Repository navigation
cics macro tables: cite SC33-1166-02 for PCT/PPT/SDSCI operands; name what stays ASSUMED/REFUSED (Part of #5154) - #7368
Merged
Conversation
… what stays ASSUMED/REFUSED (Part of #5154) Co-Authored-By: Claude Sonnet 5.5 <[email protected]>
Contributor
|
No description provided. |
Contributor
Contributor
|
No description provided. |
This was referenced Nov 1, 2026
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
Part of #5154. Reads the three ASSUMED operand families in
gitgalaxy/core/cics_macro_tables.pyagainst IBM's CICS for MVS/ESA 4.1 Resource Definition Guide, SC33-1166-02 (public.dhe.ibm.com.../os390/dfhla414.pdf; downloaded to scratch and read as text). No extraction behavior changes: header comment, docstrings, the X62 register line and tests only.Checklist: partial [c:e470afe9] -- DFHPCT/PPT operands are cited and confirmed from SC33-1166-02; the SC33-1653-05 (VSE) and SH20-1043-6 pages could not be re-read (IBM's VSE PDFs
dfhwa400.pdf/dfhwa200.pdfreturn 404), so their existing cites stand unverified in this PR.Checklist: done [c:a248c3e3] -- CEDA/CEMT runtime state stays REFUSED by name (installed state is not in a source tree, register X62); no change needed.
What the manual settled
RECFORM=UNDEFINEDrecord_formatNone, text keptPARTSET=PARTSET-> PARTITIONSET (Partitionset and Transaction)PARTITIONSET=DTB=NOTests
New
test_dfhpct_restated_operands_follow_the_cross_reference_table(13 cases: every restated operand, range edges, DTB listed/unlisted combinations, same-name TWASIZE). The existing PPT alias and SDSCI word tests now carry the page cites. 282 pass in the two macro test files.Gates
pr_gates --fast9/9 and--ratchets9 pass (0 skipped). No golden bless: output is byte-identical (no parsing code changed).Class / Sibling gaps
Class: operands in the CICS macro-table reader whose mapping rested on an uncited or unread manual page (DFHPCT restated operands, DFHPPT PARTSET/PARTITIONSET, DFHDCT SDSCI RECFORM). Members handled: all three families above, each now cited to a page or named ASSUMED/REFUSED.
Sibling gaps (not here, different manual pages): DFHJCT
DSNAME=lifted though not in VSE Table 41 (ASSUMED); DFHTCT TRMIDNT length, repeated TRMIDNT/SYSIDNT,TYPE=REGIONscope to TERMINAL only, ACCMETH outside the listed four (ASSUMED); DFHMCT EMP repeated ID / CLASS / entryname length (ASSUMED);SUFFIX=NO|DYon TCT/MCT (ASSUMED). The VSE and SH20-1043-6 cites need a re-read when a readable copy is found.Lessons for agents
public.dhe.ibm.com/software/cics/pdf/dfha400.pdfand thevse/dfhwa*.pdfURLs 404;.../os390/dfhla414.pdf(CICS/ESA 4.1 RDG, SC33-1166-02) andpublibfp.dhe.ibm.com/epubs/pdf/dfha4d03.pdf(TS 4.1 RDG) download fine with curl.pdftotext -layoutthen grep; form feeds (\f) give page boundaries.🤖 Generated with Claude Code