land_stage: drop rows timed in a known-bad window (qC14 ran with turbo on) #557
On mini, intel_pstate/no_turbo went back to 0 during the 2026-11 pass, with no reboot and no trace in the journal. The stage gate only checks turbo when a stage starts: qC14 passed it at 2026-10-31 16:33Z, and qC15 found turbo on at 2026-11-01 04:58Z. qC14's deep10m dense rows ran much faster than their rep-1 twins (rep 2 / rep 1 index build 0.40 to 0.75 for five of six backends, query p50 0.64 to 0.88). The stages before it, timed with turbo off, match rep 1 within about 5 percent. So qC14 was very likely timed with turbo on, and its rows are not comparable with the rest of the pass.
The results file on the bench host is append-only, and land_stage.py has no way to drop rows by time window. A qC14 re-run (queued after the current stages) will add new rows next to the old ones.
Proposal: a committed benchmarks/experiments/excluded_windows.json (from, to, reason, reference), applied in step 2 of land_stage.py to every row whose ts_utc falls in a window, with the count printed. The first window is [2026-10-31T16:33Z, 2026-11-01T05:25Z). The multipass overlay files have fixed names per arm and batch, so the re-run overwrites them; that is checked after the re-run.