You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
{{ message }}
Repository navigation
equivalence: CICS proofs do not compare DISPLAY output, and treat low-values as spaces (det-port mutation survivors, #4628) #4635
bugUnintended behavior or logic failure in the engineera:2Era CICS/MVS-ESA, COBOL II/85: RESP, SQL, DPL (~1988-96) (era_tags.py)legacy-modernizationCOBOL refractor, dead-code extraction, and JCL forgingpriority: highCore feature broken, but workarounds existscope:coreBlocks a burned-estate program's next evidence rung, or the 4th-estate one-shot trialtestingUnit, integration, and E2E pipeline verification
Found by det-port mutation testing (#4628): surviving mutants that change behaviour a CICS proof runs but does not compare. Part of #4270.
A CICS task's DISPLAY output is not compared. Batch proofs compare SYSOUT (Batch equivalence ignores DISPLAY / SYSOUT: a port that writes the wrong job-log message is still proven #4056); a CICS proof compares events, files and the COMMAREA, not what the task DISPLAYs (on z/OS: the job log / CEEMSG). The cbsa-abndproc case notes say so. ABNDPROC's det port: negating IF WS-CICS-RESP NOT = DFHRESP(NORMAL) survives (both branches end in the same RETURN; only the 'Unable to write to the file ABNDFILE' DISPLAYs differ), as do changed DISPLAY literals (mutants 4f2f93e07d, 5014504153, f758c610d2 in tests/equivalence/det_mutation_survivors.json).
Low-values and spaces compare equal.equivalence_cics._same strips trailing spaces AND low-values (rstrip(" \x00")) from text. A COMMAREA or screen field left low-values (RECEIVE MAP's clear of a field the terminal did not send) and one left spaces are different bytes to the next program (IF X = SPACES OR LOW-VALUES exists because they differ), but the proof cannot see it. COSGN00C's det port: deleting RECEIVE's clear of COSGN0AI survives (mutant 3ddaca02b1): USERIDI flows into CDEMO-USER-ID of the RETURN COMMAREA as spaces instead of low-values.
Both are recorded as harness-gap in the reviewed survivor list: triaged, NOT accounted for, so they block evidence level L5 for those programs until the harness compares them (the mutants are then killed and the entries drop).
bugUnintended behavior or logic failure in the engineera:2Era CICS/MVS-ESA, COBOL II/85: RESP, SQL, DPL (~1988-96) (era_tags.py)legacy-modernizationCOBOL refractor, dead-code extraction, and JCL forgingpriority: highCore feature broken, but workarounds existscope:coreBlocks a burned-estate program's next evidence rung, or the 4th-estate one-shot trialtestingUnit, integration, and E2E pipeline verification
Activity
evidence: refresh committed reports (#4635)
equivalence: CICS proofs compare DISPLAY output and keep low-values a…
det: SQLCODE -180 for a null-date update, not the driver's -4220 (#4658…
equivalence: a COMMAREA passed as bytes keeps its LOW-VALUES, as the …
det: LINK RESP2; RETURN/LINK COMMAREA LENGTH past the DTO passes the …
det runtime: browse/DELETE RESP2 as IBM states it; signon model port …
README: iterably-solvable claim (scoped) and an evidence-chain sectio…
README: show-then-prove front page for the scanner and the translator (…
mutation: reclassify 12 carddemo-userlist case-gap survivors (Part of #…