You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
{{ message }}
Repository navigation
det/CICS: a typed COMMAREA write-back rewrites the sign of a field the program never touched #7485
On a LINKed CICS program with a typed COMMAREA, the port changes bytes of a signed DISPLAY field the program never touched. caBack runs fill_ before it copies storage back to the link area. fill_ reads through Cobol.num, then Zoned.operand, and that read does GnuCOBOL's PUT_SIGN, so a read writes storage.
Reproduced with survivor_attack.py try on the real oracle:
cbsa-abndproc: ABND-RESPCODE (SIGN LEADING SEPARATE) sent as 9 spaces comes back as + and 8 spaces (numeric-all-spaces).
cbsa-updacc: COMM-AVAIL-BAL (S9(10)V99 overpunch) sent as spaces comes back with last byte {.
The WRITE'd record is right; only the returned COMMAREA is wrong. Mutant eea30fe38b deletes the fill_ caBack and is equal to the COBOL on that input, which shows the cause and refutes its equivalent verdict. Likely any LINKed port with a signed DISPLAY COMMAREA field holding non-digits; only these two were run. Evidence is GnuCOBOL, not z/OS.
Claimed by promoter-bot host melek, lease renewed 2026-11-03T12:01Z. It lapses after 6 h without a renewal. To take it back, assign someone or remove the claim:melek label.
Activity
squid-protocol commentedon Nov 3, 2026
Claimed by promoter-bot host
melek, lease renewed 2026-11-03T12:01Z. It lapses after 6 h without a renewal. To take it back, assign someone or remove theclaim:meleklabel.test: name the tmp case file link_case.json so the new test is not th…