Skip to content

det/CICS: data-value options take a constant across commands (Part of #8058) - #8066

Merged
squid-shepherd[bot] merged 3 commits into
mainfrom
fix/8058-cics-data-values
Nov 8, 2026
Merged

squid-shepherd[bot] merged 3 commits into
mainfrom
fix/8058-cics-data-values

Conversation

@squid-protocol

Copy link
Copy Markdown
Owner

Part of #8058. Builds on #8057 (WEB CONVERSE SESSTOKEN / URIMAP, Part of #7959). #8057 has merged, and main is merged into this branch, so the diff is this PR's change only.

What

An option IBM declares a data-value (a sender; IBM "COBOL argument values": "For a data-value, you can also use a constant") was read by det through the data-area path (Cics.ref / field / read_field), so a literal was refused as not a data area ... source defect, #7959. That refusal, owned by gap_prevalence.OWNERS as a source defect, is only right where IBM declares a data-area.

  • New Cics.value_text (det/cics.py): a data name keeps Cobol.text(<read_field>, CS), byte-identical to before; a literal (alphanumeric, hex, numeric) is its value (gen.text); a figurative constant is refused by name (figurative constant as a data-value ... not modelled, #8058): it has no length of its own and the length CICS's translator gives it is not modelled. That refusal is an open translator gap, not a source defect.
  • det/CICS WEB CONVERSE: SESSTOKEN and URIMAP take a constant, as IBM's data-values do (Part of #7959) #8057's WEB CONVERSE value() now calls it (same output).
  • 10 more options switched to it (table). Data-area options stay strict.

Audit table

Every ref / field / read_field call site in det/cics*.py. Receivers (CICS writes the operand) are data-areas by definition and IBM's diagrams agree on every one fetched; they are grouped. IBM types are from the CICS TS 6.x syntax diagrams (https://www.ibm.com/docs/en/cics-ts/6.x?topic=summary-<command>).

Command Option IBM type det before det after URL
WEB CONVERSE SESSTOKEN, URIMAP data-value (fixed in #8057) value_text ?topic=summary-web-converse
WEB CONVERSE PATH, QUERYSTRING, FROM, MEDIATYPE, STATUSTEXT, INTO data-area read_field / field unchanged ?topic=summary-web-converse
WEB CLOSE SESSTOKEN data-value read_field value_text ?topic=summary-web-close
WEB OPEN HOST data-value read_field value_text ?topic=summary-web-open
WEB OPEN SESSTOKEN (receiver) data-area field unchanged ?topic=summary-web-open
WEB SEND (server) DOCTOKEN data-value read_field value_text ?topic=summary-web-send-server
WEB SEND MEDIATYPE data-value quoted literal only (#6876), else read_field quoted literal path unchanged; else value_text ?topic=summary-web-send-server
WEB SEND FROM, STATUSTEXT data-area read_field unchanged ?topic=summary-web-send-server
WEB PARSE URL URL data-value read_field value_text ?topic=summary-web-parse-url
WEB PARSE URL SCHEMENAME, HOST, HOSTLENGTH, PATH, PATHLENGTH, QUERYSTRING, QUERYSTRLEN, PORTNUMBER (receivers) data-area field / ref unchanged ?topic=summary-web-parse-url
WEB WRITE HTTPHEADER SESSTOKEN data-value read_field value_text ?topic=summary-web-write-httpheader
WEB WRITE HTTPHEADER HTTPHEADER, VALUE data-area (diagram and option text) literal accepted (#6876 htext) unchanged (see Sibling gaps) ?topic=summary-web-write-httpheader
WEB READ HTTPHEADER HTTPHEADER data-area literal accepted (htext) unchanged (see Sibling gaps) ?topic=summary-web-read-httpheader
WEB READ HTTPHEADER VALUE, VALUELENGTH (receivers) data-area field / ref unchanged ?topic=summary-web-read-httpheader
WEB READ QUERYPARM QUERYPARM data-value read_field value_text ?topic=summary-web-read-queryparm
WEB READ FORMFIELD FORMFIELD data-area read_field unchanged ?topic=summary-web-read-formfield
WEB STARTBROWSE FORMFIELD / QUERYPARM FORMFIELD, QUERYPARM data-area read_field unchanged ?topic=summary-web-startbrowse-formfield, ?topic=summary-web-startbrowse-queryparm
WEB READNEXT, WEB EXTRACT, WEB RECEIVE, WEB RETRIEVE, EXTRACT TCPIP every operand det reads through field / ref (receivers) data-area field / ref unchanged receivers (pages not fetched)
DOCUMENT CREATE TEXT, BINARY data-area read_field unchanged ?topic=summary-document-create
DOCUMENT CREATE DOCTOKEN (receiver) data-area field unchanged ?topic=summary-document-create
DOCUMENT RETRIEVE DOCTOKEN data-area read_field unchanged ?topic=summary-document-retrieve
DOCUMENT RETRIEVE INTO, LENGTH (receivers) data-area field / ref unchanged ?topic=summary-document-retrieve
WRITE OPERATOR TEXT, ROUTECODES data-value read_field value_text ?topic=summary-write-operator
VERIFY PASSWORD USERID data-value read_field value_text ?topic=summary-verify-password
GETMAIN INITIMG data-value, but "In COBOL programs only, you must use a data area rather than a data value" literal refused unchanged (IBM's COBOL rule) ?topic=summary-getmain
PUT CONTAINER FROM data-area read_field unchanged ?topic=summary-put-container-channel
GET CONTAINER / GETNEXT CONTAINER INTO, FLENGTH, CCSID, CONTAINER (receivers) data-area field / ref unchanged receivers
WRITEQ TS / WRITEQ TD FROM data-area read_field unchanged ?topic=summary-writeq-ts, ?topic=summary-writeq-td
READQ TS / READQ TD INTO, LENGTH, ITEM, NUMITEMS (receivers) data-area field / ref unchanged receivers
START FROM data-area read_field unchanged ?topic=summary-start
CONVERSE FROM data-area read_field / ref unchanged ?topic=summary-converse-default
CONVERSE INTO, TOLENGTH (receivers) data-area field / ref unchanged ?topic=summary-converse-default
SEND MAP FROM data-area ref unchanged ?topic=summary-send-map
SEND (terminal) FROM unverified (page did not load) read_field / ref unchanged ?topic=summary-send-default
RECEIVE / RECEIVE MAP INTO, LENGTH (receivers) data-area field / ref unchanged receivers
READ / READNEXT / READPREV RIDFLD data-area field unchanged ?topic=summary-read
READ INTO, LENGTH, TOKEN (receivers) data-area field / ref unchanged ?topic=summary-read
WRITE FROM, RIDFLD data-area read_field / field unchanged ?topic=summary-write
REWRITE FROM data-area read_field unchanged ?topic=summary-rewrite
DELETE RIDFLD data-area field unchanged ?topic=summary-delete
STARTBR / RESETBR RIDFLD data-area field unchanged ?topic=summary-startbr
LINK / XCTL / RETURN COMMAREA data-area ref unchanged ?topic=summary-link, ?topic=summary-xctl, ?topic=summary-return
FORMATTIME ABSTIME data-area field unchanged ?topic=summary-formattime
FORMATTIME / ASKTIME the date / time forms, ABSTIME (receivers) data-area field / ref unchanged ?topic=summary-formattime
BIF DEEDIT FIELD (read and written) data-area field unchanged ?topic=summary-bif-deedit
ASSIGN, INQUIRE ASSOCIATION / URIMAP / PROGRAM, RESP / RESP2, GET / DEFINE COUNTER, FETCH, RUN TRANSID, RETRIEVE, WAIT / POST, GETMAIN / FREEMAIN every operand det reads through field / ref (receivers) data-area field / ref unchanged receivers
GET / UPDATE COUNTER VALUE, INCREMENT, COMPAREMIN / COMPAREMAX (senders) n/a here _clong / _cint: ref only for a raw data area, else long_ / int_ (constants already accepted) unchanged not a data-area path

Counts: about 49 call sites; 48 sender (command, option) positions checked against IBM's 6.x pages, the rest receivers. 12 data-value options were read as data-areas: 2 fixed in #8057, 10 (in 8 commands) fixed here; 1 unverified (SEND FROM, left strict); GETMAIN INITIMG is a data-value IBM requires as a data area in COBOL (left strict).

Class / Sibling gaps

Class: an EXEC CICS option IBM declares a data-value, read by det as a data-area, so valid IBM source was refused as a "source defect". Every member found in det/cics*.py is handled in this PR or #8057 (table above). Sibling gaps, not done here:

Remaining slices

  • tests/tools/gap_prevalence.py OWNERS row EXEC CICS: operand is not a data area: narrow it to data-area positions and give it the IBM citation rule 10 asks for (CICS TS 6.x "Data-areas and data-values", "COBOL argument values"). It needs an Opus review under rule 10, so it is left out of this PR.

Gates

  • tests/tools/box/heavy-run.sh python tests/tools/pr_gates.py --fast: 9/9 gates pass (lint, audits, secrets, xray, gen-docs, derived, workflows, gauntlet, affected), with CI's ruff 0.17.3 and mypy 2.4.1. Run before the main merge; the merge changed no file this PR touches beyond taking det/CICS WEB CONVERSE: SESSTOKEN and URIMAP take a constant, as IBM's data-values do (Part of #7959) #8057's identical text.
  • tests/cobol_mainframe/test_det_cics_operand_forms_7959.py: 37 passed (time ratchet: 0 over, 0 warned). Each fixed option is translated through P.translate with a literal and with a data name. A figurative constant is refused by name. Four data-area options (WEB READ FORMFIELD, DOCUMENT RETRIEVE DOCTOKEN, WEB SEND STATUSTEXT, WEB PARSE URL HOST) still refuse a literal.
  • Tree-wide guards (test_source_reads, test_cics_spec, test_proof_reach): 74 passed. tests/cobol_mainframe -k "web or operator or verify or system": 264 passed, 9 skipped.
  • Byte-identity: det_port.py check --base <HEAD-before-this-change translation> over every burned port using a changed command (zECS ecs001, zecs000-003, zecsnc, zecsplt; cics-crucible gt-web-client, gt-web-parse-url, gt-web-server-send, gt-web-server-receive, gt-http-inbound, gt-urimap-browse): 13/13 ports unchanged.
  • --ratchets not run: no port, golden or baseline input changed (13/13 ports byte-identical).

🤖 Generated with Claude Code

https://claude.ai/code/session_018srRvh3Fv4eomruTgx3VvY

squid-protocol and others added 3 commits November 7, 2026 20:09
…8058)

WEB CLOSE SESSTOKEN, WEB OPEN HOST, WEB SEND DOCTOKEN / MEDIATYPE, WEB PARSE URL, WEB WRITE HTTPHEADER SESSTOKEN, WEB READ QUERYPARM, WRITE OPERATOR TEXT / ROUTECODES and VERIFY PASSWORD USERID are IBM data-values (CICS TS 6.x syntax diagrams): Cics.value_text reads a literal as its value; a data name keeps its data-area text path byte-identical; a figurative constant is refused by name. Data-area options stay strict.

Co-Authored-By: Claude Opus 5.5 <[email protected]>
Claude-Session: https://claude.ai/code/session_018srRvh3Fv4eomruTgx3VvY
# Conflicts:
#	gitgalaxy/tools/cobol_to_java/det/cics_web.py
#	tests/cobol_mainframe/test_det_cics_operand_forms_7959.py
@squid-shepherd

squid-shepherd Bot commented Nov 8, 2026

Copy link
Copy Markdown
Contributor

No description provided.

@squid-shepherd
squid-shepherd Bot enabled auto-merge (squash) November 8, 2026 02:07
@github-actions

github-actions Bot commented Nov 8, 2026

Copy link
Copy Markdown
Contributor

🐦‍⬛ Muninn Security Scan

✅ No security issues found.

🐦‍⬛ Powered by Muninn · Skald Lab

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment