You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
Low findings of the pre-release review of 0.4.0 that concern code.
Problems
Registries missing from the startup log of token recipients.pro_tes/security.py logs "TES backends with access tokens of proTES", but leaves out service registries, whose verified TES instances get the same client-credentials token (entries default to auth: client_credentials). Operators can't see from the log that services chosen by the registry's admins get the token.
POST /tasks can outlast a 60 s proxy budget. Only the connect timeout of each forwarding attempt is cut to the time left (attempt.remaining()); the create read and the follow-up get_task each use custom.tes.timeout (15 s), plus up to 5 s to connect for the latter. With FOCA's default plugins.defaults.forward_timeout of 60 s, a request can take about 60 + 15 + 5 + 15 = 95 s, beyond the 60 s read timeout of common reverse proxies (e.g., ingress-nginx), which the docs ask to stay below. The client then gets a 504 and may create the task twice on retry.
Proposed fix
Log the registry entries (with their auth) in that line, or in one next to it.
Set plugins.defaults.forward_timeout in the base config (and so the chart) so that forward_timeout + tes.timeout + 5 + tes.timeout stays within 60 s with the defaults, and document the combined bound; test it.
Acceptance criteria
The startup log names registries whose instances get proTES' token.
A test checks that the defaults keep task creation within 60 s; docs state the bound.