You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
{{ message }}
Repository navigation
E6 knee detector is noise-sensitive: use multi-sample rungs / warm baseline #62
From the P3 OCP authoritative run (PR for OCP results, epic #49). deploy/knative/e6-saturation.sh + experiments/src/sharing.tsdetectKnee require throughput to rise strictly vs the previous rung. Per-leaf model-latency and Knative cold-start variance make a single rung's throughput dip below its predecessor (observed on OCP: c=4 0.213 < c=2 0.245), tripping the knee break early and failing the sanity floor — a measurement-noise artifact, not a real saturation knee.
Fix ideas: run each ladder rung N times and use the median/best throughput; and/or pre-warm the harness (min-scale=1) to remove cold-start noise from the C=1 baseline and the sweep; and/or smooth throughput (only break on a sustained multi-rung decline). Goal: a stable, representative per-sandbox knee. The duty-cycle/derived-N result is already robust (~2-4%, N ~29-48:1 across Kind+OCP); this is specifically about the knee.
Verified addressed on main by PR #63. detectKnee no longer requires a strict rise vs the previous rung — it compares against the running-max throughput and breaks only after patience (default 2) consecutive unhealthy rungs (sustained decline). e6-saturation.sh adds median-of-N sampling (E6_SAMPLES=3) per rung and a warm min-scale=1 pinned baseline to remove cold-start noise. All three fix ideas landed. Closing.
Activity
Merge pull request #63 from kagenti/feat/e6-workload-parameterization
pdettori commentedon Jul 6, 2026
Verified addressed on
mainby PR #63.detectKneeno longer requires a strict rise vs the previous rung — it compares against the running-max throughput and breaks only afterpatience(default 2) consecutive unhealthy rungs (sustained decline).e6-saturation.shadds median-of-N sampling (E6_SAMPLES=3) per rung and a warmmin-scale=1pinned baseline to remove cold-start noise. All three fix ideas landed. Closing.Assisted-By: Claude Code