{"id":14481,"date":"2013-12-09T15:04:18","date_gmt":"2013-12-09T20:04:18","guid":{"rendered":"http:\/\/www.ustpower.wpengine.com\/?p=14481"},"modified":"2022-05-04T11:08:28","modified_gmt":"2022-05-04T16:08:28","slug":"diesel","status":"publish","type":"post","link":"https:\/\/ustpower.com\/diesel\/","title":{"rendered":"Quiet Generators. Happy Guests."},"content":{"rendered":"<div class=\"wpb-content-wrapper\" id=\"wpb-content-root\"><p>[vc_row][vc_column][vc_column_text]<img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-14050 size-medium\" src=\"\/wp-content\/uploads\/White_Paper_Deisel_iPad_Final_444_New.jpg\" alt=\"Electronic Voltage Regulation Case Study Cover\" width=\"211\" height=\"300\" \/>A UST WHITE PAPER<\/p>\n<h3>The economic case for adding electronic voltage regulation to backup power systems at hotels, resorts and casinos.<\/h3>\n<p>As the demand for exotic travel experiences grows, resort developers are increasingly building in places where power quality remains a significant challenge \u2013 the Caribbean, Central America, South America, the South Pacific, much of Africa, and parts of Asia. Until very recently, in order to ensure that essential services could be maintained, engineers had to design backup power systems that would start the moment a power anomaly occurred, sever the connection to the local grid and supply power independently, not only during blackouts, but also during more prevalent brownouts, sags and surges.<\/p>\n<p>Within the last decade, an extremely reliable and low maintenance technology, electronic voltage regulators (EVRs), transformers equipped with electronic on-load tap changers, have proven very effective at compensating for variations in incoming voltage.<\/p>\n<p>This paper explores the compelling financial analysis used by more and more hospitality industry decision makers when adding an EVR as the third component of their power conditioning system.[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column]<div class=\"gap\" style=\"line-height: 18px; height: 18px;\"><\/div><a href=\"\/diesel-whitepaper\/\" class=\"btn-shortcode dt-btn-l dt-btn default-btn-color default-btn-hover-color default-btn-bg-color default-btn-bg-hover-color\" target=\"_blank\" id=\"dt-btn-1\" rel=\"noopener\"><span>DOWNLOAD NOW<\/span><\/a><a href=\"\/white-papers\/\" class=\"btn-shortcode dt-btn-l dt-btn default-btn-color default-btn-hover-color default-btn-bg-color default-btn-bg-hover-color\" target=\"_blank\" id=\"dt-btn-2\" rel=\"noopener\"><span>MORE WHITE PAPERS<\/span><\/a>[\/vc_column][\/vc_row]<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<h3>The economic case for adding electronic voltage regulation to backup power systems at hotels, resorts and casinos.<\/h3>\n<p>A UST WHITE PAPER<\/p>\n<p><a href=\"\/diesel-whitepaper\/\"><strong>Download It Now<\/strong><\/a><\/p>\n<p>This paper explores the compelling financial analysis used by more and more hospitality industry decision makers when adding an EVR as the third component of their power conditioning system.<\/p>\n","protected":false},"author":2,"featured_media":21946,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"content-type":"","footnotes":""},"categories":[124,9],"tags":[],"class_list":["post-14481","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-poor-utility-voltage","category-whitepapers","category-124","category-9","description-off"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Adding Electronic Voltage Regulation to Backup Power Systems | Case Study | UST<\/title>\n<meta name=\"description\" content=\"Explore the compelling financial analysis used by the hospitality industry when adding an EVR as the third component of their power conditioning system.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/ustpower.com\/diesel\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Adding Electronic Voltage Regulation to Backup Power Systems | Case Study | UST\" \/>\n<meta property=\"og:description\" content=\"Explore the compelling financial analysis used by the hospitality industry when adding an EVR as the third component of their power conditioning system.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/ustpower.com\/diesel\/\" \/>\n<meta property=\"og:site_name\" content=\"UST\" \/>\n<meta property=\"article:published_time\" content=\"2013-12-09T20:04:18+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2022-05-04T16:08:28+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/ustpower.com\/wp-content\/uploads\/White_Paper_Deisel_iPad_Final_444_New.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"444\" \/>\n\t<meta property=\"og:image:height\" content=\"631\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Ron Ladouceur\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Ron Ladouceur\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/ustpower.com\\\/diesel\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/ustpower.com\\\/diesel\\\/\"},\"author\":{\"name\":\"Ron Ladouceur\",\"@id\":\"https:\\\/\\\/ustpower.com\\\/#\\\/schema\\\/person\\\/61f038250005fa0b3b3e7ab1374f4e7b\"},\"headline\":\"Quiet Generators. Happy Guests.\",\"datePublished\":\"2013-12-09T20:04:18+00:00\",\"dateModified\":\"2022-05-04T16:08:28+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/ustpower.com\\\/diesel\\\/\"},\"wordCount\":230,\"publisher\":{\"@id\":\"https:\\\/\\\/ustpower.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/ustpower.com\\\/diesel\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/ustpower.com\\\/wp-content\\\/uploads\\\/White_Paper_Deisel_iPad_Final_444_New.jpg\",\"articleSection\":[\"Poor Utility Voltage\",\"Whitepapers\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/ustpower.com\\\/diesel\\\/\",\"url\":\"https:\\\/\\\/ustpower.com\\\/diesel\\\/\",\"name\":\"Adding Electronic Voltage Regulation to Backup Power Systems | Case Study | UST\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/ustpower.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/ustpower.com\\\/diesel\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/ustpower.com\\\/diesel\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/ustpower.com\\\/wp-content\\\/uploads\\\/White_Paper_Deisel_iPad_Final_444_New.jpg\",\"datePublished\":\"2013-12-09T20:04:18+00:00\",\"dateModified\":\"2022-05-04T16:08:28+00:00\",\"description\":\"Explore the compelling financial analysis used by the hospitality industry when adding an EVR as the third component of their power conditioning system.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/ustpower.com\\\/diesel\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/ustpower.com\\\/diesel\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/ustpower.com\\\/diesel\\\/#primaryimage\",\"url\":\"https:\\\/\\\/ustpower.com\\\/wp-content\\\/uploads\\\/White_Paper_Deisel_iPad_Final_444_New.jpg\",\"contentUrl\":\"https:\\\/\\\/ustpower.com\\\/wp-content\\\/uploads\\\/White_Paper_Deisel_iPad_Final_444_New.jpg\",\"width\":444,\"height\":631},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/ustpower.com\\\/diesel\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/ustpower.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Quiet Generators. Happy Guests.\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/ustpower.com\\\/#website\",\"url\":\"https:\\\/\\\/ustpower.com\\\/\",\"name\":\"UST\",\"description\":\"Industrial-Grade Automatic Voltage Regulators\",\"publisher\":{\"@id\":\"https:\\\/\\\/ustpower.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/ustpower.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/ustpower.com\\\/#organization\",\"name\":\"Utility Systems Technologies\",\"url\":\"https:\\\/\\\/ustpower.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/ustpower.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/ustpower.com\\\/wp-content\\\/uploads\\\/2015\\\/08\\\/UST-Logo-Full-Color-Center-72-dpi-USTblu.png\",\"contentUrl\":\"https:\\\/\\\/ustpower.com\\\/wp-content\\\/uploads\\\/2015\\\/08\\\/UST-Logo-Full-Color-Center-72-dpi-USTblu.png\",\"width\":147,\"height\":90,\"caption\":\"Utility Systems Technologies\"},\"image\":{\"@id\":\"https:\\\/\\\/ustpower.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/ustpower.com\\\/#\\\/schema\\\/person\\\/61f038250005fa0b3b3e7ab1374f4e7b\",\"name\":\"Ron Ladouceur\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/cc4d54196962e1ae0bd7fd1fdb119e709423199be814a3b645ecad4281ac340d?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/cc4d54196962e1ae0bd7fd1fdb119e709423199be814a3b645ecad4281ac340d?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/cc4d54196962e1ae0bd7fd1fdb119e709423199be814a3b645ecad4281ac340d?s=96&d=mm&r=g\",\"caption\":\"Ron Ladouceur\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Adding Electronic Voltage Regulation to Backup Power Systems | Case Study | UST","description":"Explore the compelling financial analysis used by the hospitality industry when adding an EVR as the third component of their power conditioning system.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/ustpower.com\/diesel\/","og_locale":"en_US","og_type":"article","og_title":"Adding Electronic Voltage Regulation to Backup Power Systems | Case Study | UST","og_description":"Explore the compelling financial analysis used by the hospitality industry when adding an EVR as the third component of their power conditioning system.","og_url":"https:\/\/ustpower.com\/diesel\/","og_site_name":"UST","article_published_time":"2013-12-09T20:04:18+00:00","article_modified_time":"2022-05-04T16:08:28+00:00","og_image":[{"width":444,"height":631,"url":"https:\/\/ustpower.com\/wp-content\/uploads\/White_Paper_Deisel_iPad_Final_444_New.jpg","type":"image\/jpeg"}],"author":"Ron Ladouceur","twitter_misc":{"Written by":"Ron Ladouceur","Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/ustpower.com\/diesel\/#article","isPartOf":{"@id":"https:\/\/ustpower.com\/diesel\/"},"author":{"name":"Ron Ladouceur","@id":"https:\/\/ustpower.com\/#\/schema\/person\/61f038250005fa0b3b3e7ab1374f4e7b"},"headline":"Quiet Generators. Happy Guests.","datePublished":"2013-12-09T20:04:18+00:00","dateModified":"2022-05-04T16:08:28+00:00","mainEntityOfPage":{"@id":"https:\/\/ustpower.com\/diesel\/"},"wordCount":230,"publisher":{"@id":"https:\/\/ustpower.com\/#organization"},"image":{"@id":"https:\/\/ustpower.com\/diesel\/#primaryimage"},"thumbnailUrl":"https:\/\/ustpower.com\/wp-content\/uploads\/White_Paper_Deisel_iPad_Final_444_New.jpg","articleSection":["Poor Utility Voltage","Whitepapers"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/ustpower.com\/diesel\/","url":"https:\/\/ustpower.com\/diesel\/","name":"Adding Electronic Voltage Regulation to Backup Power Systems | Case Study | UST","isPartOf":{"@id":"https:\/\/ustpower.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/ustpower.com\/diesel\/#primaryimage"},"image":{"@id":"https:\/\/ustpower.com\/diesel\/#primaryimage"},"thumbnailUrl":"https:\/\/ustpower.com\/wp-content\/uploads\/White_Paper_Deisel_iPad_Final_444_New.jpg","datePublished":"2013-12-09T20:04:18+00:00","dateModified":"2022-05-04T16:08:28+00:00","description":"Explore the compelling financial analysis used by the hospitality industry when adding an EVR as the third component of their power conditioning system.","breadcrumb":{"@id":"https:\/\/ustpower.com\/diesel\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/ustpower.com\/diesel\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/ustpower.com\/diesel\/#primaryimage","url":"https:\/\/ustpower.com\/wp-content\/uploads\/White_Paper_Deisel_iPad_Final_444_New.jpg","contentUrl":"https:\/\/ustpower.com\/wp-content\/uploads\/White_Paper_Deisel_iPad_Final_444_New.jpg","width":444,"height":631},{"@type":"BreadcrumbList","@id":"https:\/\/ustpower.com\/diesel\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/ustpower.com\/"},{"@type":"ListItem","position":2,"name":"Quiet Generators. Happy Guests."}]},{"@type":"WebSite","@id":"https:\/\/ustpower.com\/#website","url":"https:\/\/ustpower.com\/","name":"UST","description":"Industrial-Grade Automatic Voltage Regulators","publisher":{"@id":"https:\/\/ustpower.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/ustpower.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/ustpower.com\/#organization","name":"Utility Systems Technologies","url":"https:\/\/ustpower.com\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/ustpower.com\/#\/schema\/logo\/image\/","url":"https:\/\/ustpower.com\/wp-content\/uploads\/2015\/08\/UST-Logo-Full-Color-Center-72-dpi-USTblu.png","contentUrl":"https:\/\/ustpower.com\/wp-content\/uploads\/2015\/08\/UST-Logo-Full-Color-Center-72-dpi-USTblu.png","width":147,"height":90,"caption":"Utility Systems Technologies"},"image":{"@id":"https:\/\/ustpower.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/ustpower.com\/#\/schema\/person\/61f038250005fa0b3b3e7ab1374f4e7b","name":"Ron Ladouceur","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/cc4d54196962e1ae0bd7fd1fdb119e709423199be814a3b645ecad4281ac340d?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/cc4d54196962e1ae0bd7fd1fdb119e709423199be814a3b645ecad4281ac340d?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/cc4d54196962e1ae0bd7fd1fdb119e709423199be814a3b645ecad4281ac340d?s=96&d=mm&r=g","caption":"Ron Ladouceur"}}]}},"_links":{"self":[{"href":"https:\/\/ustpower.com\/wp-json\/wp\/v2\/posts\/14481","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ustpower.com\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/ustpower.com\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/ustpower.com\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/ustpower.com\/wp-json\/wp\/v2\/comments?post=14481"}],"version-history":[{"count":0,"href":"https:\/\/ustpower.com\/wp-json\/wp\/v2\/posts\/14481\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/ustpower.com\/wp-json\/wp\/v2\/media\/21946"}],"wp:attachment":[{"href":"https:\/\/ustpower.com\/wp-json\/wp\/v2\/media?parent=14481"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/ustpower.com\/wp-json\/wp\/v2\/categories?post=14481"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/ustpower.com\/wp-json\/wp\/v2\/tags?post=14481"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}