Skip to content

bcache: Fix btree_read_average_duration_seconds unit - #3828

Merged
SuperQ merged 2 commits into
prometheus:masterfrom
Finomosec:bcache-btree-read-duration-unit
Sep 25, 2026
Merged

SuperQ merged 2 commits into
prometheus:masterfrom
Finomosec:bcache-btree-read-duration-unit

Conversation

@Finomosec

Copy link
Copy Markdown
Contributor

@SuperQ

node_bcache_btree_read_average_duration_seconds is 1000x too small. The collector reads internal/btree_read_average_duration_us, which the kernel reports in microseconds (sysfs_print_time_stats(&c->btree_read_time, btree_read, ms, us) in drivers/md/bcache/sysfs.c), but scales it with 1e-9 as if it were nanoseconds. The procfs field is named BtreeReadAverageDurationNanoSeconds, which is probably where the mix-up came from.

Example from a live system: sysfs shows 3660 (3.66 ms), the metric reports 3.66e-06 (3.66 µs).

This scales by 1e-6 instead and updates the e2e fixtures (1305 µs → 0.001305 s). Renaming the misleading procfs field would be a separate change in prometheus/procfs.

The kernel reports btree_read_average_duration_us in microseconds, but the
value was scaled as nanoseconds, making the metric 1000x too small.

Signed-off-by: Finomosec <[email protected]>

@SuperQ SuperQ left a comment

Copy link
Copy Markdown
Member

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Thanks!

I also created prometheus/procfs#871 to fix the upstream library struct field.

@SuperQ
SuperQ merged commit 60ce437 into prometheus:master Sep 25, 2026
17 checks passed
@SuperQ SuperQ mentioned this pull request Nov 18, 2026
SuperQ added a commit that referenced this pull request Nov 18, 2026
The behavior of `node_cpu_frequency_hertz` has changed. There are two different sources
of data for this metric. One from the `cpu` collector, one from the `cpufreq` collector.
Due to historical feature migrations the `cpufreq` collector shares the same subsystem
as the `cpu` collector. This caused conflicting data behavior. An attempt to fix this
was introduced in #3318. This behavior has been reverted to the previous behavior in #3795.

A new flag (`--collector.cpufreq.enable-cpufreq-prefix`) has been introduced that gives
the `cpufreq` a dedicated metric name subsystem (`node_cpufreq_...`). This will likely
be the default in v2.

* [CHANGE] netstat: Use procfs parsers for netstat, snmp and snmp6 #3796
* [CHANGE] edac: Fix no data results #3863
* [CHANGE] nvme: Deprecate metric nvme_namespace_capacity_bytes #3899
* [FEATURE] Add tainted collector for /proc/sys/kernel/tainted #3745
* [FEATURE] Add resctrl collector #3797
* [ENHANCEMENT] netstat: Add new FreeBSD metrics #3334
* [ENHANCEMENT] Add `chip` label to DRM metrics #3572
* [ENHANCEMENT] diskstats: add device-mapper backing device info metric #3676
* [ENHANCEMENT] textfile: support UTF-8 metric and label names #3729
* [ENHANCEMENT] ksmd: add general_profit metric #3778 #3894
* [BUGFIX] edac: Fix printf-style formatting in slog call #3759
* [BUGFIX] fibre_channel: fix crash when attempting to dereference invalid counters #3573
* [BUGFIX] thermal: Fix collecting Darwin temperatures without CPU power status #3767
* [BUGFIX] fibrechannel: Fix for ppc64le #3769
* [BUGFIX] cpu: Revert dup cpu frequency, add node_cpufreq flag #3795
* [BUGFIX] infiniband: skip sysfs reads for excluded devices #3824
* [BUGFIX] bcache: Fix btree_read_average_duration_seconds unit #3828

Signed-off-by: Ben Kochie <[email protected]>
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Labels

None yet

Projects

None yet

Development

Successfully merging this pull request may close these issues.

2 participants