Papers by kaouther el kourd
Detection of the boundary of an object in medical images, then the segmentation from the backgrou... more Detection of the boundary of an object in medical images, then the segmentation from the background class, is a major challenge in medical image processing. Active Contour Model, or Snake, which is a deformable model for approaching object boundaries, it is a curve defined within an image domain which can move under the influence of internal forces from the curve itself and external forces from the image data ; That's mean using different energy function B-Snake (GVF(s)) is able not only to grow through long and thin concavities but also it does not miss the correct boundaries.
In our work, we begin by translating a non linear m odel to linear one by using the numerical ana... more In our work, we begin by translating a non linear m odel to linear one by using the numerical analysis with Runge-Kutta4 (RK4). After that, we pass to the statistical study for linear regression then for the analysis of variance, “ ANOVA technique”, by applying the statistical study on t he pathological image to detect the tumors of multi MRI images. In the last, we compeer the result obtained for non li ear model with linear one.
American Scientific Research Journal for Engineering, Technology, and Sciences, 2015
In this paper we propose an iterative method (Gauss seidal technique (GS)) to detect the lesion ... more In this paper we propose an iterative method (Gauss seidal technique (GS)) to detect the lesion than compared with Matlab program for neuronal network (ANN technique), where we can see clearly the high level of detection for the both methods, but for accuracy time our propose with G S present an excellent time in front of ANN technique, The program used is Matlab.
L'objectif principal de notre travail est de faire un ajustement lineaire de la technique BOL... more L'objectif principal de notre travail est de faire un ajustement lineaire de la technique BOLD (Blood Oxygenation Level Dependent) de l'IRMf. Ce qui permet de mieux etudier et explorer cette technique. Celle ci comporte une reponse hemodynamique (hrf) dont la forme a ete choisie par Friston & Al en 1994[1] et qui depend du taux d'oxygene dans le sang, du debit et du volume sanguin .Pour cette raison on a applique une technique mathematique d'ajustement sur la base du modele lineaire;qui contient le bus de donnees des trames d'image (la serie temporelle) , la matrice experimentale , la regression ou bien les parametres voulus de l'estimation et Finalement l'erreur du calcul qui doit etre minimale. D'apres le modele lineaire et l'application de t-test Student on trouve une activite inferieure a 0.05. Ceci est visualise sur une glass de Talairach.
في هذه الورقة قمنا باستعمال طريقتين رياضيتين : الطريقة الستاتيكية لانوفا (التحاليل التباين) وهي ... more في هذه الورقة قمنا باستعمال طريقتين رياضيتين : الطريقة الستاتيكية لانوفا (التحاليل التباين) وهي الطريقة القديمة والمأخوذ فكرتها من برنامج spm والطريقة الجديدة المقترحة من طرفنا وهي SOR وأسلوب التكرار التي تقوم على فحص سطح الصورة واكتشاف الاورام بدقة وسرعة كبيرة مقارنة مع انوفا, البرنامج المطبق هنا هو الماتلاب
International Journal of Engineering & Technology
This paper deals with real time surface detection for image processing and analysis. We propose a... more This paper deals with real time surface detection for image processing and analysis. We propose an appropriate analysis method with analysis of variance two ways to detect all surfaces of images in accuracy time. The results indicate that Anova_2 converged to the solution in accuracy time in comparison with Anova_1 for linear model.
International Journal of Electronics and Electrical Engineering
In this paper iterative method is proposed with Gauss Seidal (G.S) to detect the position of dise... more In this paper iterative method is proposed with Gauss Seidal (G.S) to detect the position of disease on MR image with less computation time than the statistical approach (student's t test). To solve linear systems, Gauss Seidal build a sequence of approximations that converges to the true solution on other side Student method adjusts a least square model by statistical estimating. Our results obtained with G.S are excellent with accuracy time in front of Student method. The images are obtained from radiology of KOUBA Hospital of Algeria. The software used here is Matlab.
Courrier Du Savoir, 2010
L'objectif principal de notre travail est de faire un ajustement linéaire de la technique BOLD (B... more L'objectif principal de notre travail est de faire un ajustement linéaire de la technique BOLD (Blood Oxygenation Level Dependent) de l'IRMf. Ce qui permet de mieux étudier et explorer cette technique. Celle ci comporte une réponse hémodynamique (hrf) dont la forme a été choisie par Friston & Al en 1994[1] et qui dépend du taux d'oxygène dans le sang, du débit et du volume sanguin .Pour cette raison on a appliqué une technique mathématique d'ajustement sur la base du modèle linéaire;qui contient le bus de données des trames d'image (la série temporelle) , la matrice expérimentale , la régression ou bien les paramètres voulus de l'estimation et Finalement l'erreur du calcul qui doit être minimale. D'après le modèle linéaire et l'application de t-test Student on trouve une activité inférieure a 0.05. Ceci est visualisé sur une glass de Talairach.
Courrier Du Savoir, 2010
L'objectif principal de notre travail est de faire un ajustement linéaire de la technique BOLD (B... more L'objectif principal de notre travail est de faire un ajustement linéaire de la technique BOLD (Blood Oxygenation Level Dependent) de l'IRMf. Ce qui permet de mieux étudier et explorer cette technique. Celle ci comporte une réponse hémodynamique (hrf) dont la forme a été choisie par Friston & Al en 1994[1] et qui dépend du taux d'oxygène dans le sang, du débit et du volume sanguin .Pour cette raison on a appliqué une technique mathématique d'ajustement sur la base du modèle linéaire;qui contient le bus de données des trames d'image (la série temporelle) , la matrice expérimentale , la régression ou bien les paramètres voulus de l'estimation et Finalement l'erreur du calcul qui doit être minimale. D'après le modèle linéaire et l'application de t-test Student on trouve une activité inférieure a 0.05. Ceci est visualisé sur une glass de Talairach.
Uploads
Papers by kaouther el kourd