You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
I thought every inferential statistic uses now use_t. However, while cleaning up the docs I saw that LikelihoodModelResults.conf_int has normal distribution hardcoded.
I thought I have generic tests for this. But maybe only for the defaults.
relevant PR is #1189
It didn't change conf_int which is a mistake, but it has unit tests for conf_int. So I guess there is no test case with non-default conf_int.
linear_model.RegressionResults.conf_int uses use_t
code comment: should be obsolete except super LikelihoodModelResults.conf_int doesn't use use_t
reading through the comments in PR1189, I see it was only/mainly for regression, not for all models.
need another round of refactoring to make the missing changes in base and other models.
Activity
josef-pkt commentedon Jul 8, 2014
GEEResultsalso defines its ownconf_inthardcoded for normal distributionENH: add use_t to LikelihoodModelResults pvalues and confint closes s…
ENH: add use_t to LikelihoodModelResults pvalues and confint closes s…