The server connection loop (RemoteControlServer.HandleConnectionAsync) only exits when ReceiveAsync returns null/throws. There is no server-side WebSocket keepalive (app.UseWebSockets() is configured without KeepAliveInterval). Keep-alive/ping messages exist in the protocol, but the server side does not use them to detect a dead peer.
Consequence: if an app dies without a clean TCP close (hard crash, network drop, or a client reconnect that abandons the old socket), the old /rc connection stays "open" server-side → its workspace + DebuggingSession (~500 MB) linger indefinitely, coexisting with the new connection's workspace. Measured: two concurrent connections = two workspaces (~1.35 GB), zero Disposing connection.
Proposal: enable server-side WebSocket keepalive with a timeout (or an application-level ping deadline using the existing KeepAlive messages), and dispose the connection scope (→ EndSession + workspace dispose) when a peer stops responding. This reaps orphaned workspaces with no active kill and no risk of a reconnect storm.
Verified on Uno.WinUI.DevServer 6.8.0-dev.159 (Uno.Sdk 6.8.0-dev.39), Windows, net10.0-desktop. Partially
fixed — the keepalive lands, the workspace reclaim does not.
Fixed:RemoteControlServer.HandleConnectionAsync now bounds every receive with receiveCts.CancelAfter(keepAliveTimeout), where ResolveKeepAliveTimeout() = uno-devserver:keep-alive-timeout-ms
if set, else KeepAliveMessage.Interval (30s) × 2.1 = 63 s.
Tested against a real half-open socket (NtSuspendProcess on a connected app — TCP stays established, client stops
pinging):
default: connection closed 63 s after the last ping (lifetime 94.6 s), then Disposing connection + Unloading assembly context UnoApp1
--uno-devserver:keep-alive-timeout-ms=15000: lifetime drops to 17–20 s
Deadline is causal, config knob works, and the "zero Disposing connection" symptom is gone.
Not fixed: the ticket also expects the scope disposal to give "EndSession + workspace dispose" and to "reap
orphaned workspaces". EndSession happens; the workspace dispose doesn't. gcroot on a dump taken right after the
reap (single app, single workspace):
type
instances
rooted
EditAndContinue.DebuggingSession
1
0 roots ✅
MSBuild.MSBuildWorkspace
1
still rooted ❌
ServerHotReloadProcessor
1
still rooted
Uno.HotReload.HotReloadManager
1
still rooted
Host RSS stayed at 565 MB. (RSS alone proves nothing here — the host runs workstation GC with HeapHardLimitPercent: 66, so nothing decommits on an idle machine; hence gcroot.)
Activity
fix(devserver): close presumed-dead /rc connections via server-side k…
khaskoul commentedon Sep 14, 2026
Verified on
Uno.WinUI.DevServer6.8.0-dev.159 (Uno.Sdk 6.8.0-dev.39), Windows,net10.0-desktop. Partiallyfixed — the keepalive lands, the workspace reclaim does not.
Fixed:
RemoteControlServer.HandleConnectionAsyncnow bounds every receive withreceiveCts.CancelAfter(keepAliveTimeout), whereResolveKeepAliveTimeout()=uno-devserver:keep-alive-timeout-msif set, else
KeepAliveMessage.Interval (30s) × 2.1= 63 s.Tested against a real half-open socket (
NtSuspendProcesson a connected app — TCP stays established, client stopspinging):
Disposing connection+Unloading assembly context UnoApp1--uno-devserver:keep-alive-timeout-ms=15000: lifetime drops to 17–20 sDeadline is causal, config knob works, and the "zero
Disposing connection" symptom is gone.Not fixed: the ticket also expects the scope disposal to give "
EndSession+ workspace dispose" and to "reaporphaned workspaces".
EndSessionhappens; the workspace dispose doesn't.gcrooton a dump taken right after thereap (single app, single workspace):
EditAndContinue.DebuggingSessionMSBuild.MSBuildWorkspaceServerHotReloadProcessorUno.HotReload.HotReloadManagerHost RSS stayed at 565 MB. (RSS alone proves nothing here — the host runs workstation GC with
HeapHardLimitPercent: 66, so nothing decommits on an idle machine; hencegcroot.)Two causes:
ServerHotReloadProcessor.Dispose()cancels but never drops the reference —_workspace?.Ct.Cancel();with no_workspace = null. CompareDisableHotReloadAsync(the fix(devserver): cap concurrent hot-reload workspaces, disable oldest without closing the socket #24240 cap path), which does null it, and whose workspaces Imeasured as genuinely unrooted.
AssemblyLoadContext (held by Roslyn MEF DefaultAnalyzerService -> AnalyzerAssemblyLoader)
-> Func<ALC, AssemblyName, Assembly> (Resolving handler, never unsubscribed)
-> DefaultRemoteControlProcessorFactory
-> ServiceProviderEngineScope (the "disposed" connection scope)
-> RemoteControlServer -> ServerHotReloadProcessor -> HotReloadManager -> MSBuildWorkspace
Jen-Uno commentedon Sep 30, 2026
QA: closing out without a manual pass. The fix in #24213 ships with automated tests (