Repository navigation
register: C13, C14, C4 cite IBM's text instead of assuming it (Part of #4702) - #5308
Merged
Merged
Conversation
…#4702) Re-read the 6.4 Language Reference and Programming Guide. C13: the nonnumeric comparison table admits only integer literals and zoned items, ZWB decides the sign; ZWB is not modelled (sibling gap). C14: Table 32 quoted; two oracle-vs-IBM differences named. C4: the arithmetic-store absolute-value rule stays inferred. cobolrt_rules.json ibm sections updated; calibration unchanged. Co-Authored-By: Claude Sonnet 5.5 <[email protected]>
Owner
Author
|
No description provided. |
squid-protocol
marked this pull request as ready for review
October 17, 2026 05:15
Owner
Author
|
No description provided. |
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
Part of #4702 (Phase 2: oracle policy audit, docs only).
What changed
0 ** -nwithout the phrase, and a negative base to a fractional power (IBM uses the absolute base).cobolrt_rules.json: threeibm.sectionnames corrected.calibrationstaysuncalibrated.Class and siblings
Class: register entries whose IBM side is assumed or not re-fetched. C13, C14 and C4 are covered here.
Sibling gaps
OPTION_TABLEor C5; the port assumes the default. Adding it needs a code change, a C5 row and a test. Burned estate program: none known (COTRTLIC compares an alphanumeric item with0, which stays valid).Gates
register.py --checkok;test_cobolrt_rules,test_support_matrix,test_option_table: 126 passed;pr_gates.py --fast: 6/6.test_det_programs -k EDCMPskipped locally (no cobc), so CI runs it. No engine output moved, so no golden bless.Plan change: the IBM PDFs (publibfp) were readable, so this found real differences instead of only confirming the text.