HiveBoard Logo HiveBoard: An Open, Modular, 3D-Printed Benchmark of Industrial Mechanisms for Robotic and Prosthetic Manipulation

Ricardo V. Godoy1, Enzo F. de Souza1, Matheus P. Angarola1, Juliano Negri1, João H. Aléssio1, Victor van Halst1, Giuseppe Milazzo2, Gianluca Capezzuto1, Felipe Tommaselli1, Francisco Affonso3, João A. Marsicano1, Rudy De-Xin de Lange4, Aravind Elanjimattathil Vijayan5, Amy M. Ramírez Sánchez6, Shifei Duan7, Rafael R. Baptista8, Girish Chowdhary3, Ranulfo Bezerra9, Gustavo J. G. Lahr10, Lucas Ferrari Gerez4, Antonio Bicchi2, Marcelo Becker1
1Mobile Robotics Group, University of São Paulo, Brazil
2Soft Robotics for Human Cooperation and Rehabilitation, Istituto Italiano di Tecnologia, Genoa, Italy
3University of Illinois Urbana-Champaign, USA
4ARARA Lab, James Watt School of Engineering, University of Glasgow, Scotland, UK
5The Robotics Systems Lab ETH Zurich, Zurich, Switzerland
6Directorate of Technological Innovation, Universidad de las Américas Puebla, Mexico
7New Dexterity research group, The University of Auckland, New Zealand
8Biomedical Engineering Laboratory, University of São Paulo, Brazil
9Graduate School of Engineering, Tohoku University, Sendai, Japan
10Faculdade Israelita de Ensino e Pesquisa Albert Einstein, Hospital Israelita Albert Einstein, São Paulo, Brazil
Corresponding author:
HiveBoard
HiveBoard
HiveBoard

Abstract

Manipulation is mostly benchmarked on free objects, through grasping, pick-and-place, and assembly of loose parts. The mechanisms that make manipulation useful in the world are not free objects: a valve resists rotation, a screw advances only along its thread, a lock opens only after a key is inserted and turned. Performance on such constrained, force-dependent, often multi-step devices is poorly predicted by grasping scores, and the physical benchmarks that do cover mechanisms are built from purchased components, which makes them hard to reproduce or modify. We present HiveBoard, an open, modular, and accessible, fully 3D-printed benchmark that lets any laboratory evaluate grippers, hands, and manipulation policies on functional mechanisms. A hexagonal honeycomb base accepts 12 interchangeable attachment designs modeled on industrial fittings and grouped into three skill categories — torque, precision, and composed assembly — all fully functional, printable on consumer-grade FDM printers, and released with articulated URDF and USD models for direct import into common simulators. A cross-laboratory validation of six systems spans quadruped and mobile manipulators, fixed-base arms, a VR-driven legged manipulator, and a wearable prosthetic hand. Each system completed 65 trials across 13 conditions, including the ball valve with and without its friction ring. Only the ring-fitted ball valve succeeded in every trial on all six platforms; none completed peg insertion. Difficulty-ordering correlations range from 0.20 to 0.88, and the failure causes reveal different limits across the systems.

HiveBoard with eight surrounding robot platforms
Validation Hand
Validated with: Macao wearable anthropomorphic prosthetic hand, worn on the operator's forearm (Platform D)
Validation s010
Validated with: LeRobot SO-101 fixed-base arm under leader-follower teleoperation (Platform B)
Validation Quadruped
Validated with: Boston Dynamics Spot with the Spot Arm, teleoperated from the native tablet interface (Platform A)
Validation ANYmal
Validated with: ANYbotics ANYmal with a DynaArm and a Robotiq 2F-140 gripper, commanded through a Meta Quest 3 (Platform C)
Franka Research 3 robotic arm
Validated with: Franka Research 3 with a parallel-jaw gripper (Platform E)
Alter-Ego mobile manipulator with a five-finger hand
Validated with: Alter-Ego mobile manipulator with a Pisa/IIT SoftHand (Platform F)
UR20 arm with a Robotiq 2F-140 gripper
Validated with: UR20 with a Robotiq 2F-140 gripper (Platform H)
Prosthetic User with SoftHand Pro
Validated with: Prosthetic User with SoftHand Pro (Platform G)

Torque-based tasks

A ball valve, two gate valves, and a circuit breaker. A four-piece snap-on friction ring set modulates the breakaway torque of the ball valve without printing a second one.

Precision-based tasks

A light bulb socket, M8 and M30 threaded fasteners, and a peg-insertion plate with 8 mm threaded pins that demand tight-clearance alignment followed by sustained axial rotation.

Composed assembly

A covered push button, a key-and-lock mechanism, a sliding drawer, and a two-cell shock absorber. Each requires several sub-actions and is scored stage by stage, so partial competence is visible in the data.

Interactive 3D Benchmark

Explore the HiveBoard interactively in 3D. The base is a seven-cell hexagonal honeycomb in which every cell is an open frame that accepts an attachment through a shared press-fit interface, with no fasteners required. Rotate the perspective, snap attachments into free cells, and compose the evaluation scene you intend to print, in the large, medium, or small board version.

Interactive 3D Benchmark Explorer

Click to interact with the modular boards and tasks

Attachments & Specifications

The library contains 12 attachment designs evaluated in 13 conditions across three task categories. Select a category below to compare each printed part with its digital twin and review the success criterion, timeout, and stage decomposition used by the evaluation protocol.

Optional hardware includes ArUco cells with IDs 0 and 1 for board localization and a 360° ball-valve variant for training and controller debugging. The variant allows rotation beyond the quarter-turn target to reduce damage from overshoot. The benchmark Ball valve task remains a 90° rotation.

3D Model
Real Object
Real Object 3D Model

Loading...

Parameter Value

Simulation Compatibility

Every attachment and the base are released as articulated CAD assets, organized per assembly with URDF descriptions, USD exports, and OBJ visual and collision meshes, so the same task can be run physically or in simulation.

Newton

GPU-accelerated physics engine for robotics. HiveBoard’s URDF and USD assets can be used as the starting point for Newton scenes.

Test

Isaac Lab

HiveBoard environments for Spot, Franka FR3, and ANYmal, running with Newton MJWarp.

Test

Isaac Sim

USD assets for HiveBoard assemblies and the honeycomb base are available for composing and simulating scenes.

ManiSkill

Robotics simulation and learning framework powered by SAPIEN. Use the released URDF and mesh assets to build custom HiveBoard task environments.

Test

Try it in the browser

Still under development

MuJoCo compiled to WebAssembly — real physics, no install

Pick a platform and a task, and the arm runs a fixed trajectory for it against a seven-cell board, the swappable centre cell holding whichever attachment the task calls for. These are demonstrations, not benchmark runs — they do not follow the evaluation protocol. Robot models from mujoco_menagerie (Apache-2.0); interactive simulator interface based on Tune to Learn; board and attachments built from the URDF release above.

Video Demonstrations

Recorded trials from the cross-laboratory validation. Each laboratory printed the board from the released files and ran the same protocol on its own hardware, so a single attachment can be compared across a quadruped-mounted gripper, a legged manipulator, tabletop arms, the Alter-Ego mobile manipulator, and a prosthetic hand worn on an operator’s forearm.

Results

Each laboratory prints the board from the released files and runs the same protocol on its own hardware: five recorded trials per condition, a fixed neutral start pose, task-specific timeouts, no scripted assistance. Select any cell, platform, or condition to see what happened in those trials.

5/5 completed partial (1–4/5) 0/5 — no success

Success rates carry 95% Wilson confidence intervals over N = 5 trials per cell. The intervals are wide by design: this is a per-laboratory reproducibility check, not a high-resolution ranking. Each platform was operated by a single operator at a single laboratory, so operator skill and platform capability are not separable in these data.

Same seven, same six

A tablet-teleoperated quadruped arm and a VR-driven legged manipulator share no arm, gripper, or interface, yet complete an identical set of seven conditions and fail on the same six — for entirely different logged reasons.

Assembly tasks separate the platforms

The Spot Arm and ANYmal failed both the drawer and shock absorber in every trial. The SO-101 and Macao, SoftHand Pro, and UR20 completed both; the FR3 completed the shock absorber, and Alter-Ego completed one drawer trial.

Two new platform results

SoftHand Pro completed 60/65 trials, including both threaded fasteners. The UR20 completed 50/65 and was the only platform to complete peg insertion (2/5).

Cross-platform analysis

Each platform ranks the 13 conditions by unsuccessful trials first and normalized median time second, and the eight orderings are then compared pairwise with a Spearman correlation. A high correlation means the board is measuring properties of the tasks rather than idiosyncrasies of one system.

Mean, all 28 pairs 0.67

range 0.20 to 0.89

Spot Arm ↔ ANYmal 0.84

the two legged bases

Alter-Ego ↔ SoftHand Pro 0.89

highest pair in the study

Alter-Ego ↔ SO-101 0.20

lowest pair in the study

SoftHand Pro correlates most with Alter-Ego (0.89), while the UR20 correlates most with the FR3 (0.80). The lowest pair is Alter-Ego and SO-101 (0.20).

HiveScore

Success weighted by completion speed relative to the unimpaired human reference.

Human reference: 85.8–97.8
PlatformSuccessesConditionsMedian slowdownHiveScore
A · Spot Arm35/6579.8× (6.6–12.8)5.8 (5.4–6.1)
B · SO-10144/6595.8× (3.8–19.3)12.0 (11.3–12.6)
C · ANYmal35/6576.1× (4.6–10.1)8.7 (8.2–9.2)
D · Macao hand53/65111.6× (0.9–14.7)41.6 (40.0–43.2)
E · FR340/65910.9× (8.3–19.1)5.7 (5.4–6.0)
F · Alter-Ego34/65916.6× (6.0–28.7)3.7 (3.5–3.9)
G · Prosthetic User with SoftHand Pro60/65121.6× (0.9–11.7)51.1 (50.5–52.3)
H · UR2050/65127.6× (4.6–20.9)9.7 (9.6–10.0)

13

Evaluation conditions across 12 attachment designs in three task categories

520

Recorded trials, 65 on each of the eight platforms, under one fixed protocol

1.6–103 s

Span of median completion times, from the circuit breaker to the M30 thread

0

Purchased parts, metal inserts, or post-machining steps needed to reproduce the board

Data Collection API

To standardize manipulation data collection across laboratories and robotic platforms, we created DataHive — a dedicated API and client toolkit designed to collect, validate, annotate, and record HiveBoard manipulation episodes.

Recorded data October 2026
Real robot 2.5 hours 447 episodes
Simulation 25.9 hours 1,950 episodes

DataHive & datahive-tools

What it's for: Provides a streamlined pipeline to record robot trials, validate episode integrity (verifying timestamps, frequencies, and synchronized multi-camera MP4 streams), annotate outcomes in a local web interface, and upload structured datasets directly to our official repository on the Hugging Face Hub (HiveBoard/<lab_id>).

Contributing data: All contributions go directly into our central repository. Register your laboratory using the registration form to receive your designated Lab ID and Hugging Face Token, allowing DataHive to authenticate and upload directly to HiveBoard/<lab_id>. See our Open Calls for full dataset requirements and authorship eligibility.

Reference integration: Looking for a starting point? See the fr3_datahive repository for a Dockerized Franka Research 3 (FR3) setup with ROS and joystick teleoperation.

Installation

pip install datahive-tools

Installs the datahive CLI and Python CollectClient for recording, validating, and managing datasets.

Official HiveBoard Repository

Submit the registration form to receive your unique Lab ID and Hugging Face Token. All uploads go directly to our official repository on the Hub (HiveBoard/<lab_id>).

Open Calls for Contributions

We invite laboratories, individual researchers, and teams to contribute manipulation datasets using HiveBoard or develop functional attachments for two benchmark extensions. Accepted contributions may establish eligibility for co-authorship on future papers.

Dataset Call

Learning Datasets

Demonstrations and robot rollouts with synchronized states, actions, camera streams, and task outcomes for imitation and visuomotor policy learning. No fixed episode count or 13-condition requirement.

Hardware Call

Daily Living (ADL)

Functional mechanisms representing everyday manipulation tasks (container lids, latches, dispensers, household controls). Must feature repeatable initial states and observable success criteria.

Hardware Call

Bimanual Tasks

Functional attachments requiring coordinated two-hand manipulation (e.g. holding while turning, maintaining spring tension during insertion, aligning movable components).

Authorship & Submission Process

Substantial accepted datasets and complete functional attachments (CAD, printables, simulation model, task definition, and validation) establish eligibility for co-authorship on future benchmark papers. Contact the team before starting fabrication or collection.

Citation

@article{hiveboard2026,
  title   = {HiveBoard: An Open, Modular, 3D-Printed Benchmark of Industrial Mechanisms
             for Robotic and Prosthetic Manipulation},
  author  = {Godoy, Ricardo V. and
             de Souza, Enzo F. and
             Angarola, Matheus P. and
             Negri, Juliano and
             Aléssio, João H. and
             van Halst, Victor and
             Milazzo, Giuseppe and
             Capezzuto, Gianluca and
             Tommaselli, Felipe and
             Affonso, Francisco and
             Marsicano, Jo\~{a}o A. and
             de Lange, Rudy De-Xin and
             Elanjimattathil Vijayan, Aravind and
             Ramírez Sánchez, Amy M. and
             Duan, Shifei and
             Baptista, Rafael R. and
             Chowdhary, Girish and
             Bezerra, Ranulfo and
             Lahr, Gustavo J. G. and
             Ferrari Gerez, Lucas and
             Bicchi, Antonio and
             Becker, Marcelo},
  journal = {Under review},
  year    = {2026},
  url     = {https://github.com/hiveboard-bench/HiveBoard}
}

Acknowledgments

HiveBoard, the CAD library, the evaluation protocol, and the logging templates are released under a permissive license at github.com/hiveboard-bench/HiveBoard. We thank the collaborating laboratories that printed the board locally and ran the protocol on their own manipulation systems for the cross-laboratory validation reported here, and Luiz Felipe Rodrigues Dantas for assistance in validating the simulated assets. We thank Meiko A. van Berge for assistance with data collection.

This work was supported by the São Paulo Research Foundation (FAPESP), Grants #2025/08520-0, #2025/22381-3, #2025/20858-7, and #2025/04308-7; by Petróleo Brasileiro S/A — Petrobras, using resources from the ANP R&D clause, in partnership with the University of São Paulo (USP) and the Fundação de Apoio à Física e à Química (FAFQ), under Cooperation Agreements #2023/00016-6 and #2023/00013-7; by ANYbotics AG; and by the Royal Society Research Grant (grant number 251405).

University of São Paulo ETH Zürich University of Glasgow Istituto Italiano di Tecnologia Albert Einstein Hospital Tohoku University University of Auckland
Mobile Robotics Lab Robotic Systems Lab Arara STEM UDLAP University of Illinois Urbana-Champaign

HiveBoard Interactive 3D

Add, rotate and interact with the project pieces

Board Size

Select a task or optional ArUco cell below to add it to an available slot on the honeycomb board.

Torque-based tasks

Precision-based tasks

Composed assembly tasks

Localization