Skip to the content.

OT-Security-Lab: Integrated Industrial Control System (ICS) Security Environment

Compliance Framework License: MIT CI Compliance Gate Site Contributing Security

Live demo — the SOC dashboard and a cold-boot make compliance run:

OT-Security-Lab demo: the live SOC dashboard and the compliance suite

Rendered from a real run: evidence/demo.mp4 · reproducible via docs/media/capture-demo.sh.

Recorded on an earlier 14-check run; the current gate adds the PowerShell and OT service-port scan scenarios.

Category Specification
Industry Water Treatment & Filtration
Frameworks IEC 62443, MITRE ATT&CK for ICS, ISA-95 Purdue Model
Environment 5-Zone Segmented Docker Lab (Enterprise, Industrial DMZ, Operations, Supervisory, Control) + simulated L0
Monitoring Protocol-aware anomaly detection (Modbus/TCP, DNP3, OPC UA, S7comm)
Evidence Verified Attack Simulation Logs

At a glance

16/16 automated compliance checks pass on a cold boot (make compliance): the gate boots the whole lab, samples the benign steady state, replays the attack scenarios, and asserts both the JSON alert and the matching Loki ruler rule for each protocol scenario.

Check What it proves
Benign Baseline The idle lab (no attacks) produces zero false OT alerts
Cross-Zone Violation IT → Control traffic is dropped by the gateway firewall and detected
Unauthorized Modbus Write A write from an unauthorized source is detected
Modbus Brute-Force Scan Reconnaissance against Modbus is detected
Lateral Movement East-west movement inside the plant is detected
HMI Login Brute Force Repeated failed logins raise HMI_LOGIN_FAILURE
Physics-Aware Safety Violation An unauthorized write moves the real process out of its safe band
DNP3 Adversary Emulation Unauthorized control, restart and unsolicited-disable are detected
OPC UA Adversary Emulation Browse, write and method-call are detected
S7comm Adversary Emulation Program download/upload and operating-mode change are detected
C2 Beaconing (blocked egress) Regular-interval blocked egress from the OT host is detected (C2_BEACON, stateful)
Detection-Service Watchdog A stopped detection producer raises DETECTION_SERVICE_DOWN
Historian Ingestion Modbus → L2 collector → InfluxDB → Grafana is live end to end
Remote Engineering Hop bastion → EWS over conduit C11 (key-only SSH) is reachable
PowerShell Adversary Emulation A PowerShell 7 FC6 write from the L2 operator workstation raises UNAUTHORIZED_MODBUS_WRITE
OT Service-Port Scan A SYN scan across Modbus/S7comm/DNP3/OPC UA ports raises OT_PORT_SCAN
Metric Value
Detection types in the live evidence 17
ICS protocols covered 4 (Modbus/TCP, DNP3, OPC UA, S7comm)
IEC 62443-3-3 implementation score 72.7% across 12 requirements
Automated tests 130 (116 pytest + 14 Pester)
CI gates (+ Compliance Gate) 13
Zones / active conduits 5 / 10

Every number traces to an artifact and, where possible, an automated check — see CLAIMS.md. The authoritative runtime evidence is evidence/runtime_evidence.json (machine-generated from the running lab by governance/testing/capture_evidence.py); the derived board-level figures are in governance/executive/executive-summary.md; the checks themselves run in .github/workflows/compliance-gate.yml.

Project Overview

This repository contains a full-scale, simulated industrial environment designed to demonstrate the implementation of robust security controls within an Operational Technology (OT) context. The project encompasses the entire lifecycle of an IT/OT Security Engineer’s responsibilities: from architectural design and network segmentation based on the Purdue Model, to threat modeling, detection engineering, and IEC 62443 compliance mapping.

The lab simulates a Water Treatment & Filtration Facility, facilitating a hands-on platform for validating security configurations and detection rules against realistic ICS attack vectors.


2. Architecture: The Purdue Model

The environment is segmented into logical levels according to the ISA-95 Purdue Model, ensuring strict isolation of critical control processes.

graph TD
    %% Level Definition
    subgraph L4_5 ["Level 4 & 5: Enterprise"]
        A[Attacker Simulation]
        B[Corporate Workstation]
    end

    subgraph DMZ ["Industrial DMZ"]
        JH[Jump Host / Bastion]
        RP[Reverse Proxy]
    end

    subgraph L3 ["Level 3: Operations"]
        C[Historian - InfluxDB]
        D[Engineering Workstation]
    end

    subgraph L2 ["Level 2: Supervisory"]
        E[SCADA / HMI Server]
    end

    subgraph L1 ["Level 1: Control"]
        F1[PLC-01: Intake]
        F2[PLC-02: Treatment]
        F3[PLC-03: Distribution]
    end

    subgraph L0 ["Level 0: Field Devices"]
        G[Sensors/Actuators]
    end

    %% Conduits
    B ---|VPN/HTTPS| JH
    JH ---|RDP/SSH| D
    D ---|S7/Modbus| F1
    E ---|Modbus/TCP| F1
    E ---|Modbus/TCP| F2
    E ---|Modbus/TCP| F3
    F1 ---|Process Flow| F2
    F2 ---|Process Flow| F3
    F3 ---|Hardwired| G

    %% Styling
    style DMZ fill:#fff2cc,stroke:#d6b656,stroke-width:2px
    style L1 fill:#fdb,stroke:#333,stroke-width:2px

Purdue Levels Mapping:

Note: the Industrial DMZ is implemented: a jump host/bastion (ot_bastion, SSH) and a reverse proxy (ot_reverse_proxy) publish the operator interface to the Enterprise zone, and a corporate workstation exercises the DMZ access path. The gateway enforces the DMZ conduits (C9/C10). L0 field devices are simulated by the controllers.


3. Table of Contents

  1. Architecture & Design
  2. Lab Environment
  3. Asset Inventory
  4. Threat Model & Risk Analysis
  5. Detection & Monitoring
  6. Key Findings & Engineering Judgments
  7. Getting Started
  8. Technologies Used
  9. Known Limitations & Future Work
  10. Compliance Mapping

Physics-Aware Violation Demo

Integrated SIEM Dashboard (Loki & Grafana)

SOC Overview Dashboard

Forensic Log Analysis (MITRE ATT&CK Mapping)

Loki Raw Logs

The images above are illustrative UI snapshots. The authoritative runtime evidence is evidence/runtime_evidence.json — machine-generated from the running lab (Loki alert counts by type, ruler rule states, Grafana datasources, historian last values) by governance/testing/capture_evidence.py. Regenerate it after make up.


4. Governance, Risk & Compliance (GRC)

To bridge the gap between technical implementation and industrial standards (Exceltic/ISA-62443 requirements), this lab includes formal documentation:


5. Scalability & Protocol Realities

The lab implements Modbus/TCP, DNP3, OPC UA and S7comm with protocol-aware detection on real endpoints. In a production rollout (e.g., Railway/Transportation):


6. Key Findings & Engineering Judgments


6.1 Adversary Emulation & Detection Validation

The lab validates detections through three complementary paths:

Path What it proves How to run
Deterministic BAS harness Every scenario produces the expected JSON alert and Loki ruler state, including a benign baseline make compliance
PowerShell 7 scenario A real FC6 write from the L2 operator workstation is detected as UNAUTHORIZED_MODBUS_WRITE docker exec ot_powershell pwsh -File /opt/otsec/Invoke-OTAdversaryEmulation.ps1 -Scenario UnauthorizedWrite -Target 172.21.0.10 -AllowLab
MITRE Caldera (optional) The same OT TTPs can be orchestrated through a recognised BAS/emulation platform make caldera-image && make caldera

The PowerShell toolkit lives in powershell/ and is tested with Pester and PSScriptAnalyzer in CI. The tooling comparison, including the AttackIQ Academy path, is in docs/adversary-emulation.md. The optional Caldera profile lives in lab-environment/caldera/; it is deliberately excluded from the default boot and the compliance gate. The first operation and its detection gaps are documented in the purple-team report.


7. Getting Started

To spin up the entire simulated environment (OpenPLC, HMI, Historian, and Firewall):

# Clone the repository
git clone https://github.com/LiamCarPer/OT-Security-Lab.git
cd ot-security-lab

# Start the environment (firewall rules and IDS rules apply automatically)
make up

# Validate the environment: simulate attacks and assert detection
make compliance

The gateway container applies the IEC 62443 zone firewall on boot and launches all custom detection rules as persistent services (make up is sufficient; no manual docker cp/docker exec steps are required).

Optional adversary-emulation control plane (large image, built on demand):

make caldera-image   # build Caldera 5.3.0 once
make caldera         # start Caldera + the attacker Sandcat agent
# UI: http://localhost:8888 (red / ot-lab-caldera; API key ot-lab-caldera-api)

The default stack and the compliance gate do not depend on Caldera. See lab-environment/caldera/README.md.

The OpenPLC runtimes are headless: each runs a committed program.zip under plc/programs/, built automatically by plc/build.sh from the ST sources with the STruC++ toolchain (no desktop editor required), then uploaded at boot by the EWS bootstrap service. The controllers run real IEC 61131-3 logic and serve the canonical register map over Modbus/TCP; the physics-aware detection therefore observes the live process. See plc/programs/README.md.

Run in Codespaces (one click)

No local Docker required — the whole lab runs in your browser:

  1. Open the repository → Code → Codespaces → Create codespace on main.
  2. Pick the 4-core / 8GB machine type (the stack consumes ~4.3GB RAM).
  3. Wait for the automatic build and boot (first time ~5-10 min; progress is visible in the terminal). The devcontainer forwards: Grafana :3000 · SCADA HMI :8080 (via the DMZ reverse proxy) · Bastion SSH :2222 · Alertmanager :9093 · Caldera (optional profile) :8888. (The PLC runtime API is internal to the Control zone and reached by the EWS, so it is not host-published.)
  4. Validate the environment:
    make compliance
    

    This replays all attack simulations and asserts detection, then commits the fresh evidence back to detection/logs/alerts.json — which you can watch update live in the editor.


8. Technologies Used

8.1 CI/CD & Supply Chain


9. Known Limitations & Future Work

Current Limitations:

Future Roadmap:


10. Compliance Mapping