Skip to content

About

Reverse engineering of the Fanco Flow DC ceiling fan remote protocol.

Topics

Resources

Stars

0 stars

Watchers

0 watching

Forks

Latest commit

 

History

11 Commits

Folders and files

NameName
Last commit message
Last commit date
 
 
 
 
 
 
 
 
 
 
 
 

Repository files navigation

Fanco Flow DC Ceiling Fan

Using CC1101 receiver recording raw pulse durations of fan remote, sequences can be decoded as they are fixed. The only security feature is a 16 bit id.

  • Period for 1 bit is about 1200 microseconds.
  • Zero is high short low long
  • One is high long low short
FAN_POWER       : 0001 0001
FAN_SPEED_1     : 0000 0010
FAN_SPEED_2     : 0000 0011
FAN_SPEED_3     : 0000 0100
FAN_SPEED_4     : 0000 0101
FAN_SPEED_5     : 0000 0110
FAN_SPEED_6     : 0000 0111
FAN_SPEED_MIXED : 0000 1111
FAN_TIMER_1H    : 0000 0000
FAN_TIMER_4H    : 0000 0001
FAN_DIR         : 0000 1001
FAN_TIMER_8H    : 0000 1110
LIGHT_BRIGHTEN  : 0000 1100
LIGHT_POWER     : 0000 1010
LIGHT_DIM       : 0000 1101

Format of a payload:

  • 16 bit command
    • single byte repeated twice