masoud-najafi
left a comment
There was a problem hiding this comment.
Just a short comment about this phrase: "It is implementation-defined whether and which connections between two connectors of kind input with intervalVariability that is not triggered are allowed." This leaves the door open for different interpretations about connecting these "time-based" clocks. For example as you indicated for establishing a constraint equality or have a union of several clock ticks. This would make an SSP model with such connections completely tool dependent.
Indeed it does, however as there is currently no established practice on how to handle this across tools, I think this is currently the only thing we can do. If common or multiple common practice is established, we can either tighten the requirements in future releases, and/or add additional attributes to select between multiple ways. |
Co-authored-by: Klaus Schuch <[email protected]>
|
Web meeting 2024-05-08 |