Skip to content

feat(redis): fault injection in pub/sub and MONITOR push streams - #17

Merged
pingedbrain merged 1 commit into
mainfrom
feat/redis-push-stream-injection
Oct 28, 2026
Merged

pingedbrain merged 1 commit into
mainfrom
feat/redis-push-stream-injection

Conversation

@pingedbrain

Copy link
Copy Markdown
Owner

What

After a forwarded SUBSCRIBE/PSUBSCRIBE/SSUBSCRIBE/MONITOR, redis mode spliced the sockets and stopped deciding — pushes were pure passthrough. Now the upstream→client direction decides per pushed frame while c→u stays a raw splice.

  • _push_facts maps message frames (message/pmessage/smessage, RESP2 * or RESP3 >) to operation: = frame head, resource: = channel; MONITOR +lines decide as operation: monitor, gated on the +<ts> [<db> <cli>] shape so +PONG/+OK mid-mode replies never get decided.
  • Effects in push mode: latency/timeout_ms delay delivery, timeout: true latches the stream dead, reset and cut_reply: {after_messages: N} abort the link, error: writes a -ERR frame in the message's place, and the new drop: true rule fault swallows the push.
  • Subscribe acks, RESP3 | attribute frames and interleaved command replies relay un-decided. Every decided push emits a FiredEvent — same observability as the command path.
  • drop wired through the rule DSL: from_dict/to_dict/describe.

Closes #16. Part of #6 — subscribe/stream-mode injection. Next on #6: TLS termination.

Why

#6 tracks extracting the protocol-agnostic core across wire transports; stream-mode injection is the remaining functional gap for redis mode (pub/sub + MONITOR are the only un-decidable traffic left).

How verified

  • 8 new integration tests in tests/test_resp_server.py (fake upstream gained a MONITOR push mode): drop, error-replaces-push, reset mid-stream, cut_reply.after_messages, per-push latency, channel-selective resource: matching, MONITOR passthrough + drop with +PONG shape disambiguation.
  • pytest: 1690 passed, 2 skipped.
  • ruff check src/ tests/: clean. pyright: 0 errors.

After a forwarded SUBSCRIBE/PSUBSCRIBE/SSUBSCRIBE/MONITOR the proxy used
to splice the sockets and stop deciding. The upstream->client direction
now decides per pushed frame instead:

- `_push_facts` maps pub/sub message arrays and RESP3 `>` pushes to
  `operation:` = frame head and `resource:` = channel; MONITOR `+lines`
  decide as `operation: monitor`, gated on the `+<ts> [<db> <cli>]`
  shape so mid-mode command replies (+PONG/+OK) stay un-decided.
- Effects in push mode: latency/timeout_ms delay delivery, `timeout:
  true` latches the stream dead, `reset` and `cut_reply.after_messages`
  abort the link, `error:` writes a -ERR frame in the message's place,
  and the new `drop: true` fault swallows the push.
- c->u stays a raw splice; acks and non-message frames relay un-decided.
- Every decided push emits a FiredEvent — same observability as the
  command path.

Closes #16. Part of #6 (subscribe/stream-mode injection).
@pingedbrain
pingedbrain merged commit f6ec4e6 into main Oct 28, 2026
5 checks passed
@pingedbrain
pingedbrain deleted the feat/redis-push-stream-injection branch October 28, 2026 02:03