Starting from OpenPI 0.9.0 pulled from source, the very first session prints a startup warning whose text covers three unrelated situations in one line. When the only real diagnostic is a missing top-level configVersion on a previously-written my-pi-setup.json, the warning still tells the user to "run /openpi-setup for details" and points at "unknown fields", even though there are no unknown fields and the file loads correctly.
Environment
- OpenPI: from source checkout (
@tt-a1i/[email protected]) - Pi:
@earendil-works/pi-coding-agent(installed under workbuddy-managed Node) - Node:
v22.22.2 - Config file:
~/.pi/agent/my-pi-setup.json, written by an earlier OpenPI version (no top-levelconfigVersion) - Fields present in the file (all recognised by
setupShape):suggestions,workflows,ui,postEdit,subagents, plus nestedui.showHeader,ui.customFooter,ui.footerStyle,ui.footerLines,ui.footerItems,ui.subagentResultDisplay,ui.bashToolDisplay,ui.fileMutationDisplay, etc.
Reproduction
-
Have an older OpenPI (or pre-
configVersion) writemy-pi-setup.jsonwithout a top-levelconfigVersion. -
Pull the current source (
main), restart Pi (or run/reload). -
On
session_start, the user immediately sees:OpenPI configuration loaded with warnings (legacy format or unknown fields). The file is unchanged. Run /openpi-setup for details.
Actual diagnostic
Calling the built-in inspectSetupConfig() / formatSetupDiagnostics() directly returns:
Configuration path: /Users/<user>/.pi/agent/my-pi-setup.json
Configuration source: disk
Configuration version: legacy (unversioned); supported: 1
Configuration writes: allowed
warning: "configVersion" — Legacy unversioned document; migration occurs on explicit save
writable: true
- The diagnostics array contains exactly one warning.
- The only
pathisconfigVersion. - No unknown fields are reported; every key in the file is recognised by
setupShape.
Root cause
extensions/setup/index.ts:244-255 treats any warning as the same generic notification:
pi.on("session_start", (_event, ctx) => {
resetEpisode();
if (!ctx.hasUI) return;
const inspected = inspectSetupConfig();
if (inspected.diagnostics.length === 0) return;
ctx.ui.notify(
inspected.writable
? "OpenPI configuration loaded with warnings (legacy format or unknown fields). The file is unchanged. Run /openpi-setup for details."
: "OpenPI could not load the saved configuration; safe defaults are in use and configuration writes are blocked. The file is unchanged. Run /openpi-setup for diagnostics and recovery guidance.",
inspected.writable ? "warning" : "error",
);
});Three categories of warning are folded into one message:
| Category | Reality today | Trigger | What the user should do |
|---|---|---|---|
| Legacy unversioned | warning, missing configVersion |
pre-configVersion file |
Nothing — explicit save will migrate it |
| Unknown field | key preserved, warned | schema-external key | Decide: remove key or accept |
| Real error / corrupted config | reads blocked | malformed JSON, IO error, unsupported version | Run /openpi-setup for diagnostics |
The wording "legacy format or unknown fields" simultaneously suggests both, even though their nature, fix path, and risk are completely different. In the legacy-only case there is no second problem to investigate.
Why this is a bug
- Misleading: in a pure legacy scenario the user is told to suspect unknown fields, and is pushed to
/openpi-setupto debug a non-problem. - Overly noisy:
writable: truelegacy load is already a safe, documented state.SETUP.md:43("Unversioned documents migrate only on an explicit save") makes it an intentional compatibility mode, not a failure. Repeated warnings on every startup after upgrading from an older OpenPI do not help the user — they tell them to redo/openpi-setupfor a file that is already valid and already loaded. - Lacks precise diagnosis: the warning carries no
path. The user has to run/openpi-setupto learn what is actually wrong. For a pure legacy case this is wasted effort.
Suggested direction (minimum-change)
The fix should make sure the upgrade-from-older-openpi experience is silent when the only diagnostic is a missing configVersion on a writable: true file, because the existing design already treats that state as safe and migration-only. Concretely:
- In
extensions/setup/index.ts'ssession_starthandler, branch on the diagnostics instead of treating them as one bucket. Only notify when at least one entry is not a pure-legacy case (i.e. there is an unknown field, a read error, or an unsupported version). - When notifying, change the text so it no longer conflates "legacy format" with "unknown fields" — describe the actual category and include the relevant
pathfrom the diagnostic entry (theinspectSetupConfigoutput already carries it). - Do not auto-write the file on startup. The migration remains opt-in via
/openpi-setup, per the contract in setup: 配置诊断与 fail-closed 回滚,不新增第二条配置入口 #498 andSETUP.md:43. - Keep the error branch for the truly unreadable / unsupported-version case (current second message) intact.
A user upgrading from any pre-configVersion OpenPI should be able to keep their existing my-pi-setup.json and see no warning until they explicitly choose to migrate.
References
- Source:
extensions/setup/index.ts:244-255(session_starthandler). - Config contract & 404:
SETUP.md:43— Unversioned documents migrate only on an explicit save. - Design background: setup: 配置诊断与 fail-closed 回滚,不新增第二条配置入口 #498 (closed) — setup: 配置诊断与 fail-closed 回滚,不新增第二条配置入口. This issue is not a regression of setup: 配置诊断与 fail-closed 回滚,不新增第二条配置入口 #498; it reports that the warning text introduced around setup: 配置诊断与 fail-closed 回滚,不新增第二条配置入口 #498 still needs tightening to honour the legacy-is-safe design.
- Diagnostic entrypoint used in reproduction:
inspectSetupConfig()/formatSetupDiagnostics()in the sameextensions/setupextension.
Activity
samsen3 commentedon Sep 28, 2026
我来认领这个问题。
本 PR 我会尽量保持最小改动,只动
extensions/setup/index.ts中session_start的通知分支:configVersion、writable: true的 legacy 场景:不再弹警告(升级后用户不需要重跑/openpi-setup,配置照常生效,文件保持不变)。path一并带上。明确不做的:
inspectSetupConfig/ diagnostics schema;setup-config.ts的 fail-closed 与写入语义(属于 setup: 配置诊断与 fail-closed 回滚,不新增第二条配置入口 #498 已定下来的范围);configVersion: 1,迁移仍按SETUP.md:43保持 opt-in。测试会在
tests/extensions/setup/加几条:legacy-only writable → 不通知;legacy + unknown field → 通知且文案点名 unknown field;corrupted/unsupported → 维持原错误分支。627150795 commentedon Sep 28, 2026
我来处理这个问题,范围限定在
extensions/setup/index.ts的session_start诊断分支:仅当唯一诊断是可写旧配置缺少configVersion时不再重复提示;未知字段、读取错误和不支持版本继续显示准确类别及路径。不在启动时写回配置,并补充最小回归测试。