Papers by Mario Garavaglia
Ablefaria (o Criptoftalmos): Ausencia congénita de los párpados, la hendidura palpebral no se abr... more Ablefaria (o Criptoftalmos): Ausencia congénita de los párpados, la hendidura palpebral no se abre. Generalmente es bilateral.
Journal of Modern Optics, Jun 1, 2003
Abstract The theoretical and experimental results of the Moiré effect observed by superposing two... more Abstract The theoretical and experimental results of the Moiré effect observed by superposing two grids containing fractal Cantor structures are presented in this paper. It is also analysed the equivalence between the information obtained by the Fraunhofer ...
IEEE Journal of Quantum Electronics, Oct 1, 1977

IEEE Journal of Quantum Electronics, Nov 1, 1970
About Unidentified Ionized Xe Laser Lines thode 'Window Fig 3 LEp ultrafast TVHRO6 photodiode wit... more About Unidentified Ionized Xe Laser Lines thode 'Window Fig 3 LEp ultrafast TVHRO6 photodiode with main chara&eristics: rise timei o ps; maximum (linear) c u r r e n t 3 amperes; output ~mpedance-50 ohms; s20 photocathode, quantum efficiency a t 4300 A-0.1 electron/photon (30 mA/ w); photocathode diameter-6 mm; anode-cathode distance-0.8 mm. butions from the oscilloscope, the detection unit (detector, high-voltage bypass, connections, signal cable, etc.), and from the light pulse. Taking into account the response of the oscilloscope, this leads to a signal delivered by the detection unit of z 7 0 ps FWHM. It is also worth noting that the light source-detection unit combination is able to deliver short pulses of more than one hundred volts.6 Indeed the maximum current of the photodiode in the linear region is m3 amperes; pulses of 150 volts amplitude and 70 ps FWHM can thus be obtained. of the oscilloscope and the useful vertical scan length (= 2 om). 6 The amplitude of the pulse displayed in Fig. 4 is limited by the bandwidth Absfracf-Observation of eleven unknown spontaneous spectral lines explains the appearance of corresponding laser lines.
Journal of the Optical Society of America, Jul 1, 1964
Se presenta en esta comunicación una nueva técnica holográfica por doble exposición, para el estu... more Se presenta en esta comunicación una nueva técnica holográfica por doble exposición, para el estudio de deformaciones colocando un interferograma entre el objeto a analizar y un me dio de registro fotográfico. Este novedoso método permite la obtención simultánea de los datos cuantitativos y de la estruc tura topográfica de la deformación. Se destaca su simplicidad,

New results obtained in spontaneous xenon spectrum employing a conventional pulsed gaseous laser ... more New results obtained in spontaneous xenon spectrum employing a conventional pulsed gaseous laser tube as light source, are presented in this work. A total of 626 spectral lines has been ionically assigned as follows: 50 to Xe 11 spectrum, 103 to Xe 111 spectrum, arid 222 to Xe IV spectrum. 30 Lines previously assigned to Xe II were reassigned as belonging to Xe 111, 94 lines were assigned with some doubts to Xe 11-111 spectrum. and 84 lines to Xe Ill-IV spectrum. Also there were classified 43 lines of Xe 11. RESUMEN Nuevos resultados obtenidos en el espectro del xenon espontaneo logrado mediante la utilizacion de un tuba de laser gaseoso pulsarlo convencional coma fuente de luz son presentados en este trabajo. Han sido estudiadas en total 626 I ineas espectrales las que fueron asignadas ionicamentP. de la sigu,ente manera: 50 al espectro del Xe II. 1"03 al de Xe Illy 222 al de Xe IV. 30 Lineas asignadas anteriormente al Xe II fueron reasignadas como pertP.necientes al Xe Ill. 94 Lineas fueron asignarlas con cierta duda al espectro del Xe 11-111 y 84 I ineas al de Xe 111-IV. Fueron clasificadas ademas 43 lineas del Xe II.

1. H ID D E N G R ID S A N D M O IR E P A T T E R N S Various methods exist to make photocopies o... more 1. H ID D E N G R ID S A N D M O IR E P A T T E R N S Various methods exist to make photocopies o f an original image. Photocopies are produced on opaque paper or transparent plastic sheets The original image can also be a slide that is projected onto the photocopier window or scanned. Each method has its proper form to generate the copied image. In general, matrix o f equally or stochastically spaced points or equally spaced lines are employed to reproduce half tones and colours. Figure 1 show's these two types o f hidden grids observed under microscope. Also, Figure 1 shows the Fraunhofer diffraction patterns o f both grids. The light sources used were a 15 cm k>sg filament lamp and a fluorescent tube. The matrix of points of the array o f lines can be considered as hidden grids that are incorporated to the image through the pkrtocopy process. Hidden grids can be used to encode information into the reproduced image in order to characterize some properties o f the original o...
Physics Letters A, 1969
... 5. G. Bennewitz and W. Paul, Z. Physik 139 (1954) 489. ... ON THE INTERACTION BETWEEN THE FIR... more ... 5. G. Bennewitz and W. Paul, Z. Physik 139 (1954) 489. ... ON THE INTERACTION BETWEEN THE FIRST AND SECOND POSITIVE LASER SYSTEMS IN N2 M. GA VAGLIA *, M. GALLARDO and CA MASSONE Departamento de F sica, Universidad Nacional de la Plata, La Plata ...
sedoptica.es
ABSTRACT: A Continuous Position Detector (CPD) is used to determine the position of the laser bea... more ABSTRACT: A Continuous Position Detector (CPD) is used to determine the position of the laser beam spot centroid. Comparison between CPD and CCD performances are analyzed. The light tracking instrument developed is introduced. Various applications of CPD light ...
Springer Series in Optical Sciences, 1981

Usualmente llamamos "biopsia" a un procedimiento médico invasivo mediante el cual se toma una mue... more Usualmente llamamos "biopsia" a un procedimiento médico invasivo mediante el cual se toma una muestra de tejido y se remite al laboratorio de patología para su análisis con fines diagnósticos. A diferencia de ésta, una "biopsia óptica" es un procedimiento no invasivo de diagnóstico, en el que se que realiza un análisis del tejido con un sistema óptico mediante técnicas láser, infrarrojo, fluorescencia, espectroscopías, microscopías, entre otras. Es decir, no se extrae una muestra del tejido del organismo. Al tejido a analizar se accede a través de la superficie del cuerpo, (incluido el análisis de la propia piel), o por vía endoscópica a la superficie de la mucosa de cualquier cavidad. Sus principales ventajas respecto de la biopsia convencional se centran en evitar tanto la posibilidad de diseminación de células malignas cuanto los retardos propios de la biopsia convencional. Esto es primordial en los casos que el diagnóstico rápido de malignidad permite un tratamiento inmediato, ya que esta técnica realiza in-situ el análisis de los cambios bioquímicos de los tejidos de pacientes. No obstante se requiere un exhaustivo trabajo de investigación para correlacionar los resultados de la biopsia convencional con los de la biopsia óptica antes de implementar un servicio que sólo atienda a los pacientes por biopsias ópticas. En el presente trabajo se describe la técnica de Espectroscopía Óptica de Fluorescencia y los resultados de algunos estudios preliminares de biopsias ópticas realizadas mediante ésta, (en particular la autofluorescencia), comparando la fluorescencia natural del tejido sano y del tejido patológico, de manera de contribuir al diagnóstico médico.
Fil: Garavaglia, Mario Jose. Consejo Nacional de Investigaciones Cientificas y Tecnicas. Centro C... more Fil: Garavaglia, Mario Jose. Consejo Nacional de Investigaciones Cientificas y Tecnicas. Centro Cientifico Tecnologico la Plata. Centro de Investigaciones Opticas (i); Argentina. Universidad Nacional de La Plata; Argentina. Provincia de Buenos Aires. Gobernacion. Comision de Investigaciones Cientificas; Argentina
En este trabajo se caracteriza radiométrica y fotométricamente una fuente de luz que emite con un... more En este trabajo se caracteriza radiométrica y fotométricamente una fuente de luz que emite con una longitud de onda nominal de 405 nm y se analiza el efecto fotodinámico sobre células HeLa (de cáncer de cérvix humano) empleando como fotosensibilizador la temoporfirina Foscan®. La intensidad de luz emitida por la fuente empleada cumple con la ley del cuadrado de la distancia y la absorción depende de la concentración. Las curvas de mortalidad celular frente al tratamiento fotodinámico (porcentaje de células muertas) se correlaciona con la cantidad de luz absorbida, siendo significativamente más efectivo el tratamiento con luz de de 405 nm en comparación con luz roja a igual fluencia (J cm-2). Los resultados obtenidos son alentadores para el desarrollo de nuevas fuentes de iluminación útiles para ciertas neoplasias.
This paper describes an alternative method for imaging the bile ducts during Cholecystectomy. X-R... more This paper describes an alternative method for imaging the bile ducts during Cholecystectomy. X-Rays are not needed. Positive results in open cholecystectomy are shown and the design of an IR endoscope is evaluated.
Uploads
Papers by Mario Garavaglia