Papers by Dominique Morau
Les dispositifs Mur Trombe ont fait l'objet de nombreuses etudes en climat tempere et ont pro... more Les dispositifs Mur Trombe ont fait l'objet de nombreuses etudes en climat tempere et ont prouve leur efficacite en tant que systeme de chauffage passif. Vis a vis du detail de la modelisation associee, un couplage fin (car faisant intervenir plusieurs modes de transfert) entre la piece et le dispositif est necessaire. Avec CODYRUN developpe a l'Universite de La Reunion, des resultats de simulation sont presentes au depart d'un fichier meteorologique et d'un habitat type de Madagascar. Ces murs capteurs stockeurs s'averent pouvoir ameliorer notablement les conditions de confort En utilisant des sorties specifiques (debits enthalpiques, apports par conduction, indices de confort, ... ), une analyse de l'efficacite du dispositif est menee et demontre les avantages de ce mode de chauffage passif et peu onereux.

The GEEB Team of the University of Reunion directed this research towards the optimization of the... more The GEEB Team of the University of Reunion directed this research towards the optimization of the anaerobic digestion of solid and liquid waste by injection of leachate. The objectives are to assess the performances of this type of process (to accelerate the process of biological breakdown) and to require a better control of the physicochemical mechanisms involved. During anaerobic digestion, the reactional medium desiccates and induces a deceleration of the process. The injection of leachate methanogene makes it possible to humidify the medium and to maintain the medium reactional under ideal physicochemical and biochemical conditions and to bring an additional organic load. In this paper, the optimization of the process of Co-digestion is presented through an experimental and a theoretical study. The experimentation is carried out on 10L laboratory bioreactors and is based on obtaining leachate methanogene by using liquid waste (STEP mud, liquid pig manure, residuary liquor) and s...

Cette etude s'est focalisee sur l'opportunite de l'utilisation des ressources renouve... more Cette etude s'est focalisee sur l'opportunite de l'utilisation des ressources renouvelables, comme le bois, dans le domaine energetique. La modelisation de chaque etape de transformation de l'energie des residus bois en electricite est presentee : transformation du bois en gaz de synthese par le biais d'un gazogene – conversion de l'energie calorifique du syngaz en energie mecanique par l'utilisation d'un moteur a combustion interne – conversion de l'energie mecanique en energie electrique avec l'aide d'un alternateur. Pour cela, des modeles pour chaque procede ont ete mis en place. Pour l'etude energetique, le concept de l'exergie et de l'analyse exergetique ont ete prefere dans ce travail. La fiabilite des modeles est validee par des comparaisons avec des donnees experimentales. Une analyse de sensibilite par l'utilisation de l'algorithme automatise de GoSAT est faite pour l'etude des parametres des modeles.
Presentation about Monitoring anaerobic co-digestion of waste through the characterization of lea... more Presentation about Monitoring anaerobic co-digestion of waste through the characterization of leachates by near infrared spectroscopy

De nos jours, la protection de l'environnement est un defi international. Le toit vert est l&... more De nos jours, la protection de l'environnement est un defi international. Le toit vert est l'un des concepts innovants pour f aire face a cette bataille. On observe une augmentation de son utilisation dans les zones urbaines a travers le monde. Mais une question se pose : quelles sont les consequences sur l'environnement du cycle de vie du toit vert ? Dans cet article, les performances environnementales de deux systemes complets de toits verts leger et lourd implantes a Antananarivo-Madagascar sont analysees et comparees dans le but de determiner les impacts potentiels des deux systemes de toit vert. Des solutions sont avancees pour diminuer les charges environnementales des toits verts. L'approche d'Analyse de Cycle de Vie (ACV) a ete utilisee pour realiser l'etude. Les differentes phases de l'approche : 1-definition des objectifs, 2-inventaire de cycle de vie, 3-caracterisation des impacts, 4-interpretation des resultats, ont ete deroulees sur le system...

La gazeification de la biomasse est un procede de conversion tres prometteur pour la production d... more La gazeification de la biomasse est un procede de conversion tres prometteur pour la production de gaz de synthese ou syngas, compose essentiellement de dioxyde de carbone, de monoxyde de carbone, d’hydrogene et de methane, et se presente comme etant une technologie alternative a l’utilisation des energies fossiles conventionnelles. Le present travail porte sur la modelisation de la conversion thermochimique de la biomasse par gazeification et du comportement des mecanismes reactionnels dans un reacteur a lit fluidise a deux phases, solide et gazeuse. Pour ce faire, un modele mathematique base sur une approche hydrodynamique de type Euler-Lagrange est developpe. Les equations de conservation de masse, de quantite de mouvement, de l’energie et de transport des especes ainsi que les reactions chimiques decrivant le processus de gazeification y sont notamment incluses. Le modele est resolu numeriquement par la methode des volumes finis conservative sur la plateforme OpenFOAM. Une analy...
This paper describes the dynamic modeling of a solar absorption cooling plant that will be built ... more This paper describes the dynamic modeling of a solar absorption cooling plant that will be built for both research and demonstration purposes by the end of 2007. The synchronizing of cooling loads with solar radiation intensity is an important advantage when utilizing solar energy in air conditioning in buildings. The first part of this work deals with the dynamic modeling of an evacuated tube collector. A field of these collectors feed a single-effect absorption chiller of 35 kW nominal cooling capacity. The simulation model has been done in a modular way under TRNSYS16. In a second part, simulation and ptimization of the system has been investigated in order to determine the effect of several parameters (collector area, tank volume...) on chiller performance.

The GEEB Team of the University of Reunion directed this research towards the optimization of the... more The GEEB Team of the University of Reunion directed this research towards the optimization of the anaerobic digestion of solid and liquid waste by injection of leachate. The objectives are to assess the performances of this type of process (to accelerate the process of biological breakdown) and to require a better control of the physicochemical mechanisms involved. During anaerobic digestion, the reactional medium desiccates and induces a deceleration of the process. The injection of leachate methanogene makes it possible to humidify the medium and to maintain the medium reactional under ideal physicochemical and biochemical conditions and to bring an additional organic load. In this paper, the optimization of the process of Co-digestion is presented through an experimental and a theoretical study. The experimentation is carried out on 10L laboratory bioreactors and is based on obtaining leachate methanogene by using liquid waste (STEP mud, liquid pigmanure,residuary liquor) and sol...

One of the virtues of watercress is its ability to grow in wastewater. This work aims at experime... more One of the virtues of watercress is its ability to grow in wastewater. This work aims at experimentally studying the thermal behavior of a watercress planted roofed cubic cell. To do this, the temperatures of various components of the cell and the solar radiation received by this cell were measured in order to compare the watercress roof performance with that of the conventional concrete roof. Then, the influence of the opening applied on the door of the studied cell was analyzed. As results, the fluctuation amplitude of the indoor ambient temperature of the concrete roofed cell is wider than that of the green roofed cell. Moreover, the last opening applied to the facades of the cell was the optimum area that the ambient temperature indoor was more attenuated. The LAI’s crop was worth 1.2. In addition, the low value of the canopy apparent thermal conductivity revealed that this layer plays a role of thermal insulation. The rooftop greening allows energy savings of about 85% Original...
This paper describes the dynamic modeling of a solar absorption cooling plant that will be built ... more This paper describes the dynamic modeling of a solar absorption cooling plant that will be built for both research and demonstration purposes by the end of 2007. The synchronizing of cooling loads with solar radiation intensity is an important advantage when utilizing solar energy in air conditioning in buildings. The first part of this work deals with the dynamic modeling of an evacuated tube collector. A field of these collectors feed a single-effect absorption chiller of 35 kW nominal cooling capacity. The simulation model has been done in a modular way under TRNSYS16. In a second part, simulation and optimization of the system has been investigated in order to determine the effect of several parameters (collector area, tank volume...) on chiller performance.
Renewable and Sustainable Energy Reviews

Http Www Theses Fr, 2006
Les attentes vis-à-vis de la gestion des déchets solides, des eaux usées aujourd'hui différent su... more Les attentes vis-à-vis de la gestion des déchets solides, des eaux usées aujourd'hui différent suivant les acteurs concernés : les ménages veulent se débarrasser des ordures et eaux usées pour une question de nuisance. Les collectivités locales se préoccupent de leur gestion dans le double souci de l'esthétique urbaine et de l'hygiène publique. Les opérateurs privés, tout en reconnaissant le caractère social du sujet, sont à la recherche de profit. Ces attentes posent un certain nombre de problèmes liés au souhait et à la difficulté à les intégrer, très partiellement résolues, dans un système global et abouti, ainsi qu'à l'optimisation de systèmes de gestion dans les contextes et situations spécifiques des villes. Un des principes d'une bonne gestion des déchets d'ailleurs réaffirmé dans la « Déclaration d'Abidjan » consiste en ce que la question des déchets soit abordée globalement en prenant en compte l'ensemble de la filière : collecte, évacuation, traitement. Mais les difficultés d'ordre technique, financier, social et institutionnel n'ont toujours pas permis d'étendre le service sur toutes ces séquences, sur toutes les populations et sur tout le territoire urbain en adéquation avec les ressources humaines, matérielles et financières disponibles ou mobilisables. De même, le souci de valoriser les déchets solides ou les effluents connaît un regain d'intérêt, non pas seulement dans le but d'améliorer l'environnement sanitaire, mais surtout dans une perspective gestionnaire pour soulager l'économie globale de la filière. L'intégration de cette valorisation à la filière de gestion des déchets solides et liquides a d'ailleurs des retombées tant sur les plans économiques et financiers, que techniques et organisationnels, ou sociaux.
International Science Journal for Alternative Energy and Ecology, 2007
This paper describes the dynamic modeling of a solar absorption cooling plant that will be built ... more This paper describes the dynamic modeling of a solar absorption cooling plant that will be built for both research and demonstration purposes by the end of 2007. The synchronizing of cooling loads with solar radiation intensity is an important advantage when utilizing solar energy in air conditioning in buildings. The first part of this work deals with the dynamic modeling of an evacuated tube collector. A field of these collectors feed a single-effect absorption chiller of 35 kW nominal cooling capacity. The simulation model has been ...
Uploads
Papers by Dominique Morau