read_h5mu() fails on files written by mudata <= 0.1.1 (encoding-type "AnnData") #209
Since mudata 0.4, read_h5mu() can no longer read .h5mu files written by mudata 0.1.1 or older. Those versions stored each modality with the attribute encoding-type = "AnnData" (capital A), while mudata 0.1.2 and later write "anndata". As modality groups are now read through anndata's IO registry, which only knows the lowercase spelling, the read fails:
anndata._io.specs.registry.IORegistryError: No read method registered for
IOSpec(encoding_type='AnnData', encoding_version='0.1.0') from <class 'h5py._hl.group.Group'>.
This was found in anndataR (scverse/anndataR#511), which currently pins mudata<0.4 because its example file minipbcite.h5mu was written by an old mudata. The existing backwards-compatibility tests start at files from v0.1.2, which is why the regression wasn't caught.
Minimal reproduction, simulating an old file by setting the legacy attribute:
python
import numpy as np, anndata as ad, mudata as md, h5py
m = md.MuData({"rna": ad.AnnData(np.ones((3, 2)))})
m.write("legacy.h5mu")
with h5py.File("legacy.h5mu", "r+") as f:
f["mod/rna"].attrs["encoding-type"] = "AnnData" # as written by mudata <= 0.1.1
md.read_h5mu("legacy.h5mu") # IORegistryError
The same file reads fine with mudata 0.3.10.
A possible fix would be to treat the legacy "AnnData" encoding type as "anndata" when reading modalities, and to add a test for a pre-0.1.2 file.