--oci-layout-path accepts custom header flags that --oci-layout rejects #2298
--oci-layout rejects custom header flags, but --oci-layout-path (and --from-oci-layout-path / --to-oci-layout-path) accepts them and ignores them:
$ oras manifest fetch --oci-layout layout:v1 -H foo:bar
Error: custom header flags cannot be used on an OCI image layout target
$ oras manifest fetch v1 --oci-layout-path layout -H foo:bar
(no error, the header is not used)
In Target.Parse (cmd/oras/internal/option/target.go) the check is only in the case target.IsOCILayout: branch. The case target.Path != "": branch also sets the target type to oci-layout but has no such check.
I found this by reading the code and checked it with a unit test on Target.Parse (the e2e test for this error only covers --oci-layout), not by running the CLI.
What did you expect to happen?
The same error for both ways of selecting an OCI image layout target.
How can we reproduce it?
Pass a header flag together with --oci-layout-path, for example oras manifest fetch v1 --oci-layout-path layout -H foo:bar, or run the unit test in the linked PR.