Repository navigation
[Data][Delta DSv2][7/7] Read Delta Lake tables through DataSourceV2 by default - #67679
abhishekverma-ray wants to merge 7 commits into
Conversation
672c310 to
73ec13e
Compare
73ec13e to
f8a7e5b
Compare
f1a9b6e to
35703c5
Compare
There was a problem hiding this comment.
Code Review
This pull request introduces a new DataSourceV2 implementation for Delta Lake tables (DeltaDatasourceV2), enabling read_delta to leverage the DataSourceV2 pipeline. It includes a log-based file indexer (DeltaFileIndexer), a Parquet-based scanner (DeltaScanner), and log statistics pruning (delta_file_pruning.py) to skip files based on query predicates. Additionally, support for Hive-style partitioning with null fallbacks has been added along with comprehensive unit and end-to-end tests. One piece of feedback suggests improving absolute path detection on Windows by checking for drive letters in resolve_data_file_path.
| (for example for shallow clones), but the DataSourceV2 reader reads | ||
| through a filesystem rooted at the table. | ||
| """ | ||
| if posixpath.isabs(logged_path) or _has_scheme(logged_path): |
There was a problem hiding this comment.
On Windows, absolute paths can start with a drive letter (e.g., C:/path or C:\\path). Since posixpath.isabs only checks for a leading slash, and _has_scheme returns False for single-letter drive schemes, Windows absolute paths won't be detected as absolute. This can lead to confusing errors later when trying to read them as relative paths. Consider checking for Windows drive letters as well.
| if posixpath.isabs(logged_path) or _has_scheme(logged_path): | |
| if posixpath.isabs(logged_path) or _has_scheme(logged_path) or (len(logged_path) > 1 and logged_path[1] == ':'): |
a1c1597 to
324dc0f
Compare
d640ed7 to
18b2be4
Compare
There was a problem hiding this comment.
Cursor Bugbot has reviewed your changes using default effort and found 1 potential issue.
Reviewed by Cursor Bugbot for commit 18b2be4. Configure here.
Add the listing for the Delta Lake DataSourceV2 reader. A Delta table's data files are the ones its transaction log names at a version, not whatever the table directory holds, so the indexers here read the file list from the log instead of walking directories: - `DeltaTableSnapshot`: a picklable reference to one table version. A `deltalake.DeltaTable` can't be pickled, so listing tasks reopen the table from it at the version the driver pinned. - `DeltaFileIndexer(_DeltaLogListing, FooterFileIndexer)`: lists the `add` actions, then reads each file's Parquet footer, so listing rows are row-group runs (pruning, read units and resume as for Parquet). - `DeltaWholeFileIndexer`: the log-based listing for metadata-only reads. `FooterFileIndexer.as_whole_file_indexer` would walk the directory. - Paths are relative to the table root and URL-decoded once. Partition values come from Hive-style directories, parsed with `null_fallback=HIVE_DEFAULT_PARTITION`; a file not under them, or a partition value that is literally `__HIVE_DEFAULT_PARTITION__`, fails the listing instead of reading wrong values. - The indexer carries the table's filesystem and the read's shuffle, since the framework passes neither to a metadata-backed source. Nothing uses the indexers yet: the datasource and `read_delta` wiring follow in separate PRs. Co-authored-by: tobby168 <[email protected]> Co-Authored-By: Claude Opus 5.5 <[email protected]> Signed-off-by: Abhishek Verma <[email protected]>
The listing took each file's partition values from its Hive directory and dropped the ones the log records, so it failed tables the V1 reader reads: files outside partition directories (the Delta protocol doesn't require them) and the string `__HIVE_DEFAULT_PARTITION__`, which shares a directory with null values. Now the listing reads the values from the `add` actions: - `partition_values_as_strings` casts them to the table's types and back to strings with Arrow, the form the reader casts back exactly, as it does a value parsed from a path. - `DeltaPartitionPruner` evaluates the pushed-down partition predicate on those values. - Both indexers add them to each manifest in `PARTITION_VALUES_COLUMN`, which the bin packer carries to the read tasks. The reader that uses it comes with the datasource. The two directory checks go. Also drop the unused `list_files_from_file_infos` override and `DeltaWholeFileIndexer`'s `shuffle_config`, and the unit tests that the `read_delta` tests cover. Co-Authored-By: Claude Opus 5.5 <[email protected]> Signed-off-by: Abhishek Verma <[email protected]>
Add `DeltaDatasourceV2`, a `DataSourceWithMetadata` for one version of a Delta Lake table, and `DeltaScanner`: - The driver opens the log without its file list, pins the version and takes the schema and partition columns from the log; listing goes through the `DeltaFileIndexer` from the previous PR. - Data files are Parquet: `DeltaScanner` is a `ParquetScanner`, so the filter, column and limit pushdown are inherited. Partition columns keep their place in the output, and an `include_paths` `path` column comes last, as with the V1 reader. - Partition values come from the log, not from the paths: `DeltaScanner` prunes partitions with `DeltaPartitionPruner`, which the listing applies to each file's values, and reads with `DeltaFileReader`, a `ParquetFileReader` that takes each file's values from the manifest. `ParquetScanner` gets a `reader_class` attribute for that. - Everything is read through a filesystem rooted at the table directory, as `DeltaTable.to_pyarrow_dataset` does: the caller's, or a `deltalake` `DeltaStorageHandler` built from `storage_options`. - `delta_datasource_v2_unsupported_reason` says why a table must stay on the V1 reader: reader features beyond `timestampNtz` (deletion vectors, ...), column mapping, a partition column type whose values don't round-trip through a string (binary, ...), PyArrow scan options, or a table `path` column with `include_paths`. - `generated_id_column` rejects Delta reads for now. - The pickle gate scan allowlists `delta_datasource_v2.py`, whose only match is a schema `.to_arrow()`; data files are read and gated in `ParquetFileReader`. `read_delta` doesn't use the datasource yet; that wiring follows in a separate PR. Co-authored-by: tobby168 <[email protected]> Co-Authored-By: Claude Opus 5.5 <[email protected]> Signed-off-by: Abhishek Verma <[email protected]>
Route `read_delta` through `DeltaDatasourceV2` when the new `DataContext.use_delta_datasource_v2` (env `RAY_DATA_USE_DELTA_DATASOURCE_V2`, default off) and `use_datasource_v2` are both set. The driver then opens only the log (`without_files=True`), and tables `delta_datasource_v2_unsupported_reason` rejects keep using the V1 reader, with an info log saying why. Reads that pass `partition_filters` also use the V1 reader: the V2 reader doesn't apply them yet, so it would read every partition. Every `test_delta.py` test now runs under both readers (except the V1 listing's no-`get_file_info` check: V2 lists in Ray tasks, and `test_delta_file_indexer.py` covers its log sizes), and `test_delta_v2.py` checks that V2 returns the same rows and schema as V1 for partitioned tables, filters, `columns=`, `include_paths` and a table-rooted `filesystem=`, plus count after overwrite, version pinning, row-group read units, resume, shuffle and the V1 fallbacks. Tables whose paths don't give their partition values (random file prefixes, timestamp partitions with a time zone, the string `__HIVE_DEFAULT_PARTITION__` next to nulls) read the same through V2, with and without a filter on the partition column. Co-authored-by: tobby168 <[email protected]> Co-Authored-By: Claude Opus 5.5 <[email protected]> Signed-off-by: Abhishek Verma <[email protected]>
The DataSourceV2 Delta reader lists every data file of the pinned version and reads every footer. Each `add` action in the log carries the file's per-column minimum and maximum, so a file whose range proves no row can match the read's predicate is now left out of the listing, before its footer is read (ray-project#61547). Skipping is conservative: anything unprovable keeps the file, and the reader still applies the predicate to every row. Only bounds that are exact for their type are used: string maximums can be truncated by the writer, timestamp statistics are stored in milliseconds, and float bounds may be NaN. Supports comparisons with a literal on either side, IN, AND and OR. Co-authored-by: tobby168 <[email protected]> Co-Authored-By: Claude Opus 5.5 <[email protected]> Signed-off-by: Abhishek Verma <[email protected]>
A generated ID names a row's place in its Parquet data file. Delta data files never change, so the DataSourceV2 Delta reader, whose scanner is a `ParquetScanner`, can produce them: a job resumed against the same table version finds every ID again, and its listing skips the finished files and row groups. `read_delta` without `version=` reads the version that is latest when the dataset is created, so a resumed job may read a newer one, and rows a commit in between rewrote into new files (compaction, an overwrite) get new IDs and are processed again. Binding the column warns once in that case and asks for `version=`. Co-Authored-By: Claude Opus 5.5 <[email protected]> Signed-off-by: Abhishek Verma <[email protected]>
Turn `DataContext.use_delta_datasource_v2` on by default, so `read_delta` pins the table version when called, lists the data files in Ray tasks, skips files using the log's statistics and reads row-group read units. Tables the DataSourceV2 reader can't read yet still use the V1 reader. Opt out with `RAY_DATA_USE_DELTA_DATASOURCE_V2=0`. The flip is its own change so it can be reverted alone. Co-Authored-By: Claude Opus 5.5 <[email protected]> Signed-off-by: Abhishek Verma <[email protected]>
18b2be4 to
7c9a362
Compare
|
Closing in favor of #68286. Richard asked for the remaining Delta DSv2 PRs as a GitHub stack, so they now live on branches in The stack is https://github.com/ray-project/ray/stack/68288, and each PR now shows only its own diff. Earlier review comments stay here for reference. Please leave new comments on #68286. |

Summary
Turns
DataContext.use_delta_datasource_v2on by default. Stacked on #67677 and #67678. Kept separate so it can be reverted alone.Before
read_deltauses the V1 reader unless the flag is set.After
read_deltauses the DataSourceV2 reader (version pinned at call time, listing in Ray tasks, log-statistics file skipping, row-group read units, generated-ID checkpointing). Tables it can't read yet still use V1. Opt out withRAY_DATA_USE_DELTA_DATASOURCE_V2=0orDataContext.use_delta_datasource_v2 = False.Subsystems
IO (
DataContextdefault,read_deltadocstring).Testing
tests/unit/datasource_v2/— 883 passed;test_catalog.py(catalog-vended filesystems throughread_delta) — 46 passed;test_checkpoint.py— 97 passed.AI assistance was used (Claude Code); every line has been reviewed by the submitter.
🤖 Generated with Claude Code