compared to PPM. The reasons are not yet clear. Larger studies are needed to better define risk factors and design preventive measures. (PACE 2012;XX:1-5) cardiovascular device, Staphylococcus aureus bacteremia, secondary infection, seeding No funding was required for this project. Address for reprints: Karam M. Obeid, M.D.
Europace, 2012
The purpose of our survey is to analyse the clinical approach used to prevent and treat cardiovascular implantable electronic device (CIED) infections in Europe. The survey involves high-volume implanting centres. According to the survey the incidence of CIED infections shows a slight decrease in most centres and is substantially under 2% in the majority of centres interviewed. However, there are still differences in terms of prophylactic antibiotic therapy: 8.9% of the centres administer oxacillin as preoperative treatment, 4.4% of them do not give any antibiotic therapy, all centres use some kind of skin antisepsis, but only 42.2% use chlorhexidine. In case of local infection, 43.5% of centres perform lead extraction as first approach. In the case of systemic infection or evidence of lead or valvular endocarditis, 95% of centres treat these conditions by extracting the leads, which indicates that the adherence to the lead extraction guidelines is quite good.
Circulation, 2010
Open Forum Infectious Diseases, 2019
Background. Generator pocket infection is the most frequent presentation of cardiovascular implantable electronic device (CIED) infection. We aim to identify predictors of underlying bloodstream infection (BSI) in patients presenting with CIED pocket infection. Methods. We retrospectively reviewed all adults with CIED pocket infection cared for at our institution from January 2005 through January 2016. The CIED pocket infection cases were then subclassified as with or without associated BSI. Variables with P values <.05 at univariate analysis were included in a multivariable model to identify independent predictors of underlying BSI. Results. We screened 429 cases of CIED infection, and 95 met the inclusion criteria. Of these, 68 cases (71.6%) were categorized as non-BSI and 27 (28.4%) as BSI. There were no statistically significant differences in patient comorbid conditions or device characteristics between the 2 groups. In multivariable analysis, the presence of systemic inflammatory response syndrome criteria (tachycardia, tachypnea, fever or hypothermia, and leukocytosis or leukopenia) and hypotension were independent predictors of underlying BSI in patients presenting with CIED pocket infection. Overall, patients in the non-BSI group who did not receive pre-extraction antibiotics had a higher frequency of positive intraoperative pocket/device cultures than those with pre-extraction antibiotic exposure (79.4% vs 58.6%; P = .06). Conclusions. Patients with CIED pocket infection who meet systemic inflammatory response syndrome criteria and/or are hypotensive at admission are more likely to have underlying BSI and should be started on empiric antibiotics after blood cultures are obtained. If these features are absent, it may be reasonable to withhold empiric antibiotics to optimize yield of pocket/device cultures during extraction.