[Bug]: Full test suite can time out installer fixture build under parallel load #352
test/install.test.ts builds the package once through synchronous node scripts/build.ts in packRelease(), with a 120,000 ms timeout.
While the full Node test runner is executing its many other files, that child build exceeded the timeout (127,997 ms observed). spawnSync() therefore returned status: null.
All five installer tests fail at the common assertion on line 33 before their individual installer behavior runs.
Expected: a machine that can complete the build should not fail all installer tests merely because the full suite is busy.
Actual: the shared fixture has a fixed 120-second synchronous build timeout and reports null !== 0.
Relevant output
✖ installer verifies the published checksum before installing (127997ms)
AssertionError: null !== 0
at test/install.test.ts:33
ℹ tests 677
ℹ pass 671
ℹ fail 5
The other four failures are the same shared packRelease() failure. The normal strict TypeScript check passed.
Possible fixes: raise or make the timeout load-aware; serialize/isolated-package this fixture so it does not compete with the full suite; or prepare a candidate archive once in a dedicated package-test step while retaining a test that verifies a fresh archive. Preserve the intent that the test does not depend on pre-existing dist/.
This is a test-harness/CI reliability finding; I did not verify it on GitHub Actions or a quiet machine.
Progress: PR #379 opened: the installer fixture build runs through an async execFile with a 600 s hang safety net and a clear timeout/exit message; could not reproduce the original 128 s build under 4x CPU oversubscription.
Merged in #379: the installer fixture's build and pack now run through an async execFile with a 600 s hang safety net, and a timeout or non-zero exit reports 'installer fixture build timed out after N ms' or 'exited with CODE after N ms' plus the child's output, instead of 'null !== 0'. The original 128 s build could not be reproduced (a quiet build takes ~1.2 s; 4x CPU oversubscription made it ~9 s), so the root cause of that one observation is unconfirmed. Keeping this open to see whether it recurs; other fixed spawnSync timeouts in test/ and scripts/ can fail with the same status-null shape and were left alone.
Activity
jimhoyd commentedon Sep 21, 2026
Progress: an agent has started on this; a PR will be linked here when it opens.
jimhoyd commentedon Sep 21, 2026
Progress: PR #379 opened: the installer fixture build runs through an async execFile with a 600 s hang safety net and a clear timeout/exit message; could not reproduce the original 128 s build under 4x CPU oversubscription.
Make the installer fixture build async with an explicit timeout error…
jimhoyd commentedon Sep 21, 2026
Merged in #379: the installer fixture's build and pack now run through an async execFile with a 600 s hang safety net, and a timeout or non-zero exit reports 'installer fixture build timed out after N ms' or 'exited with CODE after N ms' plus the child's output, instead of 'null !== 0'. The original 128 s build could not be reproduced (a quiet build takes ~1.2 s; 4x CPU oversubscription made it ~9 s), so the root cause of that one observation is unconfirmed. Keeping this open to see whether it recurs; other fixed spawnSync timeouts in test/ and scripts/ can fail with the same status-null shape and were left alone.
Bound remaining fixed subprocess timeouts with shared budgets (#413, #…