Skip to content

Is the maximum size of a ping packet 1436? #1836

Open

Description

@ggsnpdsn

I used the command ping -s 1436 ServerIP, which succeeded, but ping -s 1437 ServerIP failed. Does this mean that for UDP traffic, the client must manually adjust its MTU to avoid sending packets larger than 1436 bytes? Can't fragmentation be handled automatically?

Activity

  1. gruyaume commented on Oct 18, 2026

    @gruyaume
    Member

    Hi @ggsnpdsn ,

    Ella Core's datapath does not fragment, but you can change the N3 interface's MTU on the host.

  2. ggsnpdsn commented on Oct 19, 2026

    @ggsnpdsn
    Author
    1. Hi @ggsnpdsn ,
      Ella Core's datapath does not fragment, but you can change the N3 interface's MTU on the host.

    How to modify it? Is the default 1500?

  3. gruyaume commented on Oct 19, 2026

    @gruyaume
    Member
    1. Hi @ggsnpdsn ,
      Ella Core's datapath does not fragment, but you can change the N3 interface's MTU on the host.

    How to modify it? Is the default 1500?

    It depends on your host, you can check it with ip link show <n3-interface>. You can change it with ip link set dev <n3-interface> mtu <desired MTU>.

  4. ggsnpdsn commented on Oct 19, 2026

    @ggsnpdsn
    Author

    3. ip link set dev

    Modifying the MTU on n3 doesn't appear to have any effect, since the maximum ping packet size remains unchanged.

  5. ghislainbourgeois commented on Oct 23, 2026

    @ghislainbourgeois
    Collaborator

    Hi @ggsnpdsn ,

    To have a larger MTU, it will need to be changed in a different places. If you want the UEs to get a standard MTU of 1500, the N3 interface, the radios, and the networking gear in between will need to be configured for a larger MTU to account for the GTP encapsulation overhead (around 64 bytes). This would mean that the MTU for the N3 interface, radios and network in between would need to be at a minimum of 1564.

    Then, the Data Network configuration in Ella Core needs to be changed. In Networking -> Data Networks, select the right data network, and in the Configuration box, select the pen icon to edit the MTU to 1500.

    Once all of that is done, the UEs will receive the right MTU from the network, and will be able to use it.

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Metadata

Metadata

Assignees

No one assigned

    Labels

    No labels
    No labels

    Type

    No type

    Projects

    No projects

      Milestone

      No milestone

      Relationships

      None yet

      Development

      No branches or pull requests

      Issue actions