[Bug] Occasional bad byte in gyro value on Technic Hub #1026
When we become nonstationary, it is normally because the (raw) sensor values change beyond a threshold. For example, if I touch the hub with the configuration described below, I get an expected result such as:
# gyro xyz, accl xyz, 16 bit int
-2 11 3 39 3 4308 # Stationary value we compare to
-3 9 3 60 46 4189 # This exceeds the 100 threshold on Z, so nonstationary
But sometimes when it is sitting perfectly still, we see:
-2 5 3 41 0 4248
253 9 0 34 -16 4244 # <---- The 253 should be approximately -2
Could we be reading the frame while it is being updated?
Reproduce:
Run a program like this on the Technic hub while it sits flat on the table:
Activity
laurensvalk commentedon Apr 4, 2023
I think I have identified the issue.
When we become nonstationary, it is normally because the (raw) sensor values change beyond a threshold. For example, if I touch the hub with the configuration described below, I get an expected result such as:
But sometimes when it is sitting perfectly still, we see:
Could we be reading the frame while it is being updated?
Reproduce:
Run a program like this on the Technic hub while it sits flat on the table:
Run a modified firmware to add a debug print when the hub first becomes non stationary:
laurensvalk commentedon Apr 4, 2023
Reverting pybricks/pybricks-micropython@121c4db seems to fix it.
The data sheet does recommend to keep this on.
Is there a downside to keeping this on? Could we occasionally miss an update this way?
pbio/drv/imu_lsm6ds3tr_c_stm32: Revert dropping block update.
pbio/drv/imu_lsm6ds3tr_c_stm32: Revert dropping block update.