Repository navigation
Description
Codex App version
Windows package OpenAI.Codex 26.1013.4894.0 (x64).
Bundled backend reports codex-cli 0.163.0-alpha.10.2.
Platform
Windows 11 Home, OS version 10.0.26200, build 26200, x64. App UI language: Traditional Chinese.
Problem
Manually choosing Run now for an existing scheduled automation intermittently fails with this Desktop toast:
Unable to start scheduled task
Timed out waiting for MCP response to configRequirements/read
The reporter repeatedly has to fully quit and reopen Codex to make manual execution work again. Recovery after restarting is user-observed; I did not terminate/restart the app as part of this diagnostic collection.
The screenshot shows the automation paused, with Resume, Run now, and Edit still offered. The failure is an internal RPC timeout rather than an actionable explanation of whether that manual invocation can start.
Steps to reproduce
- Keep Codex Desktop open and use existing tasks/automations normally.
- Open an existing automation's menu and choose Run now.
- In the affected state, observe the
configRequirements/readtimeout toast. - Fully quit/reopen Codex and retry the same manual invocation; the reporter observes normal behavior returning temporarily.
- The problem recurs after further use.
The trigger is intermittent; there is no deterministic minimal reproducer yet. Multiple tasks were present. Concurrency may be relevant, but is not established as the cause.
Sanitized local evidence
The following are selected fields from actual Desktop logs on 2026-10-20 UTC, with request IDs, conversation IDs, project names, automation IDs, local paths and task content omitted. These are excerpts from the day's incidents, not a claim that the screenshot click has an exact matched log timestamp.
Earlier instance:
00:19:22.060Z AppServerConnection response_routed
method=configRequirements/read durationMs=133886 errorCode=null
00:20:56.152Z electron-message-handler Request failed
method=configRequirements/read durationMs=30016
code=-32603
message="Timed out waiting for MCP response to configRequirements/read"
pendingCountAfter=24 queueWaitMs=0 source=config
00:21:30.360Z AppServerConnection response_orphaned
requestId=configRequirements/read:<redacted>
transportKind=stdio hasError=false
00:21:30.364Z electron-message-handler
No promise for request ID id=configRequirements/read:<redacted>
Subsequent Desktop instance (launch logged at 01:25:18Z), same installed version:
01:25:22.947Z AppServerConnection response_routed
method=configRequirements/read durationMs=89 errorCode=null
01:27:33.416Z AppServerConnection response_routed
method=configRequirements/read durationMs=5 errorCode=null
01:31:03.473Z AppServerConnection app_server_client_request_queue_rejected
method=configRequirements/read priority=background reason=queue-expired
inFlightRequestCount=4
queuedBackgroundRequestCount=7 queuedInteractiveRequestCount=63
queuedCriticalRequestCount=0 queueWaitMs=30001 source=config
01:31:37.506Z AppServerConnection app_server_client_request_queue_rejected
method=configRequirements/read priority=background reason=queue-expired
inFlightRequestCount=4
queuedBackgroundRequestCount=11 queuedInteractiveRequestCount=64
queuedCriticalRequestCount=0 queueWaitMs=30015 source=config
02:37:36.715Z electron-message-handler Request failed
method=configRequirements/read durationMs=30003
code=-32603
message="Timed out waiting for MCP response to configRequirements/read"
02:39:13.781Z electron-message-handler
Failed to load config requirements
errorCode=-32603
errorMessage="Timed out waiting for MCP response to configRequirements/read"
03:09:43.394Z automations
Failed to load models for automation run
automationId=<redacted>
errorMessage="Timed out waiting for MCP response to model/list"
Expected behavior
Manual invocation should either start, or show an actionable admission error. If Desktop's app-server request/transport state becomes unresponsive, it should recover without requiring a full app restart and without silently starting duplicate automation runs.
Assessment and related issue
This appears related to Desktop/app-server request queuing, response lifetime or connection recovery, based on queued request expiry and orphaned late responses. The exact root cause is not confirmed. The evidence does not identify a failing third-party MCP plugin, a managed-policy refusal, or a particular user automation script.
Possibly related: #38385 (Windows Desktop app-server stalls and restart recovery). This report adds the automation Run now failure on package 26.1013.4894.0. The excerpts here show inFlightRequestCount=4; I am not claiming the six-slot saturation described there was proven in this occurrence.
No raw session logs, screenshots containing private task names, credentials, model settings, repository content or conversation transcripts are included.
Activity
github-actions commentedon Oct 20, 2026
Potential duplicates detected. Please review them and close your issue if it is a duplicate.
Powered by Codex Action