Skip to content

[Windows desktop] Follow-up Send disabled after first turn, persists on 26.917.8451.0 (CLI works) #47716

Done

Description

@lingfenglxz

Summary

For more than a week, the Windows Codex desktop app has been largely unusable for follow-up messages. A new conversation may accept its first message, but after the assistant finishes, typing another message leaves Send disabled/gray. Existing completed conversations behave similarly. The same conversation can still be continued from the Codex CLI. The issue persists after updating the desktop package to 26.917.8451.0.

Environment

  • Windows 11 Pro x64, OS build 26300
  • Codex desktop package: 26.917.8451.0 (previously reproduced on 26.917.6896.0)
  • Standalone Codex CLI: 0.156.1
  • Desktop-bundled app-server binary reports: codex-cli 0.155.0-alpha.16.3

Steps to reproduce

  1. Open Codex desktop on Windows and open a completed conversation, or create a conversation and send its first message.
  2. Wait for the assistant response to finish.
  3. Type a follow-up message.
  4. Observe that Send is disabled/gray and cannot be clicked.

Expected: The completed conversation accepts follow-up messages.

Actual: The desktop composer cannot send. Continuing the same conversation through the CLI works. Opening Settings and returning did not restore Send.

Timeline and sanitized diagnostics

  • 2026-09-23 morning (local time), package 26.917.6896.0: A failing desktop session logged 22 configRequirements/read requests with no transport error, but no turn-start config resolved or method=turn/start.
  • 2026-09-23 17:51 (local), same package 26.917.6896.0: A new desktop session temporarily worked without updating the app. It logged 21 configRequirements/read requests, then 3 turn-start config resolved and 3 method=turn/start events.
  • 2026-09-24 at ~09:04 and ~09:15 (local): The failure returned. The 09:04 session logged 13 configRequirements/read requests with no transport error and no turn-start event.
  • 2026-09-24 09:44:57 (local), after updating to 26.917.8451.0: The new desktop process still failed. The session again had roughly 13 configRequirements/read events with errorCode=null, but no turn-start config resolved or method=turn/start. For example:
    2026-09-24T01:45:08.012Z response_routed method=configRequirements/read errorCode=null hadPending=true durationMs=9
    2026-09-24T01:45:08.024Z response_routed method=windowsSandbox/readiness errorCode=null hadPending=true durationMs=19
    

These lines show that the app's main-process routing received RPC responses without a transport error. They do not establish whether the renderer consumed them, nor do they establish the sandbox readiness result. The exact root cause is unconfirmed. The contrast with the working session may help locate why the desktop client does not proceed to turn/start.

An in-app feedback report was also submitted: no-active-thread-01a0d11d-8ed8-71b3-8e2e-3db9f1a33241.

Possibly related reports: #45626, #46584.

Additional client comparison (2026-09-24)

The Chrome browser extension side panel can send messages, including a follow-up in this conversation, while the Windows desktop app has the disabled Send button. Together with the working CLI, this points toward a desktop-client-specific path. The comparison does not identify the exact failing component; the extension and desktop may use different client code or connection paths.