Repository navigation
Description
Environment
- Codex Desktop package:
OpenAI.Codex 26.820.7780.0 - Bundled app server:
codex-cli 0.150.0-alpha.8 - Platform: Windows x64, OS version
10.0.26200(build26200.9168, 25H2) - Task target: Local, projectless workspace
- Shell: PowerShell
- Model in the captured occurrence:
gpt-5.6-sol, reasoning effortxhigh - Approximate occurrence time: 2026-08-26 19:29, UTC+08:00
Task IDs, local paths, account details, and prompt contents are omitted for privacy.
Preconditions
- The user had deleted all conversations visible in the UI before testing.
- Codex Desktop was running normally and could create a new local task.
- No approval dialog was open or pending.
- The first prompt was short plaintext with no attachment.
Deleting the visible conversations did not make the local Codex state empty. A later read-only inspection still found a substantial local thread index. That is an observation and a possible amplifier, not a confirmed cause.
Minimal reproduction
- Open Codex Desktop on Windows.
- Create a new local task.
- Send a short plaintext first message.
- Wait for the assistant response to finish rendering.
- Type a short second plaintext message in the composer.
- Attempt to send it.
Actual result
The second message remains in the composer and cannot be submitted. The Send button stays disabled/grey even though the first turn has already completed.
For the captured occurrence:
- the assistant response was fully generated;
- the rollout transcript ended with an authoritative
task_completeevent; - the task index later reported the task as
idle; - nevertheless, the visible composer remained locked.
This appears to be a Desktop UI / local state synchronization failure. The available evidence does not establish the underlying root cause.
Expected result
After the first turn reaches its terminal completed/idle state:
- the composer should become enabled;
- the second message should produce a new
turn/start; - if state reconciliation fails, the app should show an actionable error and provide a recovery action instead of leaving the composer disabled indefinitely.
Frequency
The user reports that this occurs on the second message in every new task attempted after deleting all visible conversations.
One occurrence was correlated precisely with local logs and the rollout transcript. The report does not claim a fully automated deterministic reproduction.
Captured timeline and logs
The affected task was created at approximately 19:28:54.
19:29:02 first turn_input submitted
19:29:09 assistant message output completed
19:29:10 post-sampling state:
full_context_window_limit_reached=false
token_limit_reached=false
model_needs_follow_up=false
has_pending_input=false
needs_follow_up=false
The rollout was small (16 records, approximately 136 KB) and ended with:
event_msg task_complete
The task index subsequently reported the affected task as idle.
Two transport warnings occurred during startup/turn preparation:
startup websocket prewarm setup failed:
stream disconnected before completion: tls handshake eof
incremental request failed:
websocket reuse properties didn't match
The response still completed after these warnings, so they are included as correlation only and are not claimed as the cause.
At app startup, the local app-server also emitted repeated thread-index reconciliation warnings:
state db list_threads returned stale rollout path
state db discrepancy during list_threads_db: stale_db_path_retained
A read-only local maintenance report found:
active thread rows: 136
active title characters: 3,791,975
active first_user_message characters: 3,792,320
maximum title / first_user_message length: 77,059
titles over configured limit: 114
first_user_message values over configured limit: 113
first_user_message values over 10k characters: 109
metadata repair candidates: 115
active rollout size: 1.781 GB
archived rollout size: 68.178 GB
current log size: 10.6 MB
This metadata/index bloat may increase the likelihood of a renderer or reconciliation failure, but it has not yet been repaired and A/B tested, so it is not a confirmed root cause.
Items already ruled out or localized
- First-turn model/backend failure: ruled out for the captured occurrence; the assistant reply and
task_completewere persisted. - Turn still legitimately active: ruled out by
task_complete, no pending input/follow-up flags, and the lateridletask status. - Context/token exhaustion: the captured log explicitly reports both context and token limits as not reached.
- Approval wait: no approval request was present; the task used a no-approval/full-access profile.
- Oversized current conversation: the affected new task contained only 16 rollout records and was approximately 136 KB.
- Large current log database: the active log database was only approximately 10.6 MB.
- Optional MCP startup failures: unavailable optional MCP servers were omitted for the affected turn and the thread was created with zero dynamic tools. Earlier MCP connection errors therefore do not establish the cause of this composer lock.
Temporary recovery / workarounds
- Fully quitting and relaunching Codex causes the persisted task to be recognized as idle again.
- This is only a partial workaround: the user reports that the same second-message failure returns in new tasks.
- Starting another new task and deleting visible chat history did not resolve the problem.
- A local thread-metadata repair has been proposed but not yet executed, so it should not be treated as a verified workaround.
Possibly related issues
- [Windows App 26.820.7780.0] Second manual message can freeze before turn/start after cross-task message injection #40794 — same app version and a second manual-message freeze, but that report requires cross-task message injection and localizes the failed click before
turn/start. - Thread stays stuck in generating state after interrupted turn; composer remains disabled until local session log is manually completed #14251 — composer remains disabled after an interrupted turn, but that case is missing
task_complete; this occurrence has a valid terminal event. - Windows composer enables before turn completion; immediate follow-up is dropped #32982 — the inverse timing race, where the composer enables before authoritative turn completion.
- Thread navigation/loading slows from unbounded metadata and eager large-history hydration #21211 — unbounded thread metadata and eager history hydration.
- Codex Desktop renderer reload left turn state out of sync and spammed Item not found in turn state #24263 — Desktop renderer/turn-state reconciliation failures.
Sanitized structural logs can be provided if maintainers need additional detail.
Activity
github-actions commentedon Aug 26, 2026
Potential duplicates detected. Please review them and close your issue if it is a duplicate.
Powered by Codex Action
ashjo42 commentedon Aug 28, 2026
Follow-up: clean-profile A/B result and a working recovery path
I completed a clean-profile recovery after filing this issue. The second-message lock no longer reproduces in the clean profile: the app has since accepted second and later messages in long-running local tasks.
What changed
The important step was not merely reinstalling the Windows package. This installation used a custom
CODEX_HOME, so an uninstall/reinstall would otherwise reopen the same persisted state.The recovery procedure was:
CODEX_HOME; create a new empty home.AGENTS.md, keybindings, selected settings, user skills, project mappings, and selected memory summaries.state_5.sqlite,thread_history_1.sqlite, queue database, WAL/SHM files, logs, caches, WebView profile, locks, or old MCP/plugin runtime state.The live personal-profile restore manifest explicitly excluded all session/index databases and runtime security/policy state. The old profile and raw conversations remain preserved; nothing was deleted.
Additional evidence
This gives a useful A/B localization:
task_completeand the indexed task later becameidle.PRAGMA quick_check, so this does not look like ordinary SQLite page corruption. It is still consistent with stale cross-file paths, oversized metadata, invalid derived projection offsets, or renderer/app-server reconciliation state.I also validated a conservative selective-restore procedure in an isolated sandbox:
That sandbox test is evidence that bounded selective recovery is feasible, but it is not evidence that the 10 MiB threshold is the root-cause boundary.
Working user-side workaround
For affected users with a custom
CODEX_HOME, the reliable recovery sequence is currently:This is a recovery procedure, not a confirmed root-cause fix, and it should not be treated as an officially supported database migration.
Possible product-side fixes
task_complete/ serveridlestate should not remain blocked by stale renderer or thread-list state.titleandfirst_user_messagemetadata during ingestion and avoid eagerly hydrating multi-megabyte metadata into thread-list/UI state.CODEX_HOME, and warn before automatically reopening it.The clean-profile A/B makes old persisted local state a much stronger suspect, but it still does not identify one specific table, path, or metadata field as the root cause.
ihsanakel commentedon Aug 28, 2026
Additional regression evidence on current Windows desktop build
I am seeing the same second-turn/composer lock on the current ChatGPT Desktop build powered by Codex & OWL:
26.825.32147Observed update sequence over roughly the last day is useful for A/B comparison:
Current reproduction on
26.825.32147:This behavior was not present in the immediately preceding working update, which makes this look like a regression reintroduced in
26.825.32147or an interaction between that build and persisted local state.No destructive local-state cleanup has been attempted because conversation/session data should be preserved. A normal full app restart is no longer an effective workaround on the current build.
The rapid sequence broken → still broken → fixed → broken again may help narrow the change range. If maintainers want logs or a specific local diagnostic captured from
26.825.32147, I can provide the exact steps/output requested.ihsanakel commentedon Aug 28, 2026
Additional regression evidence from current Windows desktop build:
26.825.32147Observed behavior matches this issue: the first prompt in a new chat/task sends and completes, but the composer/send control then remains stuck/disabled and a second prompt cannot be submitted. Creating a new chat allows one more prompt, after which the problem repeats.
The behavior has changed across several rapid desktop updates since Aug 27:
26.825.32147, the issue returned, and fully quitting/relaunching no longer fixes it.This looks like a regression that was temporarily corrected in an intermediate build and then reintroduced in the current build. No local Codex data, thread database, or project configuration has been deleted or reset, to avoid masking the regression or risking history loss.
A useful maintainer check may be to compare composer/thread terminal-state reconciliation changes between the intermediate build where the issue disappeared and
26.825.32147.stephenchurch-prog commentedon Aug 29, 2026
Update — 29 August 2026: persists on 26.825.5331.0 after two further updates
The same fresh-task failure has recurred on this installation after two further Codex Desktop updates.
Environment
OpenAI.Codex 26.825.5331.0codex-cli 0.151.0-alpha.7.110.0.26200(26200.9168, 25H2)no-active-thread-01a03eb4-7076-7643-b0ba-68bc151b37faFresh-task reproduction
Immediate log correlation
2026-08-29T14:02:33.971Zand completed at14:02:37.328Z.14:05:22Z.turn/startedevent exists for the failed second message.No conversation state for conversation IDerrors, 85ResizeObserver loop completed with undelivered notificationserrors, and 117 response-routing entries withconversationId=null.This rules out one long conversation as a sufficient explanation and shows the defect persists in a brand-new task on the newer build. Repair, Reset, reinstall and cache-isolation attempts were already exhausted and were not repeated. No task IDs, prompt contents, account details, local paths or raw logs are included here.
Please investigate repeat-turn composer enablement and conversation/turn-state reconciliation on the current Windows build. Sanitised structural logs can be supplied if maintainers specify what they need.
reggienichols commentedon Aug 30, 2026
Still reproducible on ChatGPT/Codex Desktop 26.825.41651, released August 28, 2026, on Windows build 10.0.26200.
A new local projectless chat completes its first short message normally, but the second message spins indefinitely.
Feedback ID: 01a0504c-83f0-7902-b751-c25601699bda
johnnygu commentedon Sep 7, 2026
Still reproducible on Windows build
26.901.51231I am still seeing the same second-turn composer lock after updating Codex Desktop.
26.901.5123126.901.22334C:\Users\<user>\.codex), not a custom pathRepro:
I extracted the relevant app-server logs from
logs_2.sqlite. A normal composer-triggered first turn is present (turn_trigger: Some("composer")). During that turn I also saw one recoverable websocket/TLS interruption:Later, when the same thread was torn down, the app-server state reported:
So the backend/thread state can reach a state where there is no active turn, while the desktop composer still remains disabled for the next user message. In the failing UI state, typing the second prompt does not result in a new composer
turn/startreaching the app-server.This looks consistent with a renderer/composer ↔ app-server state reconciliation problem rather than the model still actively running. The issue persists across the update from
26.901.22334to26.901.51231.I have the sanitized
logs_2.sqliteextract and can provide more targeted excerpts if maintainers want a specific thread/request timeline.FVTAL commentedon Sep 14, 2026
The UI never clears streamRole=owner because turn/completed hits the wrong conversation id.
ashjo42 commentedon Sep 14, 2026
September 15 update: Windows 26.908 — stuck codex-home requests identified; targeted retry restores submission
This remains a blocking problem on my workstation. Earlier clean-profile recovery observations in this issue did not establish a durable fix. I now have a captured failure and a controlled recovery on OpenAI.Codex 26.908.4834.0 (desktop log release 26.908.40834, Windows x64).
Observed state, with text actually present in the composer
This particular snapshot was captured while the diagnostic task was running, so the button was labelled Queue. It is evidence of the configuration-preflight blocker, not a claim that this snapshot alone reproduces the original completed-turn scenario. Separately, a resumed older task had completed history with both userMessage and agentMessage items available.
The shared read-only queries below had no data or error and remained pending/fetching:
Configuration-content reads were already successful. No assumption of database corruption was needed.
Controlled recovery in the same running instance
At 2026-09-14 18:09:51 UTC, only these two pending queries were cancelled and refetched. Both immediately received a
fetch-responsewith status 200, and changed to success/idle. Theloading-local-configblocker then disappeared. The previously waiting draft left the input, and I subsequently submitted a new message successfully through the composer.This intervention did not restart the app, modify the installation package/databases/persistent configuration, change paginated history or permissions, or disable browser/computer-use capabilities. The app had been started by the user with a local diagnostic port to inspect its state. This is a session recovery, not yet a verified cold-start or permanent fix.
Installed-client code path
In
app-initial-d9bed9d614d8.js,aQo → iQo → D8derives a loading state whencodex-homehas neither data nor error. Inapp-primary-17b54400f32a.js,Ygr/Xgr/Zgrpropagate this asloading-local-config; button componentn2includesisLoadingin the native disabled condition. ThussubmitDisabled=falsedoes not mean the actual button is enabled.The inspected bridge
sS.post()waits forfetch-responseor abort, with no client hard timeout in that path. The composer queueyvrcan retain a pending submission while configuration is loading and continue it when loading resolves.The initiating failure is still unknown: an internal await, startup ordering, response loss, or window/connection lifecycle could be involved. Current startup logs were empty. This does not prove all historical reports here share the same cause, nor does it establish IAB routing as the cause.
Requested engineering action
Please triage this to the Windows desktop bridge/configuration owner and confirm whether this specific failure path is already tracked. The minimum durable fix should provide:
turn/startmust be reconciled with server state, not blindly retried like a directory read.Please add tests for lost/late configuration responses, cold start, window reload, task switching while waiting, and duplicate-send prevention. A lost response should produce recovery or an actionable error, never a permanently disabled composer.
This comment contains sanitized structural evidence only; no account identifiers, private task IDs, local workspace paths, draft text, or full logs are attached.
Official in-app feedback cross-reference:
no-active-thread-01a0a129-a8af-7691-9071-543baa5fe8f5(submitted successfully on 2026-09-14 at 18:24 UTC with the same sanitized findings; no raw logs or conversation attached).stephenchurch-prog commentedon Sep 15, 2026
15 September 2026 — recurrence on 26.908.9136.0; recovery after path repairs and full Windows restart
Following up on my 29 August report. On Windows desktop package
OpenAI.Codex_26.908.9136.0, I again encountered a grey Send spinner: a new local chat could complete its first message, but its second message would not submit. Existing conversations were also affected. Mobile/remote messages continued to execute on the same Laptop. Earlier in the incident, the desktop window went white; reopening/updating restored the display but did not restore reliable submission.Observed evidence
Conversation state not found,Received turn/started for unknown conversation, andReceived turn/completed for unknown conversation.node_replfailed to start with path-not-found (OS error 3), andcodex_appreported an invalid directory (OS error 267).Repairs and verification
Current status: sending is working in this session. This is a recovery observation, not a confirmed permanent fix. We did not test a Windows restart before the path repairs, so we cannot separate the effect of rebooting from the repairs. No session database/history reset, clean-profile migration or reinstall was performed in this repair sequence.
Please investigate both stale installed-runtime references after updates and conversation/composer state reconciliation. They may be separate faults. This comment contains sanitized diagnostic findings only; no private workspace paths, account details, raw logs or conversation contents are attached.
PilotFlying commentedon Sep 19, 2026
Based on @ashjo42's analysis here and @rwhepburn's selective restore in #40968, I had Claude build a PowerShell script to automate the recovery (please review, use at your own risk).
See: #40968 (comment)
marcinszymczak96-source commentedon Sep 19, 2026
Reproduction on Windows Desktop 26.915.31945
I am reproducing the same Local Work composer lock on a newer Windows desktop build.
Environment
App version: 26.915.31945
Windows 11 Pro
Windows version: 10.0.26200
Build: 26200
Architecture: x64
Agent environment: Windows native
WSL: not installed
Affected Local Work session
Session ID: 01a0ba59-4852-70c3-ad4f-7817505bc4c8
Reproduction:
Create a new Local Work task.
Send the first prompt.
The task executes and completes normally.
After completion, the composer does not return to a sendable/idle state.
A follow-up message in the same thread cannot be submitted.
Creating another new Local Work task again allows one initial prompt, after which the same problem repeats.
Restarting the desktop application does not resolve the issue.
The affected rollout terminates normally:
2026-09-19T16:00:21.160Z response_item message final_answer
2026-09-19T16:00:21.171Z token_usage_record
2026-09-19T16:00:21.172Z event_msg token_count
2026-09-19T16:00:21.187Z event_msg task_complete
2026-09-19T16:00:27.208Z event_msg thread_settings_applied
thread_settings_applied is the final record in the transcript. There are no additional events after it.
The task therefore appears to complete normally, but the Windows Desktop Local Work UI/composer remains in a non-interactive state after the authoritative task_complete.
I have attached a sanitized structural transcript excerpt. I am not attaching the raw rollout because it contains private workspace/business information.
Regarding sandbox logs: .codex.sandbox exists on this machine, but there is no sandbox log corresponding to the September 19 reproduction. The most recent sandbox log is from September 17, so I have not attached it because it does not correspond to the affected session.
Line Timestamp Type PayloadType Status Phase
268 2026-09-19T15:58:01.964Z event_msg item_completed
269 2026-09-19T15:58:01.966Z response_item reasoning
270 2026-09-19T15:58:03.291Z event_msg item_completed
271 2026-09-19T15:58:03.293Z response_item reasoning
272 2026-09-19T16:00:21.158Z event_msg item_completed
273 2026-09-19T16:00:21.160Z response_item message final_answer
274 2026-09-19T16:00:21.171Z token_usage_record
275 2026-09-19T16:00:21.172Z event_msg token_count
276 2026-09-19T16:00:21.187Z event_msg task_complete
277 2026-09-19T16:00:27.208Z event_msg thread_settings_applied
KotMatrosk1n commentedon Sep 19, 2026
September 19: independent confirmation of stuck local configuration reads on Windows 26.915.31945
This installation reproduces the
codex-homefailure described in the September 15 investigation. Targeted cancellation/refetch restored sending in an existing local task. Native logs provide a further localization: the original requests reached the desktop handler after the app-server initialization handshake had succeeded.Environment
26.915.31945, build9922.OpenAI.Codex 26.915.4065.0. This differs from the application version.codex-cli 0.155.0-alpha.9.2.10.0.26200.9457, 25H2; Windows-native agent.Failure captured before recovery
The user reported being unable to continue existing tasks and repeatedly creating new tasks. A read-only renderer capture at 20:40:11 UTC showed:
Both local query forms remained
pending/fetching, without data or error:The collector traversed React fibers, including alternates. It can therefore record multiple/stale composer prop sets; these are structural diagnostic observations, not a direct measurement of the native button's disabled property. The query states, subsequent native request logs, and successful user submissions provide independent corroboration.
Observed recovery timeline — 2026-09-19, UTC
The app was restarted with a local diagnostic connection so a helper could retry only the stalled reads. The failure was still present after that restart, before intervention.
electron-fetch-handlerlogged the originalcodex-homerequests, with omitted and explicit local host respectively.loading-local-config.turn/startresponse,errorCode=null.turn/startresponse in the same app session.turn/startresponse; query recovery attempts remained two total.The user confirmed that sending worked, and subsequent messages in this existing task succeeded. Query recovery was visible within the next approximately 2.54-second sample interval; this is not an exact request-latency measurement.
Temporary workaround used
A local helper observed only the two query keys listed above. Once a query remained pending/fetching without data or error for at least 15 seconds, it called
cancelQueries({queryKey, exact: true}, {silent: true}), followed byrefetchQueries({queryKey, exact: true, type: 'all'}, {throwOnError: true})on the existing query client. In this occurrence, one retry per query was enough.The helper limited retries to two per query object and eight per window, with a maximum monitoring duration of 12 hours or until the diagnostic connection closed. It did not click Send or call/retry
turn/start. The app was reopened with a loopback diagnostic port using an independent, one-use Windows Task Scheduler launcher; a helper launched as a child of Codex had previously disappeared before relaunch. This launcher issue was separate from the composer blocker.This is a diagnostic session workaround, not a permanent installed patch or an officially supported recovery command. Ending monitoring does not undo already recovered query data, but a normal app restart may reintroduce the bug. Once configuration becomes available, the app may continue a submission the user already attempted, so repeating Send while it is pending is unnecessary.
Installed code and isolated test
The inspected renderer/main bundles were verified byte-for-byte against the installed package.
app-initial-6c4523b43a11.js,Hv → Lon → Rv.post/sendRequestsupplies the local query/bridge path. Thecodex-homequery configuration includes a five-second stale time; that is not a request timeout.vscode://codex/requests,Rv.sendRequestcreates a pending-map entry and waits for a matchingfetch-responseor an abort signal. No hard timeout is scheduled in that branch.main-LM8MUIFp.js,readCodexHomePathslogs entry into the native handler.handleVsCodeFetchRequestawaits the handler, then sends the response through the chunked-message sender. The available log does not record the original handler's completion or the renderer's receipt of its response.cancel-fetch; a late reply to that cancelled request was ignored. A fresh request with a valid reply resolved once, including when the reply was duplicated. This verifies the bridge's behavior under a simulated missing response, not why the original response went missing.Scope and limitations
The evidence localizes this occurrence to configuration preparation. It does not establish the same cause for every disabled-composer report.
The requests reached the native handler after a successful handshake, but we cannot yet distinguish a later internal await from response delivery/lifecycle loss. We did not capture HTTP-like response statuses for these retries and do not claim a captured status 200.
The successful intervention did not reset databases, rewrite transcripts, change permissions, disable plugins, or modify the installed app. Earlier unsuccessful profile-recovery attempts on this machine are a confounder; this is not a clean-profile A/B test. No fresh restart without the workaround has been tested since recovery, so this remains a session workaround.
Suggested maintainer instrumentation and regression coverage
turn/start.This comment contains sanitized structural evidence only. No account identifiers, private task IDs, machine/user names, local filesystem paths, prompt contents, credentials, or raw logs are included. A sanitized structural evidence extract and offline test harness are available if maintainers need them.
ashjo42 commentedon Sep 23, 2026
September 24: downloadable recovery scripts for the confirmed local-config blocker
This issue was reported on August 26 and is still open on September 24. It continues to block the basic ability to send messages on my Windows machine, including Codex 26.917.8451.0. Users should not have to diagnose the renderer and maintain their own recovery helper just to use Send.
I am sharing the working local workaround so other affected users have something concrete to try while this is unresolved:
This is an unofficial, user-maintained workaround, not an OpenAI-supported fix. It targets the particular
loading-local-configfailure described in my earlier evidence, not every cause of a disabled composer.What it does
The helper handles only these two exact read-only query keys, and only while the main composer is blocked by
loading-local-config:After approximately 15 seconds of an unfinished read with no data, it cancels the old request through the existing AbortSignal path before refetching. Automatic retries are limited to two; exhaustion preserves the draft and exposes a Retry button. It does not click Send, retry
turn/start, manufacture successful config data, reset databases/history, switch accounts, or modify the installed app. A submission already waiting inside Codex may continue when real configuration becomes available.The first helper used an exact-version allowlist, which made compatible small app updates disable the workaround. That design has now been replaced with automatic structural interface checks plus an isolated runtime cancellation test. Build numbers and minified identifier changes alone do not require another allowlist entry. Actual interface incompatibility produces an explicit failure instead of claiming the helper is attached.
How to use it
Download and extract the entire ZIP into one folder. Requirements: Windows
OpenAI.Codexpackage, PowerShell 7, and Node.js (tested with 25.2.1; required capabilities are checked). Save your draft and quit Codex yourself if it is already running normally, then run this from the extracted folder:Open the original task/composer. The launcher uses the existing installation/profile, enables a loopback-only debugging endpoint on 9228, checks the installed cancellation interface and current query library, then attaches. The README includes status, failure handling, stopping, and optional Node-path instructions. The debug port permits local control of the app; do not expose it. Fully quitting Codex and reopening normally removes that diagnostic session. Normal app launches do not automatically load the helper.
What was verified
On 26.917.8451.0, both real stuck reads recovered after one retry each, the config blocker disappeared, and I confirmed that I could send a message again. Recovery retained the same running app, account and conversation history. Repeating the recovery entry reused the existing helper. That version was not added to an allowlist.
The published package passes 43 automated tests and the installed-interface check; the portable launchers passed read-only preflight on this machine. This is still one affected machine, not a cross-machine guarantee. No private conversations, credentials, runtime logs, machine-specific paths or extracted application source are included in the download. The interface baseline contains structural fingerprints, not application source snippets.
Requested product action
Please assign/confirm an owner for this failure path and provide a triage status. The product needs a bounded timeout with complete request cleanup, an actionable configuration error/Retry, draft preservation, and protection against duplicate submission. Please cover lost/late replies, startup, window reload and task switching in regression tests.