Repository navigation
X17: IBM wording read for a PUT naming the other data type; not decisive, stays REFUSED (Part of #5005) - #7293
Conversation
…ive, stays REFUSED (Part of #5005) Co-Authored-By: Claude Sonnet 5.5 <[email protected]>
|
No description provided. |
|
PR #7293 @ 24c8b64: 1 failed check(s) == full-suite part 1/2 (failure) -- real |
Co-Authored-By: Claude Sonnet 5.5 <[email protected]>
|
CI shepherd: the head of this PR (58b2737) is not the one a maintainer labelled |
|
No description provided. |
|
PR #7293 @ 58b2737: 14 failed check(s) == db2 ${{ matrix.shard }} (cancelled) -- infra == det (failure) -- real == evidence report level deltas (advisory) (cancelled) -- infra == full-suite part ${{ matrix.group }}/${{ needs.shard-plan.outputs.splits }} (cancelled) -- infra == ground-truth (failure) -- infra == ground-truth part ${{ matrix.shard }} (cancelled) -- infra == ground-truth-warm (cancelled) -- infra == plan the suite parts (cancelled) -- infra == publish (cancelled) -- infra == publish-history (cancelled) -- infra == shard ${{ matrix.shard }} (cancelled) -- infra == store the suite's durations (cancelled) -- infra == suite time budget (#5166) (cancelled) -- infra == suite-plan (cancelled) -- infra |
|
No description provided. |
1 similar comment
|
No description provided. |
Part of #5005.
Records the IBM source for the "PUT naming the other data type for an existing container" refusal (X17) in the register and pins the quotes. IBM CICS TS 6.x, PUT CONTAINER (CHANNEL): DATATYPE "applies only to new containers" and "cannot be changed" for an existing one; INVREQ RESP2 33 is "an attempt ... to change the data-type of an existing container". The page never says the option is ignored, nor what a same-type DATATYPE does, so it is not decisive: the RuntimeRefusal stays. Burned reach is 0 (census pin from #7282). No engine change, no golden effect.
Checklist: partial [c:6daa978d] -- IBM text read but not decisive (ignore vs INVREQ 33 still open); the refusal stays and no burned program reaches it
Class and siblings
Class: CICS container commands whose behaviour on an existing container of the other data type IBM leaves open.
Sibling gaps: PUT64 CONTAINER (same refusal, covered here); MOVE CONTAINER onto an existing container of the other data type (
containers.py, X42), refused by name, no burned program needs it.Facts checked
The two quotes were read through a summarising fetch of the IBM page; re-check against the live page before relying on them.
Lessons for agents
None new.
🤖 Generated with Claude Code