Repository navigation
CICS macro tables: DFHPPT PARTITIONSET= macro operand refused by name (Part of #5154) - #7379
Merged
Merged
Conversation
… (Part of #5154) SC33-1166-02 App. C p.378 lists PARTSET= only; no manual lists PARTITIONSET= as a macro operand, so it no longer yields a row. PARTSET= is unchanged. Co-Authored-By: Claude Sonnet 5.5 <[email protected]>
Contributor
|
No description provided. |
Contributor
|
No description provided. |
Contributor
Contributor
|
No description provided. |
This was referenced Nov 1, 2026
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
Part of #5154
Checklist: partial [c:e470afe9] -- SC33-1653-05 (VSE) and SH20-1043-6 page cites stay unverified (IBM VSE PDFs return 404 offline)
What
The DFHPPT
PARTITIONSET=macro operand was an ASSUMED alias ofPARTSET=. SC33-1166-02 App. C p.378 listsPARTSETonly, and no manual read listsPARTITIONSET=as a macro operand (it is the RDO word). IBM is the reference, so it is now REFUSED by name: the statement yields no row.PARTSET=is unchanged. Fixtures switched toPARTSET=; register X62 and the module header updated; a test pins the refusal.Class sweep
Class: CICS macro operands no manual lists, accepted as ASSUMED.
PARTITIONSET=PARTSETonly; test pinPARTSET=RECFORM=UNDEFINEDSibling gaps: none needing a burned-estate program (no burned estate holds a DFHPPT/DFHPCT source; git grep over all six). The unverified VSE/SPRM cites are the only open item.
Gates
pytest (macro tables, resource map, csd data): 248 passed; estate/tools cics subset: 431 passed; audit_check all clear; ruff format clean. No golden change expected (no scanned corpus holds the operand).
🤖 Generated with Claude Code