Repository navigation
Description
Client or integration
Claude Code — Claude Desktop's Code tab, using OpenCodex's third-party gateway profile (not the standalone Claude Code terminal).
Area
Catalog / models
Summary
The Code tab has no reasoning-effort selector with the default static gateway profile on OpenCodex 2.83.0 and Claude Desktop 2.31226.1.0 on Windows.
OpenCodex converts persisted date aliases into non-date wire aliases such as claude-opus-4-8-p06q. In the installed Desktop build, the effort fallback normalizes terminal dates but preserves -p06q, then performs a canonical-model lookup. Consequently this alias does not inherit the claude-opus-4-8 effort options.
Related: #6810 reported the same symptom and suspected the alias mismatch. It was automatically closed for missing template fields, rather than resolved with a code fix. This report follows the bug template and adds locally verified normalization evidence on Windows.
Expected: the supported gateway configuration offers the model's actual effort levels. Unsupported levels should not be advertised just because an alias resembles Opus.
Reproduction
- Install
@bitkyc08/[email protected]and enable a routed model with a reasoning ladder. - Apply the default static gateway profile using
ocx claude desktop apply --gateway(or the dashboard's equivalent). - Confirm the generated Claude-3p profile has
modelDiscoveryEnabled: falseand a non-date alias such asclaude-opus-4-8-p06qininferenceModels. - Fully quit and open Claude Desktop; select a routed model in the Code tab.
- The effort selector is missing.
Observed configuration has 11 enabled models. The symptom was reported in the Code tab; a fresh end-to-end UI comparison after the local workaround has not yet been confirmed.
Version
OpenCodex @bitkyc08/opencodex 2.83.0, global npm installation.
Claude Desktop Windows package 2.31226.1.0.
The upstream main version of src/claude/desktop-profile.ts inspected when filing still calls desktopProfileWireAlias(assignment.alias) for non-Anthropic rows. The upstream build itself was not run.
Operating system
Windows 11 Pro, version 10.0.26300, build 26300, x64.
Provider and model
Not specific to one provider. Example affected route: volcengine-agent-plan/ark-code-latest; other enabled rows include native GPT and routed DeepSeek, GLM, Nemotron, LongCat, Step and Grok models.
Logs or error output
No gateway inference error is needed to trigger the issue; the client-side capability lookup fails before inference.
Code-level observations from the installed packages:
- OpenCodex
src/claude/desktop-profile.ts:desktopProfileWireAlias()transforms a stored date slot into ap-prefixed base36 suffix.renderDesktopProfile()sends that alias to Desktop. - Desktop bundle
.vite/build/index.chunk-EzXl5k4A.js: canonicalization (cS/IC) removes terminal eight-digit dates and context markers, but not the profile wire suffix. The effort fallback (X0t) looks up the normalized ID in a canonical table (L0t), containingclaude-opus-4-8. - The Code-surface resolver (
p3t) falls back to that lookup when no hybrid/model-catalog thinking metadata is available.
Result using the actual canonicalizer extracted locally from this installed Desktop build:
claude-opus-4-8-p06q[1m] -> claude-opus-4-8-p06q (no canonical effort entry)
claude-opus-4-8-20260831[1m] -> claude-opus-4-8 (canonical effort entry exists)
Screenshots and supporting files
Local workaround applied, with backups:
- Render the existing persisted date alias (
assignment.alias) into the static profile instead of converting it to the non-date wire ID. - Register the previous
desktopProfileWireAlias(assignment.alias)as a compatibility alias, so existing sessions retain the same route after a service restart. - Update the applied static profile's 11 model names to those date aliases. Keep labels, family assignments, defaults and context flags unchanged.
Local verification passed:
- 11 date aliases resolve to their original routes.
- All 11 previous wire aliases remain resolvable in the patched registry.
- The actual installed Desktop canonicalizer recognizes all 11 date aliases, including
[1m]variants. - Incoming
thinking: {type: "adaptive"}plusoutput_config.effortpreserveslow,medium,high,xhigh, andmaxthroughanthropicToResponsesBody().
These checks verify registry/canonicalization/translation behavior. They do not establish that every upstream model accepts all five levels, and no paid inference requests were made. The post-workaround UI still requires confirmation after restarting Desktop.
Redacted configuration
Minimal illustrative static entry, omitting all credentials:
{
"inferenceProvider": "gateway",
"modelDiscoveryEnabled": false,
"inferenceModels": [
{
"name": "claude-opus-4-8-p06q",
"labelOverride": "Ark Code Latest (volcengine-agent-plan)",
"anthropicFamilyTier": "opus",
"isFamilyDefault": true,
"supports1m": true,
"prefer1m": true
}
]
}Persisted alias for this example: claudeCode.desktopProfile.assignments["volcengine-agent-plan/ark-code-latest"].alias = "claude-opus-4-8-20260831".
Suggested fix and acceptance criteria
Short term: restore aliases that the supported Desktop build can resolve for static profiles, retain previous aliases as decode-only compatibility mappings, and verify the UI on that Desktop build. Date aliases are a tested normalization workaround, not a complete capability solution: genuine Anthropic ID collisions and shared canonical model settings must be considered.
Long term: deliver per-route, authoritative effort capabilities through a metadata/discovery path that Desktop's Code tab demonstrably consumes. Avoid using the Opus fallback as the source of truth for arbitrary providers. Do not assume that switching to hybrid or discovery-only fixes this version; verify the actual client path, including precedence between the pinned list and discovery.
Regression coverage should check:
- Effort control appears for a routed model with a supported ladder in the default gateway configuration.
- Models without effort support have no effort control; narrower ladders do not gain unsupported levels.
- Old wire IDs, date aliases,
[1m]variants and genuine Anthropic models keep their intended routes. - Labels, family defaults and context options survive reapply/restart without losing effort metadata.
- A real Desktop smoke test confirms that changing effort produces the intended
output_config.effortand downstream mapped level.
Checks
- I searched existing issues and documentation, including Claude Desktop gateway (static catalog) drops the reasoning-effort picker; effort ladder only ships via discovery #6810 and the relevant installed source.
- I removed secrets, tokens, account details, request credentials, and personal data.
Activity
Ingwannu commentedon Oct 12, 2026
The current compatibility proposal is #7007; it remains Draft and is not a landed fix. I reviewed exact head 373abb1 and requested a cold-native defaultModel identity correction in review 5497050179.
Your acceptance criteria correctly distinguish an appearing effort menu from authoritative per-route capabilities. The Fable fallback proposal explicitly may expose levels outside a provider's ladder and may change client defaults, so its UI/menu, emitted effort and distinct model-switch behavior still need owner/reporter acceptance on the supported Desktop build. The previous date-alias workaround is not that receipt. No live patch, restart or provider request was made in this pass; leaving this issue open.
lidge-jun commentedon Oct 13, 2026
Fixed by #7007, squash-merged into dev as 9c36822 (not yet released). Desktop profiles now use distinct claude-fable-5-pXXX wire IDs, which Desktop 2.31226 effort fallback recognizes; previous Opus/date aliases remain decode-only.