International Conference on Instrumentation, Communication, Information Technology, and Biomedical Engineering 2009, 2009
This paper explains the influence of the tape-core layer number to the demagnetization factor of ... more This paper explains the influence of the tape-core layer number to the demagnetization factor of a fluxgate sensor. The demagnetization factor was calculated based on the physical dimension, the self-inductance of coil without inserting the core ( _ no core L ) and by inserting the core ( core L ) of the sensor. The calculated demagnetization factor to pick-up coil configurations of 2x80 are proportional, 0.51, 0.82, 1.15, and 1.40 x10 -3 whereas the one to pick-up coil configurations of 2x20 are 1.02, 1.58, 2.23, and 2.78x10 -3 , each of which uses the tape-core layer number 1,2, 3, and 4 respectively.