Where it lives: upstream vLLM, reachable only in a venv that pairs transformers >=5.16 with vLLM <=0.25 — i.e. feature/granite-turboctc-default (ef43e69), not main, which pins transformers<5.10.

transformers 5.16 renamed layer type attention -> full_attention and rewrites the value inside PreTrainedConfig.__init__, so even an old config file loads back with the new name. vLLM's table has only the old key:

# vllm/model_executor/models/granitemoehybrid.py:319  (0.19.1 .. 0.25.0)
ALL_DECODER_LAYER_TYPES = {
    "attention": GraniteMoeHybridAttentionDecoderLayer,
    "mamba": GraniteMoeHybridMambaDecoderLayer,
}
...
layer_class = ALL_DECODER_LAYER_TYPES[config.layer_types[layer_idx]]
(EngineCore pid=9824) KeyError: 'full_attention'

Confirmed on both 0.19.1 and 0.20.2. Fixed upstream in vLLM 0.26.0 (0.25.0 still broken), which added "full_attention" alongside.

Two distinct consequences

1. The equivalence tier cannot run — 14 failures + 19 nested. Those tests build their upstream reference with transformers, save_pretrained() it, and hand the directory to vLLM; the saved config now says full_attention and its architectures field routes to vLLM's stale class. So the control group will not start. Our own GraniteSwitchForCausalLM is unaffected: it builds layers through a closure and never consults that table.

Affected: test_skinning_equivalence_vllm[_thorough], test_generation_equivalence, test_granite4_fullsize, test_granite4_mini (9), test_upstream_equivalence.

2. A narrow serving regression. In a venv built from this branch (transformers>=5.16 via the audio extra, vllm<=0.25):

vllm serve ./granite-switch-4.2-3b-audio   # fine - our class, no table
vllm serve ibm-granite/granite-4.0-micro   # KeyError: 'full_attention'

Composed Granite Switch checkpoints are never affected — verified on the published 4.2-30b, whose config carries layer_types: ["full_attention", ...] and serves correctly. Stock Granite 4.0 hybrid-typed checkpoints (granite-4.0-micro, h-small, h-tiny) are. 4.1/4.2 bases are model_type: granite and route to granite.py, which has no such table.

Options

  • 4-line alias in our register() — ALL_DECODER_LAYER_TYPES.setdefault("full_attention", ...["attention"]). It has to go here: the crash is in vLLM's spawned engine process, and register() is our vllm.general_plugins entry point, which vLLM loads inside that process (v1/engine/core.py:105). setdefault makes it a no-op on 0.26+. Repairs the venv, not just the tests.
  • Test-only sitecustomize.py on PYTHONPATH — keeps src/ free of upstream patches, at the cost of CI plumbing.
  • xfail below 0.26 — silences the tests, leaves the serving regression.
  • Add a vLLM 0.26+ leg — the real fix. Every module and symbol we import checked clean from 0.20.2 through 0.28.0.

Needs a decision before the TurboCTC branch merges. Related: #12, #14.

Note a separate stale comparison in vllm/config/model.py's is_hybrid escape hatch (layer == "attention") is still broken in 0.28.0. We sidestep it by not declaring IsHybrid; it is worth an upstream PR on its own.

Activity

  1. added
    bug
    vllm
    dependencies
    feature/granite-turboctc-default
    prio:high
    on Sep 8, 2026
  2. added a commit that references this issue on Sep 9, 2026
    8a07b33
  3. added a commit that references this issue on Oct 5, 2026
    b7e5421
  4. added a commit that references this issue on Nov 20, 2026
    dd52aab
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Metadata

Metadata

Assignees

No one assigned

    Labels

    bugdependenciesfeature/granite-turboctc-defaultprio:highvllm

    Type

    No type

    Projects

    No projects

      Milestone

      No milestone

      Relationships

      None yet

      Development

      No branches or pull requests

      Issue actions