10-year follow-up of immediately loaded implants with TiUnite porous anodized surface
- PMID: 22376174
- DOI: 10.1111/j.1708-8208.2012.00446.x
10-year follow-up of immediately loaded implants with TiUnite porous anodized surface
Abstract
Background: The immediate loading of implants with a porous anodized surface is a well-described technique. Few data are however available on the long-term outcomes.
Purpose: The aim of this prospective study was to assess the 10-year performance of TiUnite implants supporting fixed prostheses placed with an immediate loading approach in both postextractive and healed sites.
Materials and methods: All patients received a fixed provisional restoration supported by immediately loaded parallel design, self-tapping implants with a porous anodized TiUnite surface, and an external-hexagonal connection. Both healed and postextractive cases were included. Success and survival rate for restorations and implants, changes in marginal peri-implant bone level, probing depth measurements, biological or technical complications, and any other adverse event were recorded at yearly follow-up up to 10 years after surgery.
Results: A total of 210 implants fulfilled the inclusion criteria and were consecutively placed in 59 patients. Forty-seven (22.38%) implants were lost because of the recalled patient refused to attend the planned 10-year follow-up. Five over 210 (2.38%) implants were lost. At the final follow-up, the accumulated mean marginal bone loss and probing depth were, respectively, 1.93 mm (SD 0.40) and 2.54 mm (SD 0.44) for the implants placed in healed sites (n = 84); 1.98 mm (SD 0.37) and 2.63 mm (SD 0.39) for the implants placed in postextractive sites (n = 74). The restorations examined achieved a cumulative 65.26% success rate and 97.96% survival rate. The implants placed in healed and postextractive sites, respectively, achieved a 98.05% and a 96.52% cumulative survival rate.
Conclusions: Positive results in terms of bone maintenance in the long-term perspective are to be expected using immediately loaded implants with a TiUnite porous anodized surface in both postextractive and healed sites when adequate levels of oral hygiene are kept.
© 2012 Wiley Periodicals, Inc.
Similar articles
-
Immediate loading of tapered implants placed in postextraction sockets: retrospective analysis of the 5-year clinical outcome.Clin Implant Dent Relat Res. 2012 Aug;14(4):565-74. doi: 10.1111/j.1708-8208.2010.00297.x. Epub 2010 Jul 17. Clin Implant Dent Relat Res. 2012. PMID: 20662861
-
10-year prospective cohort follow-up of immediately restored XiVE implants.Clin Oral Implants Res. 2016 Jun;27(6):694-700. doi: 10.1111/clr.12642. Epub 2015 Jun 21. Clin Oral Implants Res. 2016. PMID: 26096295
-
Six-Year Radiographic, Clinical, and Soft Tissue Outcomes of Immediately Loaded, Straight-Walled, Platform-Switched, Titanium-Alloy Implants with Nanosurface Topography.Int J Oral Maxillofac Implants. 2016 Jan-Feb;31(1):167-71. doi: 10.11607/jomi.4162. Int J Oral Maxillofac Implants. 2016. PMID: 26800174
-
Anodized dental implant surface.Indian J Dent Res. 2017 Jan-Feb;28(1):76-99. doi: 10.4103/ijdr.IJDR_386_16. Indian J Dent Res. 2017. PMID: 28393822 Review.
-
To evaluate the effect of anodized dental implant surface on cumulative implant survival and success. A systematic review and meta-analysis.J Indian Soc Periodontol. 2022 Nov-Dec;26(6):525-532. doi: 10.4103/jisp.jisp_797_20. Epub 2022 Nov 14. J Indian Soc Periodontol. 2022. PMID: 36582952 Free PMC article. Review.
Cited by
-
Effects of thermal treatment on the adhesion strength and osteoinductive activity of single-layer graphene sheets on titanium substrates.Sci Rep. 2018 May 25;8(1):8141. doi: 10.1038/s41598-018-26551-w. Sci Rep. 2018. PMID: 29802306 Free PMC article.
-
Latest Trends in Surface Modification for Dental Implantology: Innovative Developments and Analytical Applications.Pharmaceutics. 2022 Feb 21;14(2):455. doi: 10.3390/pharmaceutics14020455. Pharmaceutics. 2022. PMID: 35214186 Free PMC article. Review.
-
Achievements in the Topographic Design of Commercial Titanium Dental Implants: Towards Anti-Peri-Implantitis Surfaces.J Clin Med. 2019 Nov 14;8(11):1982. doi: 10.3390/jcm8111982. J Clin Med. 2019. PMID: 31739615 Free PMC article. Review.
-
Clinical and Radiographic Evaluation of Brånemark Implants with an Anodized Surface following Seven-to-Eight Years of Functional Loading.Int J Dent. 2013;2013:583567. doi: 10.1155/2013/583567. Epub 2013 Mar 7. Int J Dent. 2013. PMID: 23533412 Free PMC article.
-
Recent advances in dental implants.Maxillofac Plast Reconstr Surg. 2017 Nov 5;39(1):33. doi: 10.1186/s40902-017-0132-2. eCollection 2017 Dec. Maxillofac Plast Reconstr Surg. 2017. PMID: 29159171 Free PMC article. Review.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources