Decode the NY9100DW burner entities when no Fuel_ token is reported - #779

Open
Varshavia wants to merge 1 commit into
mbillow:mainfrom
Varshavia:fix/ny-fuel-gas
Open

Varshavia wants to merge 1 commit into
mbillow:mainfrom
Varshavia:fix/ny-fuel-gas

Conversation

@Varshavia

Copy link
Copy Markdown

What is wrong

The per-burner entities from #450 are gated on a Fuel_Gas token in /mode/vs/0 options. The NY9100DW/AA (TP1X_DA-KS-RANGE-0102X) reports no Fuel_* token at all, so it only gets the raw cooktop_monitoring diagnostic.

The issue's data shows its mask matches the bit map already verified on the gas NX60T8311SS: with each burner lit alone, cooktopMonitoring read 1, 2, 4, 8 and 16 for front-left, back-left, center, back-right and front-right.

Fixes #767

The change

_fuel_is_gas() in registry/capabilities/range.py:

  • If a Fuel_* token is present, behavior is unchanged: gas only when it is Fuel_Gas.
  • If no Fuel_* token is present, the board counts as gas only when its DeviceType_ value starts with NY.

Evidence

New test file: tests/test_range_ny9100dw_capabilities.py, a minimal synthetic resource set built from the values posted in the issue.

Result
New tests, before the fix 6 failed, 2 passed
New tests, after the fix 8 passed
New tests plus test_range_nx60t8311ss_capabilities.py, after the fix 27 passed

The 6 failures before the fix were the five single-burner cases and the all-off case: cooktop_monitoring stayed raw and active_burners did not exist. The 2 that passed before the fix are guards that must not change (NY with Fuel_Electric, and NE8300D).

ruff format --check, ruff check and ty check pass on custom_components and tests (ruff 0.16.1, ty 0.0.65).

What the local test run does and does not cover

These results are from Windows on Python 3.13, not CI's Python 3.14. Home Assistant's pytest plugin cannot start on Windows (it imports fcntl), so the suite ran with -p no:homeassistant and PYTHONUTF8=1. lru-dict was 1.4.1 instead of Home Assistant's pinned 1.3.0, because 1.3.0 has no Windows wheel for Python 3.13.

Tree Passed Failed Errors
This branch 2699 0 1192
Clean upstream/main 2691 0 1192

The 8 extra passes are the new tests, and the set of erroring tests is identical on both trees. All 1192 errors are missing Home Assistant fixtures (hass, enable_custom_integrations, recorder_mock), so those tests did not run locally. They include the config flow and coordinator tests. CI needs to confirm them.

Boards intentionally not touched

  • NX without a Fuel_* token: stays raw. There is no evidence for this case, and test_board_without_fuel_token_gets_raw_value_only keeps passing.
  • NE (electric) boards: stay raw. On an NE6516A-class board the field is a 0/1 flag rather than a bitmask (Gas range: cooktopMonitoring is a bitmask of lit burners (NX60T8311SS) #450).
  • BurnerOnAlter_On is not used as a signal: the electric NE8300D fixture carries it too. A test covers this.
  • NY boards that report Fuel_Electric: stay raw. The model prefix only fills in for a missing token and never overrides a reported one. A test covers this.

What only the reporter can verify on the real device

  • The active_burners sensor and the five cooktop_burner_N binary sensors appear after updating, and each follows the matching physical burner.
  • Combinations behave correctly. The issue tested each burner alone, so multi-burner values on this board are untested.
  • What happens to the existing raw cooktop_monitoring entity. Decoded boards no longer get it, so it may be left behind in the entity registry.

Assumptions

  • That other NY models also have this bit map. It is confirmed on one unit only.
  • That the NY prefix indicates a gas cooktop. This comes from the model-number note in the issue and has not been checked against any other NY board.
  • That DeviceType_ follows the retail model prefix. It does not always match the retail model: the NX60T8311SS reports NX9302T-.
  • That NY boards have five burners. The mask cannot report the burner count, so a four-burner NY board would show an unused Burner 5, the same limitation as the existing NX rule.

@Varshavia

Copy link
Copy Markdown
Author

@SlyWombat, thanks for the detailed report. This PR implements the NY rule from your issue. If you can test the branch (https://github.com/Varshavia/localthings/tree/fix/ny-fuel-gas), there are two things I can't check without the hardware: several burners lit at the same time, and whether the old raw cooktop_monitoring entity is left behind in the entity registry.

@SlyWombat

Copy link
Copy Markdown

Tested on the real NY9100DW. I applied only this PR's range.py change on top of v0.36.0, then restarted HA (2026.9.3).

Entities after the restart

  • New: sensor.<device>_active_burners and binary_sensor.<device>_burner_1 … _burner_5, all off/0 at idle.
  • The old raw cooktop_monitoring diagnostic is left behind in the entity registry. HA shows it as unavailable with restored: true, meaning it's no longer provided, so the user has to delete it by hand. It might be worth removing it on setup the way _drop_duplicate_cooktop_timer does for the cooktop timer.

Two burners lit together (front-left + back-left, twice, from the HA recorder):

Time Action active_burners burner_1 burner_2 burners 3–5
14:42:17 both on 1 → 2 (same second) on on off
14:42:30 both off 0 off off off
14:42:33 both on 2 on on off
14:42:44 both off 0 off off off

cooktop_running_state went Run/Ready in step. Observe pushed every change within a second.

Before this I'd checked each burner alone (1/2/4/8/16, as in #767), so bits 0–4 are each confirmed. Two at once now sums correctly too. I haven't tested more than two at once.

I've rolled back to v0.36.0 for now and will pick this up from a release. Thanks for the quick turnaround!

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Labels

None yet

Projects

None yet

Development

Successfully merging this pull request may close these issues.

NY9100DW (TP1X_DA-KS-RANGE-0102X, gas cooktop): no Fuel_Gas token, so per-burner sensors stay off; mask verified