You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
{{ message }}
Repository navigation
Stop replication streams properly when they are disposed early - #6716
Depends on #6715, which isn't merged yet; its commit shows up here until it is.
Leaving the loop. Breaking out of await foreach over a replication stream, or an exception in the consumer, left the inner enumerator undisposed. The connection stayed in replication mode with its feedback timers running, and every other command failed with NpgsqlOperationInProgressException. The enumerators are now disposed, which stops streaming:
Physical replication ends copy mode with CopyDone, which keeps the walsender ready for the next START_REPLICATION and keeps temporary slots.
Logical replication cancels the command, since a logical walsender can't stream again after CopyDone. Like any error, the cancellation drops the session's temporary slots, which the logical StartReplication methods now document. Servers before PostgreSQL 10 ignore cancellation requests on replication connections, so with them the logical stop breaks the connection instead.
A final status update reports the processed position first; for logical replication this is best effort, since the walsender may handle the cancellation before it reads the update.
Skipping what the consumer didn't read of the message it held waits for the rest of that message at most WalReceiverTimeout, or 30 s if that's infinite or too large for a socket, like the rest of stopping.
If stopping fails, the connection is broken, and the exception that made the consumer stop is never replaced.
Late status updates. Status updates that were still on their way when a stream ended (e.g. from a timer or another thread) could be written after the end of the command, interleaved with the next one, also with the START_REPLICATION of the next stream. The end of the stream now waits for an update in progress, and later ones are dropped until the next stream is in copy mode.
Unread data. Whatever the consumer didn't read of the message it held is skipped first, also when a plugin like pgoutput reads the data directly from the buffer. Reading beyond the end of a message breaks the connection.
Cancellation. After cancellation, messages that were already on their way were still handed out until the server's error arrived. They are now skipped before they count as received, so the next START_REPLICATION from the reported position gets them again. This makes PhysicalReplicationTests reliable, so they run again (some of them also used colliding slot names).
A second stream. Starting a second stream while one was in progress overwrote the state of the first one before failing, so disposing the connection didn't stop the first stream anymore. It now fails before touching anything, and a start that fails leaves no state behind.
Oversize messages. A message bigger than the read buffer (e.g. a long notice) made the connector switch to a bigger buffer while the stream kept reading from the old one. This is fixed for the replication stream itself; the pgoutput decoder still reads from the old buffer, which Read pgoutput messages from the connector's current read buffer #6721 fixes.
How a real server gets there
Every case was run on PostgreSQL 18.6, most also on 14.24, against main, against #6715 where it matters, and against this PR:
Leaving the loop, then using the connection: a consumer stops early because it has what it needs or because its own code throws (a failing sink), and then runs IDENTIFY_SYSTEM, a slot command or StartReplication again. On main IDENTIFY_SYSTEM threw NpgsqlOperationInProgressException ("The connection is already in state 'Replication'"), pg_stat_replication kept showing the walsender in catchup with a moving reply_time (the status timer kept running), the next StartReplication failed the same way, and the server logged "unexpected EOF on standby connection" at the disposal. With this PR IDENTIFY_SYSTEM worked, the walsender went back to its startup state, and a second START_REPLICATION on the same walsender worked; test_decoding and pgoutput behaved the same, with the server logging the cancellation and the release of the slot.
Stopping inside a big message: a physical stream that catches up gets XLogData of up to 128 kB, 16 times the 8-kB read buffer. This PR skipped the rest of a 125,944-byte message of which the consumer had read 100 bytes, sent CopyDone and drained, and the connection worked; the same for 100 bytes of a 20,000-character pgoutput value.
An unread pgoutput row: a consumer that filters by relation stops after a change without reading its row. Main's DisposeAsync read the row's bytes as backend messages ("There is not enough data left in the buffer" from ParameterDescriptionMessage.Load, swallowed). This PR skipped the row and sent the cancellation, and the slot was released.
A second StartReplication: on main, "break, then StartReplication again" does exactly this, because the break leaves the first enumerator suspended. In Release, DisposeAsync then returned at once with both timers still set, and no cancellation reached the server ("unexpected EOF on standby connection"); a Debug build stopped the process on a Debug.Assert. With this PR the first stream was untouched, and DisposeAsync stopped it within about 25 ms.
Cancellation with data in flight, as during a catch-up or on a busy logical stream: with about 6 MB of backlog, main handed out 3 more 131,072-byte messages after the cancellation, this PR none.
The server goes away while the consumer throws (pg_terminate_backend, a shutdown, a lost connection): this PR logs event 50013, surfaces the consumer's exception and breaks the connection. Main has no stop path, so this test guards the new code.
A status update still on its way when the stream ends (a timer callback, or SendStatusUpdate on another thread): forced by holding the feedback semaphore and suspending the walsender, so that the next command stays blocked in its write. On main and on Handle the end of a replication stream at timeline switches and shutdown #6715, the late update failed with "Did not write the amount of bytes the message length specified", the connection broke, and the server logged "incomplete message from client". With this PR the end of the stream waited, and the update went out first. Without forcing, the window is one status-update write per stream end, so this is rare; there is no test for it.
Reading beyond a message: the only real case found is the stream abort that protocol version 4 with streaming = on misread before Fix pgoutput decoding of two-phase messages, stream aborts and bad data #6710. On main (18.6 and 16.15) it handed out garbage and then left the connector Ready while the walsender was still in copy mode, so that the next command was fatal on the server; with this PR it fails with "A replication message was read beyond its end." and breaks the connection. With that PR merged, the check is defensive hardening: it turns a silent misread into a clean break. No test.
A long notice mid-stream: notices can come between CopyData messages at any time. A realistic trigger is a publication row filter (PostgreSQL 15+) with websearch_to_tsquery and a row whose text holds more than about 8 KB of whitespace, which raises a notice that repeats the whole input. On 18.6 and 15.19 main failed with "Unknown replication message code 'd'" after the first row; with this PR the replication stream handles the notice, and the failure moves to the pgoutput decoder. The mock test's physical variant needs a debug setting on a real server.
Tests
ReplicationStopMockTests (11 cases, mock): on Handle the end of a replication stream at timeline switches and shutdown #6715's code, 10 of them fail (the stop tests time out because nothing ends copy mode, messages are handed out after the cancellation, a status update goes out before copy mode, and the skip when stopping has no bound), and Oversize_message_during_streaming hangs.
Live: ReplicationStopTests<Logical|Physical>.Stop_early_and_go_on, PgOutputStopTests.Stop_in_the_middle_of_a_change (a 20,000-character row), and the 9 PhysicalReplicationTests, which were [Explicit("Flakiness")] and now run ([NonParallelizable]).
The replication tests pass against PostgreSQL 18.6, in Debug and Release.
For the reviewer
New public constants in NpgsqlEventId: 50008 (StoppingReplication) and 50013 (StoppingReplicationFailed), both at Debug level. The class suppresses RS0016, so PublicAPI.Unshipped.txt doesn't change; there is no other API change.
On PostgreSQL 14 to 17, the server may not send pgoutput's Relation messages again in the next stream on the same connection after such a cancellation (on 14 after any error, on 15 to 17 if the connection created the slot with an exported snapshot; fixed in PostgreSQL 18 by 80b727eb9de). The pgoutput StartReplication docs say to start the next stream on a new connection, and the test avoids it.
Not changed: the logical stop doesn't wait for the server to read its final status update before it cancels. A busy walsender only reads replies once its output buffer fills, so stops would stall in large transactions.
Behavior changes, also in the 11.0 release notes: leaving the loop stops the stream and leaves the connection usable; a logical stop drops the session's temporary slots, and its final status update is best effort; SendStatusUpdate after the loop throws InvalidOperationException (send it before leaving the loop, or pass the processed position as walLocation when starting again); a second StartReplication while one is active throws NpgsqlOperationInProgressException.
- At the end of a historic timeline (e.g. after the standby we stream
from got promoted), the server ends copy mode with CopyDone. Npgsql
expected only CopyData and broke the connection ("Received backend
message CopyDone while expecting CopyDataMessage"). It now answers
with CopyDone, reads the next timeline the server sends, both
CommandCompletes and ReadyForQuery, and ends the enumeration normally,
leaving the connection usable. Status updates stop before our
CopyDone, since the protocol doesn't allow CopyData after it. The next
timeline is logged, and the StartReplication docs explain how to
continue: IDENTIFY_SYSTEM returns the current timeline and
TIMELINE_HISTORY the position where it branched off, which can be
before the end of the WAL received on the old timeline.
- Asked to start at the end of a historic timeline, the server doesn't
enter copy mode but sends the next timeline right away, which Npgsql
treated as an unexpected message. The enumeration now ends right away.
- A walsender that exits after everything has been replicated (e.g. at
server shutdown, npgsql#5752) sends CommandComplete, which also broke the
connection with a misleading error. It now throws an NpgsqlException
saying that the server ended the replication stream.
- In logical replication, unknown CopyData message types are skipped
instead of breaking the connection, like the logical replication
worker, which ignores them on purpose. Physical replication keeps
rejecting them, like walreceiver, since it must not lose WAL.
Keepalive fields that newer servers may add are skipped in both.
- In physical replication, the received position reported to the server
was the server's own WAL end, not the end of the WAL received, so
pg_stat_replication.write_lsn and synchronous_commit = remote_write
treated WAL as written before it arrived. It is now the end of the
data the consumer is done with, like walreceiver reports what it
wrote.
- LastReceivedLsn starts over at the start position of each stream
instead of keeping the maximum of all previous streams, which was
wrong when continuing on a new timeline at a lower position.
- The XLogData stream is disposed after each message instead of later in
cleanup, where it could skip data based on a stale position: a server
error that ended the stream after a keepalive (e.g. after
pg_cancel_backend) turned into a timeout and a broken connection.
The new cluster tests stream physically across a standby's promotion
and through a fast shutdown, using the throwaway clusters from
NPGSQL_TEST_PG_BIN.
Co-Authored-By: Claude Opus 5.5 <[email protected]>
- Breaking out of a replication enumeration, or an exception in the
consumer, left the inner enumerator undisposed. The connection stayed
in replication mode with its feedback timers running, and every other
command failed with NpgsqlOperationInProgressException. The
enumerators are now disposed, which stops streaming: physical
replication ends copy mode with CopyDone, which keeps the walsender
ready for the next START_REPLICATION and keeps temporary slots;
logical replication cancels the command, since a logical walsender
can't stream again after CopyDone. Like any error, the cancellation
drops the temporary slots of the session (documented on the logical
StartReplication methods). Servers before PostgreSQL 10 ignore
cancellation requests on replication connections, so with them the
logical stop breaks the connection instead.
A final status update reports the processed position first; for
logical replication this is best effort, since the walsender may
handle the cancellation before it reads the update. If stopping fails,
the connection is broken; the exception that made the consumer stop is
never replaced. On PostgreSQL 14-17, the server may not send
pgoutput's Relation messages again in the next stream on the same
connection after such a cancellation (on 14 after any error, on 15-17
if the connection created the slot with an exported snapshot; fixed in
PostgreSQL 18 by 80b727eb9de). This is documented on the pgoutput
StartReplication, and the test avoids it.
- Status updates that were still on their way when a stream ended (e.g.
from a timer or another thread) could be written after the end of the
command, interleaved with the next one. They are now dropped.
- Whatever the consumer didn't read of the message it held is skipped
first, also when a plugin like pgoutput reads the data directly from
the buffer. Reading beyond the end of a message breaks the connection.
- After cancellation, messages that were already on their way were still
handed out until the server's error arrived. They are now skipped.
This makes the physical replication tests reliable, so they run again
(some of them also used colliding slot names).
- Starting a second stream while one was in progress overwrote the state
of the first one before failing, so disposing the connection didn't
stop the first stream anymore. It now fails before touching anything,
and a start that fails leaves no state behind.
- A message bigger than the read buffer (e.g. a long notice) made the
connector switch to a bigger buffer while the stream kept reading from
the old one. This is fixed for the replication stream itself; the
pgoutput decoder still reads from the old buffer.
Co-Authored-By: Claude Opus 5.5 <[email protected]>
The reason will be displayed to describe this comment to others. Learn more.
🟡 Changes recommended
Unresolved replication races can corrupt the protocol on immediate restart, acknowledge WAL before it arrives, and advance logical positions or send replies after cancellation.
This PR adds early-stop cleanup to Npgsql replication streams so leaving an enumeration can release replication mode and allow connection reuse, addressing #5523. It also includes the stream-end handling from dependency #6715.
Changes:
Dispose inner enumerators and stop physical or logical replication using the appropriate protocol.
Coordinate feedback shutdown, handle unread payloads and cancellation, and follow read-buffer replacements.
Add mock and live regression tests, restore physical replication tests, and document lifecycle behavior.
- A status update could go out while a stream started, before the
server's CopyBothResponse: one sent then, or one that had waited
while the previous stream ended and only got its turn after the next
stream reset the flag that stops them. In the write buffer, it could
interleave with START_REPLICATION. Status updates now stay stopped
until the server is in copy mode, and are allowed again under the
feedback semaphore.
- Stopping a stream skipped the rest of the message the consumer held
with the stream's read timeout, which is infinite with an infinite
WalReceiverTimeout, so a server that stopped sending in the middle of
a message made the stop hang. The skip now has the bound of the rest
of stopping.
Co-Authored-By: Claude Opus 5.5 <[email protected]>
The reason will be displayed to describe this comment to others. Learn more.
🟡 Changes recommended
Unresolved cancellation races and received-position accounting errors can yield messages after cancellation, skip messages on resume, or deadlock synchronous commits.
This sets an inactivity timeout rather than an overall deadline: the read buffer restarts its timeout after successful reads. A trickling message tail can therefore keep disposal pending far beyond WalReceiverTimeout or the 30-second fallback. Enforce an overall deadline for the skip, breaking the connector and awaiting the outstanding read when it expires, and cover this with a trickling-payload test.
Apply the timeout range check before installing the fallback
ToBufferTimeout treats positive values above int.MaxValue milliseconds as infinite, but this fallback does not. With WalReceiverTimeout = TimeSpan.FromDays(30), stopping therefore installs an infinite read timeout and can wait indefinitely for a missing message tail or stream-end response. Apply the same representable-range check here so effectively infinite settings receive the 30-second fallback.
The bound for stopping used WalReceiverTimeout unless it was zero or
infinite, so a value that is too large for the buffers' timeouts (more
than int.MaxValue milliseconds, e.g. 30 days), which they treat as no
timeout, made stopping wait forever again. Such values now get the
30-second fallback too.
Co-Authored-By: Claude Opus 5.5 <[email protected]>
The reason will be displayed to describe this comment to others. Learn more.
Copilot was unable to review this pull request because the user who requested the review has insufficient remaining quota. Try requesting a review at a lower effort level.
An organization owner can choose the repository organization as the billing source for reviews requested by members with a paid Copilot license. Learn about Copilot code review billing.
The timeout range is fixed in 3d29849: a WalReceiverTimeout too large for the buffers' timeouts (e.g. 30 days), which they treat as no timeout, now gets the 30-second fallback too, and Stopping_waits_for_the_rest_of_a_held_message_with_a_bound checks that case.
The overall deadline I'd leave: the bound applies to each read, like Npgsql's other timeouts, so it stops a peer that stalled, not one that's slow. A slow link that keeps delivering the rest of a message (at most 128 kB) is making progress, and an overall deadline would turn a slow stop into a broken connection.
This branch has not been deployed
No deployments
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
Depends on #6715, which isn't merged yet; its commit shows up here until it is.
await foreachover a replication stream, or an exception in the consumer, left the inner enumerator undisposed. The connection stayed in replication mode with its feedback timers running, and every other command failed with NpgsqlOperationInProgressException. The enumerators are now disposed, which stops streaming:StartReplicationmethods now document. Servers before PostgreSQL 10 ignore cancellation requests on replication connections, so with them the logical stop breaks the connection instead.PhysicalReplicationTestsreliable, so they run again (some of them also used colliding slot names).How a real server gets there
Every case was run on PostgreSQL 18.6, most also on 14.24, against main, against #6715 where it matters, and against this PR:
pg_stat_replicationkept showing the walsender in catchup with a movingreply_time(the status timer kept running), the next StartReplication failed the same way, and the server logged "unexpected EOF on standby connection" at the disposal. With this PR IDENTIFY_SYSTEM worked, the walsender went back to its startup state, and a second START_REPLICATION on the same walsender worked; test_decoding and pgoutput behaved the same, with the server logging the cancellation and the release of the slot.Debug.Assert. With this PR the first stream was untouched, and DisposeAsync stopped it within about 25 ms.pg_terminate_backend, a shutdown, a lost connection): this PR logs event 50013, surfaces the consumer's exception and breaks the connection. Main has no stop path, so this test guards the new code.SendStatusUpdateon another thread): forced by holding the feedback semaphore and suspending the walsender, so that the next command stays blocked in its write. On main and on Handle the end of a replication stream at timeline switches and shutdown #6715, the late update failed with "Did not write the amount of bytes the message length specified", the connection broke, and the server logged "incomplete message from client". With this PR the end of the stream waited, and the update went out first. Without forcing, the window is one status-update write per stream end, so this is rare; there is no test for it.websearch_to_tsqueryand a row whose text holds more than about 8 KB of whitespace, which raises a notice that repeats the whole input. On 18.6 and 15.19 main failed with "Unknown replication message code 'd'" after the first row; with this PR the replication stream handles the notice, and the failure moves to the pgoutput decoder. The mock test's physical variant needs a debug setting on a real server.Tests
ReplicationStopMockTests(11 cases, mock): on Handle the end of a replication stream at timeline switches and shutdown #6715's code, 10 of them fail (the stop tests time out because nothing ends copy mode, messages are handed out after the cancellation, a status update goes out before copy mode, and the skip when stopping has no bound), andOversize_message_during_streaminghangs.ReplicationStopTests<Logical|Physical>.Stop_early_and_go_on,PgOutputStopTests.Stop_in_the_middle_of_a_change(a 20,000-character row), and the 9PhysicalReplicationTests, which were[Explicit("Flakiness")]and now run ([NonParallelizable]).For the reviewer
NpgsqlEventId: 50008 (StoppingReplication) and 50013 (StoppingReplicationFailed), both at Debug level. The class suppresses RS0016, soPublicAPI.Unshipped.txtdoesn't change; there is no other API change.StartReplicationdocs say to start the next stream on a new connection, and the test avoids it.SendStatusUpdateafter the loop throws InvalidOperationException (send it before leaving the loop, or pass the processed position aswalLocationwhen starting again); a second StartReplication while one is active throws NpgsqlOperationInProgressException.Dependencies and merge order
ReplicationConnection.DisposeAsynccan run into it (abreakwhile DisposeAsync stopped the stream threw NotSupportedException, and a DisposeAsync during the consumer's stop was still pending after 20 s), which that PR fixes. That PR in turn goes in with Don't return the read buffer of a broken connector to the ArrayPool #6717 or after it. So the stream PRs go in back to back: Handle the end of a replication stream at timeline switches and shutdown #6715, this one, Don't return the read buffer of a broken connector to the ArrayPool #6717, Let a running MoveNextAsync end when the replication connection is disposed #6718.Fixes #5523
Part of #6699 (the oversize-message bullet; #6721 completes it)