Your Environment
- Version: 1.5
- Affected Component: AGW
- Affected Subcomponent: MME
- Deployment Environment: AWS (orc8r) bare-metal (AGW)
Describe the Issue
During scale testing, we observed on multiple gateways that after 5+ hrs we see attach procedure timeout on the UEs. In the mme logs we see
INFO S1AP tasks/s1ap/s1ap_mme_nas_procedur:0102 Received S1AP INITIAL_UE_MESSAGE ENB_UE_S1AP_ID 0xCB9B53 assoc-id:2
INFO S1AP tasks/s1ap/s1ap_mme_nas_procedur:0115 New Initial UE message received with eNB UE S1AP ID: 0xCB9B53 assoc-id :2
ERROR S1AP tasks/s1ap/s1ap_mme_nas_procedur:0252 Initial UE Message- Duplicate ENB_UE_S1AP_ID. Ignoring the message, eNB UE S1AP
To Reproduce
- Run attach/detach tests over a longer duration of time; approx 4+ hrs.
mme logs and syslog attached.
Problem starts to happen after 18:00 in the log.

vagw4_mme_trunc.log.zip
vagw4_syslog_trunc.zip
Your Environment
Describe the Issue
During scale testing, we observed on multiple gateways that after 5+ hrs we see attach procedure timeout on the UEs. In the mme logs we see
To Reproduce
mme logs and syslog attached.
Problem starts to happen after 18:00 in the log.

vagw4_mme_trunc.log.zip
vagw4_syslog_trunc.zip