det: a LINK writes the callee's DTO back over the caller's COMMAREA -- a numeric field holding spaces the callee never wrote comes back as digits (CBSA BNK1UAC -> INQACC) #4806
bugUnintended behavior or logic failure in the engineera:2Era CICS/MVS-ESA, COBOL II/85: RESP, SQL, DPL (~1988-96) (era_tags.py)legacy-modernizationCOBOL refractor, dead-code extraction, and JCL forgingpriority: mediumscope:coreBlocks a burned-estate program's next evidence rung, or the 4th-estate one-shot trial
Found writing the CBSA BNK1UAC equivalence case (#4270). The det port of a LINK passes the caller's COMMAREA to the callee as the callee's DTO and writes the DTO back over the caller's bytes afterwards (out_<Dto>(storage) before task.link(...), in_<Dto>(dto, storage) after). A numeric DISPLAY field of the callee's layout that holds spaces in the caller's storage (the callee never writes it) comes back changed: the DTO reads the spaces as a number (-16) and writes it back as digits.
Where. CBSA BNK1UAC INQ-ACC-DATA: it INITIALIZEs its own DFHCOMMAREA (COMM-CUSTNO PIC X(10), COMM-SCODE PIC X(6): spaces) and LINKs INQACC with it. INQACC's layout (INQACC copybook) has INQACC-CUSTNO PIC 9(10), INQACC-SCODE PIC 9(6) there. For an account that is not on file INQACC only sets INQACC-SUCCESS 'N' -- the rest of the area is the caller's.
COBOL (GnuCOBOL oracle, and z/OS): COMM-CUSTNO / COMM-SCODE are still spaces after the LINK.
det port: 0000000016 / 000016 (the RETURN COMMAREA's WS-COMM-CUSTNO / WS-COMM-SCODE, copied from them).
Expected. After a LINK, the caller's storage holds exactly the bytes the callee left in the COMMAREA (IBM: the COMMAREA is passed by address, so the callee changes the caller's storage in place). A byte the callee did not write must not change. The callee's port already takes the bytes (task.linkArea(), #4765). So the write-back should be those bytes, not a DTO round trip, or the DTO round trip must keep bytes it cannot decode. Never loosen the comparison: the case shows it as a COMMAREA difference.
Repro. The scratch generator for the case is in the #4270 CBSA cases handoff (handoff-4270-cbsa-whole-cases.md). Its scenario inquire-not-found (ENTER with ACCNO 00000050) is enough.
Blocks: an equivalence case for CBSA BNK1UAC. BNK1UAC is also blocked by #4695 (RETURN LENGTH(99) over its DTO). Part of #4270.
bugUnintended behavior or logic failure in the engineera:2Era CICS/MVS-ESA, COBOL II/85: RESP, SQL, DPL (~1988-96) (era_tags.py)legacy-modernizationCOBOL refractor, dead-code extraction, and JCL forgingpriority: mediumscope:coreBlocks a burned-estate program's next evidence rung, or the 4th-estate one-shot trial
Activity
det: XCTL bytes -- name the byte[] expressions apart from the LINK's …
WIP: det sweep coverage ledger from the #4806 sweep (52 changed ports…
equivalence: cases for the CBSA programs made whole (Part of #4270) (#…
det: RETURN TRANSID COMMAREA carries its bytes to the next task (Part…