Skip to content

Home holds 66 to 130 MiB per stalled link reader: upstream read-ahead and request copies #8601

Closed

Description

@lidge-jun

When a Child's reader stalls on a streamed response relayed by the Home, the Home process keeps growing well past the bytes in flight. This affects the HTTP link relay today, and it will also affect the link WebSocket once it exists. Measured on a 4-core Linux VM with four stalled sockets: peak RSS over idle per socket, kernel VmHWM reset at idle, fake upstream sending near-4 MiB events.

Run Request Upstream Transport Per socket
R1 1 KiB free-running, chunks up to 256 KiB WebSocket 100.6 MiB
R2 1 KiB held after 16 MiB per stream, chunks up to 256 KiB WebSocket 76.0 MiB
R3 1 KiB held after 16 MiB, chunks up to 256 KiB HTTP relay 66.3 MiB
R4 near-8 MiB held after 16 MiB, chunks up to 16 MiB WebSocket 134.9 MiB
R5 near-8 MiB held after 16 MiB, chunks up to 16 MiB HTTP relay 129.7 MiB

The trigger is a stalled reader. Two mechanisms show:

  • Read-ahead amplification. Bun's fetch keeps reading the upstream body ahead of a reader that does not consume it. R1 against R2: about 25 MiB per socket more when the upstream is not held. The upstream enqueued 14 to 39 MiB per stream by the stall when free-running.
  • Request copies. A near-8 MiB request costs about 60 MiB per socket more than a 1 KiB one on the HTTP relay (R5 against R3), so the request body is copied several times on its way upstream.

The Home has no process-wide bound on either, and an HTTP request holds this for as long as its reader stalls. Link WebSocket sockets live longer than HTTP requests, so 24 stalled sockets would hold about 3 GB on the Home. That is why this matters before enabling the link WebSocket. Possible directions: bound read-ahead by pulling the upstream body only as the reader drains; drop request-body copies once the upstream request is built. Not fixed in the link WebSocket PR.

Activity

  1. added
    bug
    on Nov 12, 2026
  2. lidge-jun commented on Nov 16, 2026

    @lidge-jun
    OwnerAuthor

    Owner decision (lidge-jun, 2026-11-16): apply paced upstream reads to every relayed Remote Link turn, not only while the link WebSocket feature is on; keep the WebSocket-only log fields behind that switch.

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment