You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
{{ message }}
Repository navigation
Numerical Exploration of $C_{10c}$ bounds via SDP Relaxations (CVXPY) #67
I've been looking at the discrepancy bounds in the repository, specifically the unverified upper bound of $3.65^*$ for $C_{10c}$ (Spencer's constant). To explore the worst-case behavior numerically, I modeled a Bansal-style Semidefinite Relaxation (SDR) using CVXPY and the SCS solver for $n=512$.
Empirical Findings ($n=512$):
Structured Systems: For a $512 \times 512$ subset of a Hadamard matrix, the SDR yields a tight lower bound of exactly $0.5\sqrt{n}$.
Unstructured Systems: For a $512 \times 512$ random Bernoulli matrix ($p=0.5$), the SDR yields a highly relaxed bound of $\approx 0.027\sqrt{n}$.
Discussion:
These numerical results cleanly illustrate the theoretical expectation: random instances are "soft" in the SDR, while structured orthogonality (Hadamard) raises the bound. However, both fall vastly short of the $3.67$ universal constant. This suggests that any computational effort to strictly verify or tighten the $3.65^*$ bound using relaxations will require generating highly correlated, adversarial non-orthogonal incidence matrices.
If the maintainers are interested, I would be happy to submit a PR adding this CVXPY formulation to a /scripts directory so others can easily benchmark specific adversarial set systems against these relaxations.
I ran a reproducible CVXPY/SCS baseline for C_10c and checked the existing 17x17 certificate. The certificate has exact discrepancy 7, giving 7/sqrt(17)=1.697749375254. For the vector/Gram SDP relaxation on that same matrix I obtain SDP value 3.741657247 and normalized 0.907485179. I also tested random, Hadamard, local-search, annealing, Kronecker-lift, and block-perturbation 8x8 candidates; none yielded a certified improvement. The scripts and logs are available at https://github.com/whyihaveyou/c10c-experiments. These are screening results only; any new lower bound still needs exhaustive verification and an explicit certificate.
Activity
whyihaveyou commentedon Sep 6, 2026
I ran a reproducible CVXPY/SCS baseline for C_10c and checked the existing 17x17 certificate. The certificate has exact discrepancy 7, giving 7/sqrt(17)=1.697749375254. For the vector/Gram SDP relaxation on that same matrix I obtain SDP value 3.741657247 and normalized 0.907485179. I also tested random, Hadamard, local-search, annealing, Kronecker-lift, and block-perturbation 8x8 candidates; none yielded a certified improvement. The scripts and logs are available at https://github.com/whyihaveyou/c10c-experiments. These are screening results only; any new lower bound still needs exhaustive verification and an explicit certificate.