Repository navigation
JCL oracle tier 2: GDG relative generations probed on MVS 3.8J, 18 of 20 agree, 2 box findings (Part of #8414) - #8832
Merged
Conversation
… 20 agree, 2 box findings (Part of #8414) probe.py gdg defines a GDG base per scenario (IDCAMS DEFINE GDG + model DSCB, IEHPROGM scratch), runs (+1)/(0)/(-1) in one job and reads IEF237I/IEF285I/IEF287I and LISTCAT. GDGBIAS (6) and restart (5) scenarios are skipped and listed. Two disagreements are register findings. Co-Authored-By: Claude Sonnet 5.5 <[email protected]>
Contributor
|
No description provided. |
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
Part of #8414
What
The GDG relative-generation slice of the JCL tier-2 oracle (MVS 3.8J on Hercules, internal only, Q16).
probe.py gdgdefines a GDG base per scenario with IDCAMSDEFINE GDGplus a model DSCB and IEHPROGM, runs the scenario's(0)/(+1)/(-1)DDs as one job, and reads the allocation messages andLISTCATafterwards. Results:tests/equivalence/jcl/gdg/mvs38j_probe.json(provenancemvs38j-run, three columns: manualexpect,engine,box).Run 2026-11-20 on the live box: 20 scenarios run, 18 agree three ways, 2 differ on the box. Skipped and listed in the file: 6 GDGBIAS scenarios (a z/OS JOB keyword) and 5 restart scenarios (later slice).
Findings (register entries;
expectand the evaluator are untouched)empty-rolls-off-every-generation-at-limit: with EMPTY at the limit, the(+1)in the first step uncatalogs the old generations at that step, so a later step's(0)failsIEF212I DATA SET NOT FOUNDand the step does not run. The catalog afterwards agrees.new-keep-is-a-deferred-roll-in: a(+1)madeDISP=(NEW,KEEP)is not cataloged, so a later step's(+1) DISP=SHRisIEF286I DISP FIELD INCOMPATIBLE WITH DSNAME, a JCL error. The catalog afterwards agrees.Also solved: the
IEF218I PATTERN DSCBfailure recorded by the data-flow probe (the model DSCB and every generation must sit on the volume the group is pinned to).docs/jcl_oracle_mvs38j.mdcarries the new section and the box traps.Class / Sibling gaps
Class: a tier-2 probe slice per answer-set family, three columns per scenario. Siblings: GDGBIAS (6) and restart (5) scenarios in the same file are not run; SYSOUT class (
SYSJOB), IEBGENER / IEBCOPY / IEFBR14 dataset scenarios andcarddemoare untouched. The register entries for the two findings are not filed as issues here.Remaining slices
SYSOUT class, IEBGENER / IEBCOPY / IEFBR14 dataset scenarios, restart (incl. the 5 skipped GDG restart scenarios),
carddemowhere 3.8J has the construct. IF / THEN / ELSE, GDGBIAS and system-managed GDGs cannot run on 3.8J.Checklist: partial [c:f8795ef7] -- remaining: SYSOUT class, dataset utilities, restart, carddemo
Gates
ruff format --checkandruff checkonprobe.py; ruff / mypy / dead-key / doc-refs--ciaudits (no new findings);tests/tools/test_mvs38j_probe.py,tests/cobol_mainframe/test_jcl_gdg_case.pyand the capability-ledger tests pass.pr_gates --fast(and the bundledaudit_check) sat queued behind other workers on the heavy slots for over 40 minutes and had not run when this PR opened; CI will. No parsing logic touched, so no golden bless.Lessons for agents
IEF287I ... NOT RECTLGDis a disposition line (a MOD,CATLG on an already-cataloged generation); a parser that reads onlyIEF285Iloses the step.IEF237Iper generation andUNCATALOGED/DELETEDpairs per generation: merge them before aligning DDs to datasets.VOL=SER=PUB001); IEHPROGM / IEHLIST takeVOL=3390=PUB001.🤖 Generated with Claude Code