Documentation inconsistency: 2-drive EC:1 works, but server reference says minimum 4 drives #197

Closed

Description

@tiredenzo

Documentation inconsistency: 2-drive EC:1 works, but server reference says minimum 4 drives

Summary

There appears to be a documentation inconsistency regarding the minimum number of drives required for erasure coding.

The Silo Server reference currently states:

The minio server process requires at least 4 drives or directories to enable erasure coding.

However, the Silo storage-class documentation explicitly lists:

Erasure Set Size | Default Parity -- | -- 1 | EC:0 2–3 | EC:1 4–5 | EC:2

I tested the current Silo release with two physical drives, and a 2-drive EC:1 erasure set works successfully.

Environment

Silo version:

RELEASE.2026-09-03T13-18-01Z

Single server with two independent physical HDDs.

Each HDD has a dedicated XFS partition:

/dev/sda3 -> /mnt/minio-disk1
/dev/sdb3 -> /mnt/minio-disk2

Configuration:

MINIO_VOLUMES="/mnt/minio-disk1 /mnt/minio-disk2"
MINIO_STORAGE_CLASS_STANDARD="EC:1"
MINIO_OPTS="--console-address :9001"

Actual behavior

Silo starts successfully and initializes a two-drive erasure set:

INFO: Formatting 1st pool, 1 set(s), 2 drives per set.

The server starts normally and both readiness checks succeed:

ready: ok (200)
cluster: ok (200)

mcli admin info confirms the topology:

Drives: 2/2 OK
Pool: 1

Pool Drives Usage Erasure stripe size Erasure sets
1st 1.9% (total: 5.0 TiB) 2 1

2 drives online, 0 drives offline, EC:1

Object operations also work correctly:

  • bucket creation

  • object upload

  • object listing

  • object download/read

all succeeded.

MinIO behavior/documentation

This configuration was also documented as functional by upstream MinIO.

MinIO documentation describes erasure coding sets as supporting 2 to 16 drives.

The MinIO limits documentation also specifies:

Minimum number of drives per server when server count is 1: 02

and MinIO's distributed documentation states that the minimum number of drives required is 2, the same as the minimum for erasure coding, and that erasure coding automatically activates at that topology.

Since Silo is a maintained MinIO fork and preserves the MinIO storage model and compatibility, the working two-drive behavior in Silo appears consistent with the underlying MinIO behavior.

Documentation conflict

So currently there are three pieces of evidence supporting two-drive EC:

  1. Silo's storage-class documentation defines 2–3 drives as EC:1.

  2. The current Silo binary successfully creates and operates a 2-drive EC:1 erasure set.

  3. Upstream MinIO documentation explicitly documents 2-drive erasure sets / a 2-drive minimum.

But the Silo Server reference says:

The minio server process requires at least 4 drives or directories to enable erasure coding.

Suggested clarification

Could you please clarify whether a single-node, two-physical-drive EC:1 deployment is officially supported by Silo?

If it is supported, I suggest updating the Server reference to distinguish between:

  • minimum technically supported erasure set: 2 drives

  • recommended production topology: potentially 4+ drives/nodes depending on the desired availability guarantees

That distinction would avoid implying that a two-drive erasure set cannot be created, when the current Silo release demonstrably supports it.

Thanks.

Activity

  1. added
    bug
    documentation
    on Sep 15, 2026
  2. self-assigned this
    on Sep 15, 2026
  3. added theissue type on Sep 15, 2026
  4. Vonng commented on Sep 16, 2026

    @Vonng
    Member

    Rechecked against the published 20260916 release and public documentation: this inconsistency is not resolved. The public Server reference still says that erasure coding requires at least four drives, while the storage-class/reference material and the reported runtime behavior describe a two-drive EC:1 set.

    The 20260916 release does not establish a new production-topology support commitment. Keeping this open until the source/reference wording is merged and published with an explicit distinction between the technical minimum and the recommended failure-domain topology.

  5. yupoet commented on Sep 26, 2026

    @yupoet

    Cross-checking: content/reference/minio-server/_index.md on the website repo main branch was corrected on 2026-09-17 ("docs: correct erasure-set quorum rules and document two-drive EC:1") and now states erasure coding works with a minimum of 2 drives defaulting to EC:1, consistent with the storage-class reference and the reported runtime behavior.

    I could not find any remaining "at least 4 drives" wording in either repo via code search ("at least 4", "at least four", "minimum of 4"). If the only pending step is publishing the site, this may be ready to close once that ships.

  6. closed this as completedby moving to Done in Siloon Sep 26, 2026