Repository navigation
Description
Summary
When a stdio MCP server takes longer than ~10 s to start, Copilot CLI gives up waiting for its server/discover probe and sends a legacy initialize on the same stdio connection. A server built on the MCP Python SDK 2.3.0 then processes the queued server/discover first, locks the connection to the 2026-07-28 protocol, and rejects the initialize with -32022. Copilot CLI reports the server as failed and does not retry, even though both sides support 2026-07-28.
In the same situation, Claude Code (2.1.308) and the MCP Python SDK client re-probe with server/discover and connect successfully.
Environment
- Copilot CLI 1.0.103 (linux-x64)
- MCP server: any stdio server on
mcp(Python SDK) 2.3.0 with a slow cold start. Observed withanalytics-mcp0.8.0 (Google Analytics MCP server) andserena-agent2.1.0.
Steps to reproduce
-
Save this as
slow_server.py:# /// script # dependencies = ["mcp==2.3.0"] # /// import time time.sleep(12) # simulate a slow cold start from mcp.server.mcpserver import MCPServer server = MCPServer("slow-start-repro") @server.tool() def ping() -> str: return "pong" server.run("stdio")
-
Run
uv run --script slow_server.py < /dev/nullonce so the dependencies are cached. -
Start Copilot CLI with the server:
copilot -p "List the tools of the slowrepro MCP server. Do not call them." \ --additional-mcp-config '{"mcpServers":{"slowrepro":{"type":"local","command":"uv","args":["run","-q","--script","/path/to/slow_server.py"],"tools":["*"]}}}'
Actual behavior
The server is not connected. The log shows:
[WARNING] [rust:rt_mcp_connection] MCP server connection failed {"server_name":"...","raw_error":"failed to initialize MCP client: JSON-RPC error: -32022: connection is serving the 2026-07-28 protocol; the initialize handshake is not accepted({\"supported\":[\"2026-07-28\"],\"requested\":\"2025-11-25\"})"}
Frames captured between Copilot CLI and the server (seconds since spawn):
0.007 C->S {"id":0,"method":"server/discover","params":{"_meta":{"io.modelcontextprotocol/protocolVersion":"2026-07-28",...}}}
9.797 C->S {"id":1,"method":"initialize","params":{"protocolVersion":"2025-11-25",...}}
13.813 S->C {"id":0,"result":{"supportedVersions":["2026-07-28"],...}}
13.814 S->C {"id":1,"error":{"code":-32022,"message":"connection is serving the 2026-07-28 protocol; the initialize handshake is not accepted","data":{"supported":["2026-07-28"],"requested":"2025-11-25"}}}
Servers that normally start within 5 s also hit this right after the machine boots (cold disk cache, many processes starting at once). In that case, /mcp reload or restarting Copilot CLI connects them.
Expected behavior
The connection succeeds over 2026-07-28, as it does when the server starts within the timeout. Any of these would work:
- When the fallback
initializegets-32022anddata.supportedcontains a version the client supports, re-probe withserver/discoverat that version. The MCP Python SDK client does this (mcp/client/_probe.py: "The fallback handshake itself can be answered with -32022 … That code is itself positive modern evidence … so it triggers one re-probe at a mutual version instead of failing the connect."), and so does Claude Code. - Accept a late
server/discoverresponse that arrives after the fallback was sent. - For stdio, restart the server process before falling back, so the fallback does not share a connection with the unanswered probe.
Workaround
Make the server start faster than the probe timeout. In our case the venv is read-only at runtime, so .pyc files were never written. Installing the server with uv tool install --compile-bytecode brought startup down to ~3.5 s, and Copilot CLI then connected over 2026-07-28. This still fails occasionally right after the machine boots, as described above.
Activity
hstaudacher commentedon Nov 18, 2026
Thanks for the precise wire capture. Confirmed: when
server/discovertimes out, the legacyinitializefallback is sent on the same connection, so slow-starting stdio servers can fail to connect. This is separate from the cache-hint fix for #4888, and we've moved it to the backlog.robert-lukowski commentedon Nov 25, 2026
Additional data point from Windows 11 with Copilot CLI 1.0.115 and the official AWS MCP Proxy.
I am seeing intermittent MCP initialization failures with:
Environment:
What I tested:
An independent Python MCP SDK client successfully connected to the same proxy executable, using the same endpoint, metadata and AWS profiles. Initialization negotiated 2025-11-25 and completed in approximately 13.7 seconds; tools/list completed at approximately 20.6 seconds from process start and returned eight tools. No AWS tools were invoked.
A diagnostic stdio wrapper observed Copilot sending server/discover with 2026-07-28, followed by initialize with 2025-11-25 on the same connection. However, the wrapper experienced a roughly 10-second subprocess startup delay before reading stdin, so its timestamps cannot establish the actual interval between those messages. The capture was also incomplete at shutdown. I cannot conclusively attribute the -32022 response to a particular component from that capture.
Direct execution of the installed proxy still failed before increasing the Copilot MCP configuration timeout.
Direct execution with "timeout": 120000 connected successfully.
Switching back to uvx with mcp-proxy-for-aws-cli@latest, while retaining the same timeout, reproduced the failure. Switching back to direct execution restored connectivity.
The configuration that restored connectivity was:
{ "mcpServers": { "aws-mcp": { "type": "local", "timeout": 120000, "command": "C:\\Users\\<USER>\\.local\\bin\\mcp-proxy-for-aws-cli.exe", "args": [ "https://aws-mcp.eu-central-1.api.aws/mcp", "--metadata", "AWS_REGION=eu-central-1" ], "env": { "AWS_MCP_PROXY_PROFILES": "aws-dev aws-test" }, "tools": ["*"] } } }The executable was installed with:
This is an observed workaround on one workstation, not a confirmed root-cause fix. The uvx and installed environments were not fully compared, and validation after reboot and on another workstation is still pending.
Does the per-server timeout setting also control the server/discover probe timeout in 1.0.115, or is that probe governed by a separate limit? Is there a supported way to avoid a legacy initialize fallback on an already-probed stdio connection?