Using CC1101 receiver recording raw pulse durations of fan remote, sequences can be decoded as they are fixed. The only security feature is a 16 bit id.
- Period for 1 bit is about 1200 microseconds.
- Zero is high short low long
- One is high long low short
FAN_POWER : 0001 0001
FAN_SPEED_1 : 0000 0010
FAN_SPEED_2 : 0000 0011
FAN_SPEED_3 : 0000 0100
FAN_SPEED_4 : 0000 0101
FAN_SPEED_5 : 0000 0110
FAN_SPEED_6 : 0000 0111
FAN_SPEED_MIXED : 0000 1111
FAN_TIMER_1H : 0000 0000
FAN_TIMER_4H : 0000 0001
FAN_DIR : 0000 1001
FAN_TIMER_8H : 0000 1110
LIGHT_BRIGHTEN : 0000 1100
LIGHT_POWER : 0000 1010
LIGHT_DIM : 0000 1101
Format of a payload:
- 16 bit command
- single byte repeated twice
- 16 bit fan identification