Repository navigation
[core][gcs][Actice-Passive] Phase 2.3 Passive head lifecycle change - #66222
Conversation
There was a problem hiding this comment.
Code Review
This pull request implements the active-passive GCS leader election promotion path, deferring table loading and shared-storage writes until a GCS instance is promoted to leader. It introduces PromoteToLeader in GcsServer to handle manager hydration and node manager promotion, and updates GcsNodeManager to cache and register the local head node upon promotion. Feedback on these changes highlights a potential data race in PromoteToLeader if called from external threads, suggesting that the method's body be posted to the default IO context. Additionally, a potential use-after-free vulnerability was identified in the cluster ID retry timer callback within GetOrGenerateClusterId if the server is destroyed while the timer is pending.
|
This is one of the most refactor pr of active-passive implementation. |
Make startup safe for a standby head that shares storage with an active leader. All of it sits behind GcsServerConfig::ray_leader_elect_enabled, which nothing assigns yet, so the default path is unchanged. A passive boot skips the table load and every shared-storage write, resolving only the cluster ID before starting the RPC server so health checks and the allowed RPCs still work; table loading moves to promotion. A passive GCS waits for the leader's cluster ID rather than minting one. The GCS-pid and autoscaler-v2-flag writes move into WriteGcsPid() and WriteAutoscalerV2Flag(), still inline when leader election is off. Metrics are deliberately left on: a standby tags them with its own NodeAddress, so it stays observable rather than dark until promoted. Tests (gcs_server_rpc_test): - TestPassiveServerReadiness: adopts the leader's cluster ID, serves health checks, reports is_leader=false. - TestPassiveWaitsForClusterIdAndNeverWritesIt: stays unstarted while storage has no ID, proving it wrote none, and starts once a leader writes one. Signed-off-by: Yuchen Zhou <[email protected]>
d2b8c19 to
ed3d226
Compare
There was a problem hiding this comment.
Cursor Bugbot has reviewed your changes using default effort and found 1 potential issue.
Reviewed by Cursor Bugbot for commit ed3d226. Configure here.
|
change LGTM, one last comment from cursor I think is valid and then will approve |
ed3d226 to
8acdd9a
Compare
While passive, the leader-gated NodeInfo handler stashes the local head node's registration in GcsNodeManager's passive_local_node_ cache instead of persisting it. Nothing consumed that cache, so a promoted GCS would serve a head node that exists only in its own memory. PromoteNodeManager() replays the cached head through the normal HandleRegisterNode path. Going through the real handler is what makes the entry persist, publish NODE_ADDED, and -- because head registration marks every alive head dead -- retire the stale head hydrated from storage; otherwise the cluster reports two live heads after a failover. The cache is read rather than taken, and released from the registration callback. Registration retires the stale head from alive_nodes_ synchronously, but the promoted head only lands there after two chained storage writes: the stale head's DEAD record, then its own. Taking the cache up front would leave the head in neither place for that whole window, so CheckAlive, GetAllNodeInfo and GetAllNodeAddressAndLiveness -- un-gated, and already answering for a GCS that has set is_leader_ -- would report no live head, and a head that was visible before promotion and after it would appear to vanish in between. The callback runs from HandleRegisterNode's completion handler, which still holds mutex_ and has already populated alive_nodes_, so the handover is one critical section. Readers skip the cache once alive_nodes_/dead_nodes_ knows the id, so it is never double-counted while both hold it. No production caller yet; the GcsServer side that hydrates and then calls this is the next commit, and the header documents that ordering as a precondition. Tests (gcs_node_manager_test), under GcsNodeManagerPromotionTest whose AllNodes() helper also asserts no node id is reported twice: - TestPromoteRegistersCachedHeadAndKillsStaleHead: the cached head becomes alive, the hydrated stale head is marked dead, and a second promotion registers nothing again. - TestPromoteIsNoopWithoutCachedHead: the default path, where nothing was cached, must not invent a registration. - TestCachePassiveLocalNodeSkipsWhenPromoted: registration is async, so this covers the window after promotion but before alive_nodes_ is populated, where only the leadership check can reject a late call. - TestHeadStaysVisibleDuringPromotionHandover: mid-handover, with the stale head already retired and the storage write still in flight, the promoted head must already answer CheckAlive and the alive-head query. Signed-off-by: Yuchen Zhou <[email protected]>
A passive GCS never loaded the GCS tables and skipped the shared-storage writes, so nothing yet turns one into a working leader. PromoteToLeader() loads those tables, hydrates the managers, opens the RPC gate, registers the head node cached while passive, and performs the deferred writes. Order matters: hydrate, then flip is_leader_, then promote the node manager. Flipping earlier serves mutating RPCs against half-loaded state; promoting earlier registers the local head before the stale one is loaded, leaving the cluster reporting two live heads. HydrateManagers() covers fewer managers than DoStart. By promotion time the node-added listeners are installed, so loading the node table already fans every alive node out to the resource, placement group, autoscaler and health check managers; hydrating those again applies each node twice, which GcsHealthCheckManager::AddNode RAY_CHECKs against. Promotion is guarded on IsLeader() || promotion_started_. Neither alone is enough: is_leader_ only flips once the load completes, so a call in that window would start a second load, while promotion_started_ misses a GCS already active without having run this path. A second load hydrates twice, and GcsJobManager bumps a per-job reference count that would never drop back to zero. Promotion arriving while Start() is parked on the cluster-ID wait flips is_leader_ rather than returning: that wait only ends when a leader writes the ID, and that leader is now us. The continuation then boots active and must run WriteActiveOnlyKeys() too, since the init-time writes are skipped whenever leader election is enabled. RecordMetrics moves into StartMetricsReporting(), shared with promotion, because it writes usage counters to shared storage and a passive GCS would overwrite the leader's counts with zeroes -- a GCS-initiated write the RPC gating cannot catch. PrintDebugState keeps running while passive so a standby is not dark. No production caller yet; the elector's on_started_leading will drive it, on the single-threaded default io context so it cannot interleave with Start(). Tests (gcs_server_rpc_test), against the only topology a real cluster produces: GcsLeaderElectionTestBase starts no GCS, GcsLeaderElectionTest adds one promoted leader, promotion is posted onto the server's own io context the way the elector will, and assertions that must distinguish persisted state from an in-process cache read Redis directly. - TestColdStartPromotionBootsWinnerAndLoser: two candidates park against empty storage writing nothing; promoting one releases its own cluster-ID wait, writes the three keys, and unblocks the other, which stays passive on the same ID. - TestPromotionActivatesTheServer: GcsPassive and an empty node table before, serving the persisted node and accepting registrations after. - TestPromotionHandsOverTheHeadNode: the cached local head reaches storage only at promotion, the head it replaces is retired, and exactly one head stays alive, which is what pins the hydrate-then-register order. - TestPromotionRewritesActiveOnlyKeys: claims the GCS pid and autoscaler-v2 flag instead of leaving the previous leader's values. - TestPromotionIsIdempotent: both calls issue from one handler, so the second lands while the first is still loading tables. Signed-off-by: Yuchen Zhou <[email protected]>
The passive and promotion paths were unreachable: nothing assigned GcsServerConfig::enable_gcs_leader_election, so every GCS booted active. Read it from RayConfig, which picks up the RAY_ENABLE_GCS_LEADER_ELECTION env var. The default is still false, so a normal cluster is unaffected. Rename the field from ray_leader_elect_enabled while wiring it up. It was named after RAY_LEADER_ELECT, the env var this feature used before review renamed it, so the whole feature now greps as one name and matches the struct's other enable_* fields. Enabling it is not yet useful: nothing drives promotion, so the GCS stays passive and a lone head blocks in startup waiting for a cluster ID nobody writes. Warn at startup rather than let that look like a hang; the warning goes once the elector is wired up. No unit test covers main(), so this was verified against the built binary: the default run is unchanged, and with the env var set the GCS logs the warning, starts passive, and parks on the cluster-ID wait without ever writing one. Signed-off-by: Yuchen Zhou <[email protected]>
Signed-off-by: Yuchen Zhou <[email protected]>
… a lost CAS Signed-off-by: Yuchen Zhou <[email protected]>
…steners GcsNodeManager::Initialize() notified the node-added listeners for every node it restored. In DoStart that is a no-op: InstallEventListeners() runs after it, so the listener list is still empty, and each manager is hydrated by its own InitXxx(). On the promotion path the listeners are already installed, so the node table load drove them instead -- and Postable::Post() enqueues rather than runs inline, so they only drained after promotion had already finished. Two consequences: - GcsPlacementGroupManager::Initialize() ends in SchedulePendingPlacementGroups() and ran while gcs_resource_manager_ still had no nodes, so every persisted placement group went straight to INFEASIBLE and was only rescheduled once the queued events drained. - The previous leader's head node, loaded from storage, reached the listener's metrics branch and took the one-shot metrics_exporter_initialized_ latch with its own agent port. InitMetricsExporter() pairs that port with GetLocalhostIP(), the latch never resets, and a failed WaitForServerReady() is not retried, so the local head's port was ignored for the life of the process. Initialize() no longer notifies, and HydrateManagers() hydrates every manager explicitly in the order DoStart uses. The health check hydration loop moves out of InitGcsHealthCheckManager() so both paths share it. DoStart is unchanged: its listener list is empty at that point, so the suppressed notifications never happened there to begin with. Signed-off-by: Yuchen Zhou <[email protected]>
…erform LeaderGatedNodeInfoHandler::HandleRegisterNode checks is_leader_fn_() on the node manager's io context, then caches the head node, then replies OK unconditionally. The cache re-checks leadership under mutex_, and if promotion landed on the default io context in between it returned without caching. The raylet still got OK, treats the node as registered and never retries, so a head that nothing else registers is lost: no entry in the node table, no health check, and nothing in ray.nodes(). CachePassiveLocalNode becomes TryHandlePassiveHeadRegistration and reports whether the registration was handled. "Cache" did not match the return value: two of the three true cases do not cache anything. Handling does -- the node is handled when it is freshly cached, when alive_nodes_/dead_nodes_ already tracks it, and when it is the head the in-flight promotion is registering. It is unhandled only when this GCS is the leader and the promotion is registering a different head, and the handler then falls through to the real HandleRegisterNode instead of acknowledging it. The alive/dead check moves ahead of the leadership check, since a node already in the table is handled no matter who is leader. Returning false there would send an already-registered head back through registration, which retires it as a stale head and broadcasts it DEAD. Signed-off-by: Yuchen Zhou <[email protected]>
8acdd9a to
7c61169
Compare
…ay-project#66222) ## Description Third slice of the Phase 2 split of ray-project#64422. Earlier slices landed the passive interface (proto / `StatusCode::GcsPassive` / config / client) and the server-side RPC gating. This PR focuses on the passive GCS lifecycle including cold start and promotion. Everything is behind `RAY_ENABLE_GCS_LEADER_ELECTION`, **default off**. Please note that the gcs has not connected to the elector. There is no caller to trigger the promotion yet. <img width="836" height="953" alt="image" src="https://github.com/user-attachments/assets/7afd55fc-796e-401f-9f0c-e15c4224e296" /> ## Key changes **1. Passive boot — `gcs_server.{h,cc}`** - Skip the GCS table load and every shared-storage write. Resolve only the cluster ID and start the RPC server, so health checks and the un-gated (visibility) RPCs work while passive. Table loading moves to promotion. - `GetOrGenerateClusterId()` is restructured into three explicit branches; the new one is "no cluster ID yet **and** passive" → wait for the leader to write it (1s retry, rate-limited log) instead of minting one. - The GCS-pid and autoscaler-v2-flag `Put()`s are extracted into `WriteGcsPid()` / `WriteAutoscalerV2Flag()`, still called inline when leader election is off. - `RecordMetrics()` and the startup metrics-exporter init move into `StartMetricsReporting()`, now active-only: `RecordMetrics()` writes actor and placement-group usage counters to shared storage, and a passive GCS (empty tables) would overwrite the leader's counts with zeroes — a GCS-initiated write that RPC gating cannot catch. `PrintDebugState()` keeps running while passive so a standby is not dark. **2. Head-node handover — `gcs_node_manager.{h,cc}`** - `PromoteNodeManager()` replays the head node cached in `passive_local_node_` through the real `HandleRegisterNode` path, so it is persisted, publishes `NODE_ADDED`, and — because head registration marks every alive head dead — retires the stale head hydrated from storage. Without it the cluster reports two live heads after a failover. - `ClearPassiveLocalNode()` → `GetPassiveLocalNode()`: the cache is read, not taken, and released from the registration callback once `alive_nodes_` tracks the node. Taking it up front left the head in neither place while two chained storage writes completed (the stale head's DEAD record, then its own), so the un-gated visibility RPCs reported no live head mid-handover. The member is a `std::optional` — it is a value that may be absent, and nothing hands a pointer to it out past `mutex_`. - `CachePassiveLocalNode()` → `TryHandlePassiveHeadRegistration()`, returning whether the registration was handled. The gated handler used to reply `OK` unconditionally; if promotion landed between its `!is_leader_fn_()` check and the cache write, the node was neither cached nor registered, and the raylet never retries an `OK`. On`false` the handler now falls through to the real `HandleRegisterNode`. **3. `GcsServer::PromoteToLeader()`** - Loads the tables, `HydrateManagers()`, flips `is_leader_`, promotes the node manager, `WriteActiveOnlyKeys()`, `StartMetricsReporting()`. - Order is load-bearing: flipping `is_leader_` earlier serves mutating RPCs against half-loaded state; promoting the node manager earlier registers the local head before the stale one is loaded, leaving two live heads. - `HydrateManagers()` covers every manager, in `DoStart()`'s order, because `GcsNodeManager::Initialize()` no longer notifies the node-added listeners. Relying on that fan-out was wrong twice over: `Postable::Post` enqueues rather than runs inline, so `GcsPlacementGroupManager::Initialize()` scheduled its pending groups against a zero-node resource view, and the previous leader's head reached the listener's metrics branch and took the one-shot `metrics_exporter_initialized_` latch with a remote agent port. Suppressing the fan-out is a no-op for `DoStart()`, where the listener list is still empty at that point. - Guarded on `IsLeader() || promotion_started_` — neither alone is enough, and a second load would hydrate twice (`GcsJobManager` bumps a per-job reference count that would never drop back to zero). - Promotion arriving while `Start()` is parked on the cluster-ID wait just flips `is_leader_`: that wait only ends when a leader writes the ID, and that leader is now us. The continuation then boots active and runs `WriteActiveOnlyKeys()`. **4. Flag wiring — `gcs_server_main.cc`** - Assign `GcsServerConfig::enable_gcs_leader_election` from `RayConfig::ENABLE_GCS_LEADER_ELECTION()` (env `RAY_ENABLE_GCS_LEADER_ELECTION`). Nothing assigned it before, so the passive/promotion paths were unreachable. - Field renamed `ray_leader_elect_enabled` → `enable_gcs_leader_election` (internal struct field only) so the feature greps as one name. - Loud startup `WARNING`: no production caller drives promotion yet, so a lone head with the flag set parks on the cluster-ID wait. Better an explicit warning than something that looks like a hang. The warning goes away once the elector lands. ## Tests ### Unit — `//src/ray/gcs/tests:gcs_node_manager_test` Exercises `GcsNodeManager` in isolation (no server, no Redis), pinning the head-node cache semantics independently of how promotion is driven. | Test | What it guards | | :--- | :--- | | `TestPromoteRegistersCachedHeadAndKillsStaleHead` | The head cached while passive becomes a real alive node on promotion, the stale head is marked dead, and a second promotion registers nothing again. | | `TestPromoteIsNoopWithoutCachedHead` | The default (leader-election-off) path, where nothing was ever cached, must not invent a registration. | | `TestPassiveHeadRegistrationSkipsWhenPromoted` | Registration is async, so this covers the window after promotion but before `alive_nodes_` is populated. The head promotion is registering is reported handled; any other head is not, so the caller registers it instead of dropping it. | | `TestHeadStaysVisibleDuringPromotionHandover` | Mid-handover, with the stale head already retired and the storage write still in flight, CheckAlive and the alive-head query must already answer with the promoted head. | | `TestInitializeDoesNotNotifyNodeAddedListeners` | Initialize() restores the cache without emitting node-added events, which is what lets HydrateManagers() feed the downstream managers itself. | ### `//src/ray/gcs/tests:gcs_leader_gated_handlers_test` Extended `TestNodeRegistrationAndGating`: when the cache reports the registration was not handled, the proxy must fall through to the real handler instead of replying OK. | ### Integration — `//src/ray/gcs/tests:gcs_server_rpc_test` Real `GcsServer` processes against a real Redis over real gRPC. Two heads with leader election enabled is the only topology a production cluster produces, so `GcsLeaderElectionTestBase` starts no GCS of its own and `GcsLeaderElectionTest` adds one promoted leader. | Test | What it guards | | :--- | :--- | | `TestPassiveServerReadiness` | A passive GCS adopts the leader's cluster ID, serves health checks, and reports `is_leader=false` over `CheckAlive`. | | `TestColdStartPromotionBootsWinnerAndLoser` | A cluster coming up for the first time: two candidates park against empty storage writing nothing; promoting one releases its own cluster-ID wait instead of deadlocking, writes the three keys, and thereby unblocks the other, which adopts the same ID and stays passive. | | `TestPromotionActivatesTheServer` | Before promotion a passive GCS cannot see a node the leader persisted and rejects RegisterNode with GcsPassive; after promotion it serves that node from storage, reports its resources through GetAllTotalResources (the resource manager is hydrated, not just the node table), and accepts the same registration. | | `TestPromotionHandsOverTheHeadNode` | The head handover a failover comes down to: the cached local head reaches storage only at promotion, the head it replaces is retired, and exactly one head stays alive. | | `TestPromotionRewritesActiveOnlyKeys` | A promoted GCS updates the GCS pid and autoscaler-v2 flag rather than leaving the previous leader's values. | | `TestPromotionIsIdempotent` | The elector re-invokes `on_started_leading`; both calls are issued from one handler so the second also lands while the first is still loading tables. | ### Manual — the legacy path is untouched No unit test covers `main()`, and the point of this PR is that a normal cluster does not notice it, so the default path was exercised on a real cluster with the flag unset. Both entry points were checked because `ray.init()` and `ray start --head` reach `gcs_server_main.cc` differently. Via `ray.init()`: - the flag defaults to `False` and the env var is unset - tasks and actors run normally - one alive node, which is the driver's node; reading the GCS node table directly shows exactly one alive `is_head_node` - `gcs_pid` and `__autoscaler_v2_enabled` are both present in the KV store at startup, confirming the extracted writes still happen inline - `is_gcs_leader()` and `is_gcs_leader_local()` both return `True` - `gcs_server.out` contains no leader-election lines at all and logs normal cluster-ID generation - clean `ray.shutdown()` Via `ray start --head`: the cluster starts, `ray status` reports the node active with full resources, the GCS log again shows no leader-election lines, and `ray stop` leaves no stray processes. With the flag **on**, the same binary logs the experimental warning, starts passive, and parks on the cluster-ID wait without ever writing one, because the leader election lib has not been integrated yet. ## Related issues ray-project#63643 ## Additional information > Optional: Add implementation details, API changes, usage examples, screenshots, etc. --------- Signed-off-by: Yuchen Zhou <[email protected]>

Description
Third slice of the Phase 2 split of #64422. Earlier slices landed the passive interface (proto /
StatusCode::GcsPassive/ config / client) and the server-side RPC gating. This PR focuses on the passive GCS lifecycle including cold start andpromotion. Everything is behind
RAY_ENABLE_GCS_LEADER_ELECTION, default off.Please note that the gcs has not connected to the elector. There is no caller to trigger the promotion yet.
Key changes
1. Passive boot —
gcs_server.{h,cc}GetOrGenerateClusterId()is restructured into three explicit branches; the new one is "no cluster ID yet and passive" → wait for the leader to write it (1s retry, rate-limited log) instead of minting one.Put()s are extracted intoWriteGcsPid()/WriteAutoscalerV2Flag(), still called inline when leader election is off.RecordMetrics()and the startup metrics-exporter init move intoStartMetricsReporting(), now active-only:RecordMetrics()writes actor and placement-group usage counters to shared storage, and a passive GCS (emptytables) would overwrite the leader's counts with zeroes — a GCS-initiated write that RPC gating cannot catch.
PrintDebugState()keeps running while passive so a standby is not dark.2. Head-node handover —
gcs_node_manager.{h,cc}PromoteNodeManager()replays the head node cached inpassive_local_node_through the realHandleRegisterNodepath, so it is persisted, publishesNODE_ADDED, and — because head registration marks every alive head dead — retires the stale head hydrated from storage. Without it the cluster reports two live heads after a failover.ClearPassiveLocalNode()→GetPassiveLocalNode(): the cache is read, not taken, and released from the registration callback oncealive_nodes_tracks the node. Taking it up front left the head in neither place while two chained storage writes completed (the stale head's DEAD record, then its own), so the un-gated visibility RPCs reported no live head mid-handover. The member is astd::optional— it is a value that may be absent, and nothing hands a pointer to it out pastmutex_.CachePassiveLocalNode()→TryHandlePassiveHeadRegistration(), returning whether the registration was handled. The gated handler used to replyOKunconditionally; if promotion landed between its!is_leader_fn_()check and the cache write, the node was neither cached nor registered, and the raylet never retries anOK. Onfalsethe handler now falls through to the realHandleRegisterNode.3.
GcsServer::PromoteToLeader()HydrateManagers(), flipsis_leader_, promotes the node manager,WriteActiveOnlyKeys(),StartMetricsReporting().is_leader_earlier serves mutating RPCs against half-loaded state; promoting the node manager earlier registers the local head before the stale one is loaded, leaving two live heads.HydrateManagers()covers every manager, inDoStart()'s order, becauseGcsNodeManager::Initialize()no longer notifies the node-added listeners. Relying on that fan-out was wrong twice over:Postable::Postenqueues rather than runs inline, soGcsPlacementGroupManager::Initialize()scheduled its pending groups against a zero-node resource view, and the previous leader's head reached the listener's metrics branch and took the one-shotmetrics_exporter_initialized_latch with a remote agent port. Suppressing the fan-out is a no-op forDoStart(), where the listener list is still empty at that point.IsLeader() || promotion_started_— neither alone is enough, and a second load would hydrate twice (GcsJobManagerbumps a per-job reference count that would never drop back to zero).Start()is parked on the cluster-ID wait just flipsis_leader_: that wait only ends when a leader writes the ID, and that leader is now us. The continuation then boots active and runsWriteActiveOnlyKeys().4. Flag wiring —
gcs_server_main.ccGcsServerConfig::enable_gcs_leader_electionfromRayConfig::ENABLE_GCS_LEADER_ELECTION()(envRAY_ENABLE_GCS_LEADER_ELECTION). Nothing assigned it before, so the passive/promotion paths were unreachable.ray_leader_elect_enabled→enable_gcs_leader_election(internal struct field only) so the feature greps as one name.WARNING: no production caller drives promotion yet, so a lone head with the flag set parks on the cluster-ID wait. Better an explicit warning than something that looks like a hang. The warning goes away once the elector lands.Tests
Unit —
//src/ray/gcs/tests:gcs_node_manager_testExercises
GcsNodeManagerin isolation (no server, no Redis), pinning the head-node cache semantics independently of how promotion is driven.TestPromoteRegistersCachedHeadAndKillsStaleHeadTestPromoteIsNoopWithoutCachedHeadTestPassiveHeadRegistrationSkipsWhenPromotedalive_nodes_is populated. The head promotion is registering is reported handled; any other head is not, so the caller registers it instead of dropping it.TestHeadStaysVisibleDuringPromotionHandoverTestInitializeDoesNotNotifyNodeAddedListeners//src/ray/gcs/tests:gcs_leader_gated_handlers_testExtended
TestNodeRegistrationAndGating: when the cache reports the registration was not handled, the proxy must fall through to the real handler instead of replying OK. |Integration —
//src/ray/gcs/tests:gcs_server_rpc_testReal
GcsServerprocesses against a real Redis over real gRPC. Two heads with leader election enabled is the only topology a production cluster produces, soGcsLeaderElectionTestBasestarts no GCS of its own andGcsLeaderElectionTestadds one promoted leader.TestPassiveServerReadinessis_leader=falseoverCheckAlive.TestColdStartPromotionBootsWinnerAndLoserTestPromotionActivatesTheServerTestPromotionHandsOverTheHeadNodeTestPromotionRewritesActiveOnlyKeysTestPromotionIsIdempotenton_started_leading; both calls are issued from one handler so the second also lands while the first is still loading tables.Manual — the legacy path is untouched
No unit test covers
main(), and the point of this PR is that a normal cluster does not notice it, so the default path was exercised on a real cluster with the flag unset. Both entry points were checked becauseray.init()andray start --headreachgcs_server_main.ccdifferently.Via
ray.init():Falseand the env var is unsetis_head_nodegcs_pidand__autoscaler_v2_enabledare both present in the KV store at startup, confirming the extracted writes still happen inlineis_gcs_leader()andis_gcs_leader_local()both returnTruegcs_server.outcontains no leader-election lines at all and logs normal cluster-ID generationray.shutdown()Via
ray start --head: the cluster starts,ray statusreports the node active with full resources, the GCS log again shows no leader-election lines, andray stopleaves no stray processes.With the flag on, the same binary logs the experimental warning, starts passive, and parks on the cluster-ID wait without ever writing one, because the leader election lib has not been integrated yet.
Related issues
#63643
Additional information