Papers by vedashree rajderkar
Comparison Between PID and SMC Controller to Control the Speed of DC Separately Excited Motor
Lecture notes in electrical engineering, 2024
Design of Closed loop Control of DC Seperatedly Excited Motor
Comparison of Series FACTS Devices Via Optimal Location in a Power System for Congestion Management
... [6] A.Kazemi, S. Jamali, M Habibi and S.Ramezan-Jamaat, " Optimal location of TCSCs in a... more ... [6] A.Kazemi, S. Jamali, M Habibi and S.Ramezan-Jamaat, " Optimal location of TCSCs in a power system by means of genetic algorithms considering loss reduction , IEEE power and energy conference 2006, pp 134-139,28-29 Nov. 2006. ...
Single phase Cascaded H-Bridge Multilevel Inverter Topology
Enhancement of Power System Security by Fuzzy based Unified Power Flow Controller
2022 2nd International Conference on Intelligent Technologies (CONIT), Jun 24, 2022

Optimum Location of Thyristor Controlled Phase Angle Regulator Based on Performance Index
Nowadays the overloading of the transmission lines are increased due to which different types of ... more Nowadays the overloading of the transmission lines are increased due to which different types of faults and the main issue i.e., voltage collapse may occurs which affect the stability of the system. Thus the main objective of the system operator is to maintain the system in steady state limit. Flexible AC Transmission System (FACTS) devices plays a vital role in maintaining the power system stability, reducing the overall system losses and controlling the power flow in the system. But it is very necessary to investigate the optimal location of these FACTS devices for their satisfactory operation. In this paper, the optimum location of the thyristor controlled phase angle regulator (TCPAR) has been figure out in the system based on real power flow performance index (PI). The test case of IEEE -5 bus system is to be considered and the power flow of the system is carried out by using MATLAB. The results of MATLAB are verified with the power world simulator 12.0 software.
IACSIT international journal of engineering and technology, 2012
In stressed electric power systems, due to increased loading or due to severe contingencies often... more In stressed electric power systems, due to increased loading or due to severe contingencies often lead to situation where system no longer remains in the secure operating region. FACTS devices can play very important role in power system security enhancement. Due to high capital investment, it is necessary to locate these devices optimally in the power system. The scope of this paper is to decide optimal location of Thyristor controlled series compensator (TCSC) by a real power flow performance index sensitivity based approach & line outage distribution factor. The effectiveness of the proposed controller has been tested on modified IEEE 30 bus system using Power world simulator software version 12.0.

Optimal Location of Series FACTS Devices for Enhancing Power System Security
In emerging electric power systems, due to increased loading or due to severe contingencies often... more In emerging electric power systems, due to increased loading or due to severe contingencies often lead to situation where system no longer remains in the secure operating region. Under these situations, it is primary objective of the operator to apply control action to bring the power system into the secure region. FACTS devices can play a very important role in power system security enhancement. Due to high capital investment, it is necessary to locate these devices optimally in the power system. In this paper, a real power flow performance index (PI) sensitivity based approach and the line outage distribution factor has been proposed to decide optimal location of Thyristor Controlled Series Compensator (TCSC) and Static Synchronous Series Compensator (SSSC) to enhance the security of the power system. The effectiveness of the proposed controller has been tested on modified IEEE 30 bus system using Power World Simulator Software Version 12.0.
International journal of engineering research and technology, Apr 29, 2019
All the conventional energy resources are exhausting. So it is necessary to shift from convention... more All the conventional energy resources are exhausting. So it is necessary to shift from conventional to non-conventional energy resources. In the proposed work we have done combination of two energy sources for streetlight system. This process reviles the sustainable energy resources without damaging the nature. Basically this is a hybrid system which involves the integration of two energy system that will give continuous power. Solar panels are used for converting solar energy and wind turbines are used for converting wind energy into electricity. This electrical power can utilize for various purpose. The purpose of this proposed system is generation of electricity at affordable cost.

Engineering, Technology & Applied Science Research
The electricity demand is continuously increasing, so a most efficient use of the current power s... more The electricity demand is continuously increasing, so a most efficient use of the current power system's capacity is desired. Flexible AC Transmission Systems (FACTSs), a recently developed transmission technology, are widely used to boost the power transfer ability of long-distance transmission line networks and to enhance the consistency of the transmission systems. The use of FACTS devices can lead to reduced flows on heavily loaded lines, targeted bus voltage levels, and better power network stability. In this study, an optimization method based on the optimal position of the Unified Power Flow Controller (UPFC) is suggested to boost system security. It is decided that the real power flow is the best place for the UPFC in this instance. The optimal placement during congestion has been determined using the Genetic Algorithm (GA) and the sensitivity to the useful power flow index. Congestion is produced on the network and system performance is evaluated. The proposed solutions...
Single phase Cascaded H-Bridge Multilevel Inverter Topology
2022 International Conference on Futuristic Technologies (INCOFT)

Allocation of Unified Power Flow Controller(UPFC) through sensitivity approach for Enhancing the system performance
2021 6th International Conference for Convergence in Technology (I2CT)
In a Modern power system network, Congestion may occurs due to lack of coordination between deman... more In a Modern power system network, Congestion may occurs due to lack of coordination between demand and supply so as to increase the stress on the existing transmission utilities. The system no longer operates within its thermal limit. Unified power flow controller (UPFC) plays a very important role in the power network to enhance the performance of existing lines as well as to improve the security of the system. UPFC should be located optimally due to high capital investment. In this paper, the allocation of UPFC is obtained by sensitivity based approach in terms of change in active power flow sensitivity index so as to enhance the system performance and The test results has been implemented in the MATLAB with modified IEEE 30 bus network and the performance of the system is validated by Power World Simulator Software 16.0.

Impact of Thyristor Controlled Phase Angle Regulator on Power Flow
Due to increased loading or severe faults in power system results into stressed power system, it ... more Due to increased loading or severe faults in power system results into stressed power system, it will arise the situation in which system does not remains in secure operating region. Therefore, it is the first aim to make methodology to bring power system again into secure operating region. If there will be an unavailability of proper methodology to bring the system into secure region it leads to unstable power system. Similarly in power system the severe faults results into voltage collapse and it decreases the voltage limits which leads overloading of lines. This condition can be overcome by two options i.e. by reconstruction of power system or adjusting the line parameters. In modern days Flexible AC Transmission System (FACTS) are used which controls different parameters of the power system and makes power system stable & improves its performance. Among the FACTS devices the Thyristor Controlled Phase Angle Regulator (TCPAR) plays an important role in increasing load ability of ...
1 Research-scholar, Dept. of Electrical Engineering, G.H.R.C.E, Nagpur, India 2 Assistant Profess... more 1 Research-scholar, Dept. of Electrical Engineering, G.H.R.C.E, Nagpur, India 2 Assistant Professor, Dept. of Electrical Engineering, G.H.R.C.E, Nagpur, India ---------------------------------------------------------------------***--------------------------------------------------------------------Abstract This paper focuses on scalar control technique which is also known as constant v/f control technique. This paper presents the improvement in the performance by the use of DSP TMS320F2812. This method gives the précised output after the application of load to the induction motor. Matlab simulink software is used for making simulation and the results are obtained by performing the experimental setup.

Optimum Location of Thyristor Controlled Phase Angle Regulator Based on Performance Index
2018 International Conference on Smart Electric Drives and Power System (ICSEDPS), 2018
Nowadays the overloading of the transmission lines are increased due to which different types of ... more Nowadays the overloading of the transmission lines are increased due to which different types of faults and the main issue i.e., voltage collapse may occurs which affect the stability of the system. Thus the main objective of the system operator is to maintain the system in steady state limit. Flexible AC Transmission System (FACTS) devices plays a vital role in maintaining the power system stability, reducing the overall system losses and controlling the power flow in the system. But it is very necessary to investigate the optimal location of these FACTS devices for their satisfactory operation. In this paper, the optimum location of the thyristor controlled phase angle regulator (TCPAR) has been figure out in the system based on real power flow performance index (PI). The test case of IEEE -5 bus system is to be considered and the power flow of the system is carried out by using MATLAB. The results of MATLAB are verified with the power world simulator 12.0 software.

Growth in load demand may lead to changes in generation sources and sizes along with all the unce... more Growth in load demand may lead to changes in generation sources and sizes along with all the uncertainty of transactions will further strain existing power systems, and may lead to the transmission systems to work closer to their operating limits or even beyond its transfer capacity and cause congestion. Applications of newly emerging technologies are able to provide solutions for electricity markets to maintain the stability and reliability of power systems while handling large volumes of transactions. FACTS allows flexible operation of AC transmission systems whereby the changes can be accommodated very easily without stressing the system. In this paper the proposed methods are illustrated with a IEEE 30-bus system to improve the congestion management and to reduce the operating cost of the system using STATCOM controller. The optimal location as well as optimal rating of the device is found out for optimal system using Power World Simulator Software 12.0.
Thyristor Controlled Series Compensator to Resolve Congestion Caused Problems
2010 3rd International Conference on Emerging Trends in Engineering and Technology, 2010
... [4]. A. Kazemi, S. Jamali, M Habibi and S. Ramezan Jammt, Optimal location of TCSCs in a ... more ... [4]. A. Kazemi, S. Jamali, M Habibi and S. Ramezan Jammt, Optimal location of TCSCs in a power system by means of genetic algorithms considering loss reduction, IEEE power and energy conference 2006, pp 134-139, 28-29 Nov.2006. ...

2011 International Conference on Emerging Trends in Electrical and Computer Technology, 2011
In this study, a new multilevel inverter configuration which introduces a combination of cascaded... more In this study, a new multilevel inverter configuration which introduces a combination of cascaded H-bridge multilevel inverter with a double level circuit is proposed. The double level circuit is a half-bridge inverter when combined with a cascaded H-bridge multilevel inverter, will increase the output voltage level to nearly twice that of a conventional cascaded H-bridge multilevel inverter. The effectiveness of the proposed configuration is demonstrated with five different cases of cascaded Hbridge multilevel inverter configurations. Phase disposition carriers arrangement with sinusoidal reference has been utilised in pulse width modulation for generating the gating signal of switches to achieve high-quality output voltage waveform. A comparison is carried out with different parameters such as %total harmonic distortion, distortion factor, the maximum voltage step of output voltage level and peak inverse voltage. Analysis of power loss and theoretical calculation of %total harmonic distortion is described. Also, a new method for calculating the overall component count is discussed. As a result, the proposed configuration requires lesser component count for generating higher output voltage level with lower %total harmonic distortion. Selected simulation and experimental results are shown to verify and validate the proposed multilevel inverter configuration.

International journal of power system operation and energy management, Jul 1, 2013
FACTS is one aspect of the power electronics revolution that is taking place in all areas of elec... more FACTS is one aspect of the power electronics revolution that is taking place in all areas of electric energy. FACTS devices can be an alternative to reduce the flows in heavily loaded lines, resulting in an increased loadability, low system loss, improved stability of the network, reduced cost of production and fulfilled contractual requirement by controlling the power flows in the network. This paper investigates a methodology for placement of thyristor controlled phase angle regulator (TCPAR) in order to relieve congestion in the transmission lines while increasing static security margin and voltage profile of a given power system. Sensitivity-Based Methodology is opted for finding the optimal location The effectiveness of the purposed methods is demonstrated on modified IEEE 30-bus system by using Power World Simulator Software version 12.0.

Engineering, Technology & Applied Science Research
In power networks, operation planning has become necessary due to the continuously increased load... more In power networks, operation planning has become necessary due to the continuously increased load demand. The Unified Power Flow Controller (UPFC) controls the power flow through the network and improves the dynamics of the power system. In this paper, the design application of the coordination of a fuzzy-based UPFC with hybrid energy storage has been proposed to enrich the system's dynamic performance during abnormal conditions and improve the hybrid energy storage performance during transients when the DC link voltage is insufficient to meet the converter voltage demand. The hybrid energy storage consists of a supercapacitor and a battery connected across the UPFC Vdc shunt capacitor. The proposed system to improve the UPFC performance during large disturbances on a multi-machine system was designed and tested in MATLAB/SIMULINK.
Uploads