Repository navigation
test(server): shut down fixture upstream managers so no watcher or client outlives its test - #1936
Merged
Merged
Conversation
…ient outlives its test internal/server fixtures built upstream.Manager instances and never shut them down. Each kept its network-recovery watcher (#1931) ticking and its clients reconnecting to their fixture's closed port for the rest of the package run: 1273 watchers and 3196 goroutines were still alive after the last test of a full race run, and the reconnecting clients sent the stray requests that #1918 and #1934 worked around. - newTestUpstreamManager / shutdownUpstreamOnCleanup: every direct upstream.NewManager in the package now shuts down with ShutdownAll at test end (createTestProxyWithRuntimeCfg was 70% of the leak on its own). - stopUpstreamBeforeFixtureClose: fixtures that start an upstream after the manager (startCountingUpstream, prompt-upstream helpers) remove the client before the listener closes, so it never redials a closed port. The DisconnectAll cleanups these replace ran after the fixture closed. - mcp_code_execution_test.go (package server_test) defers the shutdown before its deferred storage close; scope_latency_test.go inlines it because the scope-latency workflow copies that file alone onto the merge base. - TestMain fails a passing run that leaves any (*networkRecovery).run goroutine behind (polled for 10s, first stacks printed). After: 0 watchers and 739 goroutines at the end of the same run.
Deploying mcpproxy-docs with
|
| Latest commit: |
c223c59
|
| Status: | ✅ Deploy successful! |
| Preview URL: | https://551ad7dd.mcpproxy-docs.pages.dev |
| Branch Preview URL: | https://test-server-fixtures-shutdow.mcpproxy-docs.pages.dev |
Dumbris
enabled auto-merge (squash)
November 19, 2026 11:22
Contributor
📦 Build ArtifactsWorkflow Run: View Run Available Artifacts
How to DownloadOption 1: GitHub Web UI (easiest)
Option 2: GitHub CLI gh run download 44513075638 --repo smart-mcp-proxy/mcpproxy-go
|
|
Codecov Report✅ All modified and coverable lines are covered by tests. 📢 Thoughts on this report? Let us know! |
Dumbris
added a commit
that referenced
this pull request
Nov 19, 2026
TestE2E_TrayToCore_UnixSocket, TestE2E_DualListener_Concurrent and TestE2E_SocketPermissions never shut their server down, so each left its upstream manager's network-recovery watcher running. Since the TestMain leak guard (#1936) that fails the -run TestE2E job on main. Shut each server down in a defer that runs before the socketE2EMutex unlock.
Dumbris
added a commit
that referenced
this pull request
Nov 19, 2026
TestE2E_TrayToCore_UnixSocket, TestE2E_DualListener_Concurrent and TestE2E_SocketPermissions started a Server and deliberately never shut it down. Each one left its runtime, upstream manager and network-recovery watcher running, so the TestMain guard from #1936 failed the E2E job (`-run TestE2E`) with "3 upstream.Manager network-recovery watcher(s) still running". #1936's sweep ran with `-skip E2E` and never saw them. stopSocketE2EServer shuts the server down, cancels its context and waits for Start to return. It is deferred after the socketE2EMutex unlock, so it runs while the mutex is held, before the next socket test starts. Verified: the guard fails with the three tests on the old file and passes with this change; the CI E2E command passes.
Dumbris
added a commit
that referenced
this pull request
Nov 19, 2026
TestE2E_TrayToCore_UnixSocket, TestE2E_DualListener_Concurrent and TestE2E_SocketPermissions started a Server and deliberately never shut it down. Each one left its runtime, upstream manager and network-recovery watcher running, so the TestMain guard from #1936 failed the E2E job (`-run TestE2E`) with "3 upstream.Manager network-recovery watcher(s) still running". #1936's sweep ran with `-skip E2E` and never saw them. stopSocketE2EServer shuts the server down, cancels its context and waits for Start to return. It is deferred after the socketE2EMutex unlock, so it runs while the mutex is held, before the next socket test starts. Verified: the guard fails with the three tests on the old file and passes with this change; the CI E2E command passes.
Dumbris
added a commit
that referenced
this pull request
Nov 20, 2026
…wn (#1941) ## Problem `NewServer` starts two goroutines that `Server.Shutdown` never stopped: - `forwardRuntimeStatus` ranges over `Runtime.StatusChannel()`. Nothing closes that channel. - `listenForRoutingModeRefresh` ranges over a `SubscribeEvents()` channel. `Shutdown` never unsubscribed it. In a real process this does no harm because the process exits. But every server that is shut down inside a running process (tests, an in-process restart) leaves two idle goroutines behind for the rest of the process. ## Fix (`internal/server/server.go`) - `Server` now stores the routing subscription (`routingEventsCh`), and `Shutdown` unsubscribes it. `UnsubscribeEvents` closes the channel, which ends the listener's range loop. The listener's own deferred `UnsubscribeEvents` then finds no subscription left and does nothing. - The forwarder now `select`s on a server-owned `listenersDone` channel, which `Shutdown` closes. The runtime's `statusCh` stays open, so a status send can never hit a closed channel. - Both steps run inside the existing `s.shutdown` guard, so a second `Shutdown` is still a no-op and `listenersDone` is closed only once. ## Tests - New `TestShutdown_StopsServerListenerGoroutines` (`internal/server/shutdown_listeners_test.go`): builds a server with `NewServer`, calls `Shutdown`, and polls (10s deadline) until neither frame is running above the count taken before `NewServer`. It then calls `Shutdown` a second time. It failed before the fix (`1/1` of each still running after 10s) and passes after it (`-race -count=5`). - Full `go test -race -timeout 60m -skip "E2E|Binary|MCPProtocol|TestInfoEndpoint|TestGracefulShutdownNoPanic|TestSocketInfoEndpoint" ./internal/server/` passes on both trees. Goroutines still running at the end of the run (counted by a local-only `TestMain` that was not committed): | | total | `forwardRuntimeStatus` | `listenForRoutingModeRefresh` | |---|---|---|---| | `main` 58a824e | 3194 | 227 | 227 | | this branch | 2736 | **0** | **0** | - golangci-lint v2 with `.github/.golangci.yml`, bare and `--build-tags server`, with `--new-from-rev=origin/main`: 0 issues. ## Not in this PR The `TestMain` leak guard from #1936 (`leak_guard_main_test.go`) is not on `main` yet. Once both PRs land, it can also check these two frames, since a full run now ends at zero. ## Also: E2E job red on `main` since #1936 The `-run TestE2E` job has failed on `main` since #1936 (6251956, 201d373): `FAIL: 3 upstream.Manager network-recovery watcher(s) still running`. I traced the creators with pprof labels. All three are the socket E2E tests (`TestE2E_TrayToCore_UnixSocket`, `TestE2E_DualListener_Concurrent`, `TestE2E_SocketPermissions`), which deliberately never shut their server down. Each test now shuts its server down in a `defer` that runs before the `socketE2EMutex` unlock. The CI E2E command (`go test -v -race -timeout 10m ./internal/server -run TestE2E -skip '…'`) now passes locally (255s), and the three tests pass with `-race -count=3`.
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
Summary
Test-only.
internal/serverfixtures createdupstream.Managers and never shut them down. Each one kept its network-recovery watcher (#1931) running, and its clients kept reconnecting to their fixture's closed port, for the rest of the package run. Those reconnects are the stray traffic that #1918 (fresh-process allocation tests) and #1934 (retire-fixture isolation) worked around. This PR fixes the source.The numbers below come from the end of a full
go test -v -race -timeout 60m -coverprofile … -skip "E2E|Binary|MCPProtocol|TestInfoEndpoint|TestGracefulShutdownNoPanic|TestSocketInfoEndpoint" ./internal/server/run:(*networkRecovery).runstartOAuthEventMonitormillRunTo find the sources, I labelled each watcher goroutine with the test frame that created it (a temporary local patch, not committed). Every leaked watcher came from a direct
upstream.NewManagerin a test file.createTestProxyWithRuntimeCfgalone accounted for about 70% of them. None came from a runtime or server that wasn't closed.Changes
newTestUpstreamManager/shutdownUpstreamOnCleanup(upstream_fixture_cleanup_test.go): all 37 directupstream.NewManagercalls in the package now callShutdownAllwhen the test ends. This includes the sharedcreateTestProxyWithRuntimeCfg.stopUpstreamBeforeFixtureClose: some fixtures start their upstream after the manager exists:startCountingUpstreamand the prompt-upstream helpers inmcp_prompt_scope_test.goandscope_retained_effects_test.go. They now remove the client in a cleanup registered after the listener's close, so it runs first: the client disconnects while the stub still listens and never redials a closed port. The oldDisconnectAllcleanups in the prompt loops ran after the fixture had already closed.mcp_code_execution_test.go(packageserver_test) defers the shutdown so it runs before the storage close it depends on.scope_latency_test.goinlines the shutdown, becausescope-latency.ymlcopies that one file onto the merge-base checkout, where the helper doesn't exist.TestMain(leak_guard_main_test.go) fails an otherwise passing run if any(*networkRecovery).rungoroutine is still alive after the last test. It polls for up to 10s and prints the first 5 stacks. I checked that it catches a leak: with the helper's shutdown commented out,-run TestAggregatedPrompt_ScopeUsesCanonicalOwnerfails with "2 upstream.Manager network-recovery watcher(s) still running".TestE2E_TrayToCore_UnixSocket,TestE2E_DualListener_ConcurrentandTestE2E_SocketPermissionsnever cancelledStart's context or shut the server down, an old workaround for a shutdown race. Each left a runtime and its manager running, and the guard failed the E2E job on those 3 watchers. They now stop throughstopSocketE2EServer: cancel, wait forStartto return, thenShutdown. They pass-race -count=3, and a full-race -run TestE2Erun leaves 0 watchers.MCPPROXY_NETWORK_RECOVERY=offis not set anywhere.No production code changed. The leaks were all in test fixtures.
Found, not fixed (production shutdown gap)
The 739 goroutines that remain are mostly 227 ×
(*Server).forwardRuntimeStatusand 227 ×(*Server).listenForRoutingModeRefresh.NewServerstarts both (server.go:488,:504), andServer.Shutdownstops neither:listenForRoutingModeRefreshranges over aSubscribeEventschannel that is never unsubscribed.forwardRuntimeStatusranges overRuntime.statusCh, which nothing closes.They sit idle on a channel receive and send no network traffic. They are harmless in a real process, which exits after
Shutdown. In tests they are still 2 leaked goroutines per server. I left them for a separate production change.Verification